COMPONENT / ELECTRO-PNEUMATIC-REGULATOR

Electro Pneumatic Regulator

Electro Pneumatic Regulator · Pneumax
Manufacturer illustration · PneumaxPictured model: Series 1700 (including 1700-2L1D0090)Original source
01 / INTRODUCTION

What is it?

A pneumatic control component continuously adjusting outputs such as air pressure in response to an electrical signal.

02 / CONSTRUCTION

Construction & recognition

Normally incorporates a regulating valve, sensing and electronic control. Input signals and feedback arrangements vary by product.

03 / APPLICATIONS

Common applications

Grip-force adjustment, tension control and process air-pressure settings.

Browse this category

Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.

ENGINEERING GUIDE

Selection and design guide

A pressure reducing valve that turns an electrical signal, 0 to 10 V or 4 to 20 mA for example, into an outlet pressure in proportion. It regulates it inside by supply and exhaust solenoid valves with a pressure sensor in a closed loop, or by a proportional solenoid. It is used where the pressure has to be changed at any time, as in tension, pressing force, dispensing and balancing. Selection looks at the pressure range, the flow, the input signal, the accuracy, the state on power failure and the upstream filtration.

01Construction and how it works

An ordinary pressure reducing valve sets its pressure by a spring turned by hand, so changing the pressure means someone turning the knob. The electro-pneumatic regulator, also called a proportional pressure regulator, replaces the spring with an electrical signal, and SMC names the part Electro-Pneumatic Regulator. The PLC gives 4 to 20 mA or 0 to 10 V, the outlet pressure follows in proportion, and the actual pressure can be fed back as an analogue or a switching signal.

The most common type on automated machines today is the pilot operated (PWM) type, the SMC ITV for example. As the input signal rises, the supply solenoid valve

  1. ①opens and the exhaust solenoid valve
  2. ②closes, supply pressure enters the pilot chamber
  3. ③and acts on the diaphragm
  4. ④. The supply valve
  5. ⑤linked to the diaphragm is pushed open, and part of the supply pressure becomes the output pressure. The output pressure is fed back to the control circuit
  6. ⑧by the pressure sensor
  7. ⑦and compared with the input signal. The circuit then either adds more air or opens the exhaust solenoid valve to release the pilot chamber, until the output pressure is in proportion to the input signal. The handbook explains that such a valve is in effect a pulse width modulated (PWM) proportional pressure valve, and that the two pilot solenoid valves are two-port two-position, or three-port, high speed valves.
Working principle of the SMC ITV series, the ITV1000 on the left and the ITV2000/3000 on the right. ① supply solenoid valve, ② exhaust solenoid valve, ③ pilot chamber, ④ diaphragm, ⑤ supply valve, ⑥ exhaust valve, ⑦ pressure sensor, ⑧ control circuit; the power supply and the input signal go to the control circuit, which provides the output signal (monitor output) and the pressure display. SUP is the supply port, OUT the output port and EXH the exhaust port
Working principle of the SMC ITV series, the ITV1000 on the left and the ITV2000/3000 on the right. ① supply solenoid valve, ② exhaust solenoid valve, ③ pilot chamber, ④ diaphragm, ⑤ supply valve, ⑥ exhaust valve, ⑦ pressure sensor, ⑧ control circuit; the power supply and the input signal go to the control circuit, which provides the output signal (monitor output) and the pressure display. SUP is the supply port, OUT the output port and EXH the exhaust portSource: SMC catalogue, Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series ITV (Best Pneumatics, English edition)
Sectional drawing of the electro-pneumatic pressure reducing valve, labelled in Chinese in the original: ⑧ the control circuit takes the power supply and the input signal and gives the output signal; ① the supply solenoid valve and ② the exhaust solenoid valve set the pressure in ③ the pilot chamber; ④ the diaphragm pushes ⑤ the supply valve open or lets ⑥ the exhaust valve release air; ⑦ the pressure sensor reads the pressure at the OUT port and feeds it back to the control circuit, and the pressure is displayed on top. The training material notes that the control signal may be an analogue 0 to 20 mA, 4 to 20 mA, 0 to 5 V or 0 to 10 V signal, or a switching signal
Sectional drawing of the electro-pneumatic pressure reducing valve, labelled in Chinese in the original: ⑧ the control circuit takes the power supply and the input signal and gives the output signal; ① the supply solenoid valve and ② the exhaust solenoid valve set the pressure in ③ the pilot chamber; ④ the diaphragm pushes ⑤ the supply valve open or lets ⑥ the exhaust valve release air; ⑦ the pressure sensor reads the pressure at the OUT port and feeds it back to the control circuit, and the pressure is displayed on top. The training material notes that the control signal may be an analogue 0 to 20 mA, 4 to 20 mA, 0 to 5 V or 0 to 10 V signal, or a switching signalSource: SMC (China), training material Pneumatic Technology Basics

Another kind is directly driven by a proportional solenoid, the moving armature type. A proportional amplifier turns the input voltage into a current in proportion, the solenoid produces a force in proportion to the current and pushes the spool of a three-port two-position valve open. The output pressure acts through a feedback passage on the bottom of the spool and balances the solenoid force, so the output pressure is in proportion to the input signal. There is also the nozzle flapper type: a piezoelectric flapper or a torque motor changes the back pressure of a nozzle and a diaphragm amplifies it, and the SMC IT600 listed in the handbook belongs to this kind.

F_f + X_0 · K_XF = F_e + ΔF; F_f = A_f · p_a; F_e = K_IF · K_UI · U_e
F_f
Feedback force of the output pressure on the bottom of the spool, N
X_0 · K_XF
Precompression of the feedback spring times its rate, that is the spring preload, N; subscript 0 for the precompression and XF for the spring
F_e
Solenoid force of the proportional solenoid, N
ΔF
Friction force, N
A_f
Area of the spool under pressure at the bottom
p_a
Pressure at output port A
K_IF
Current to force gain of the proportional solenoid; subscripts I for current and F for force
K_UI
Voltage to current gain of the proportional amplifier; subscripts U for voltage and I for current
U_e
Input voltage signal

Table 23-6-5 of part 23 of the Mechanical Design Handbook, moving armature proportional pressure valve (printed page 23-339). The handbook prints the two gains as KIF and KUI, the spring term as KXF and the precompression as X0, and here the subscripts are separated with an underscore. The handbook calls K = KIF·KUI/Af the gain, or proportional coefficient, of the valve. The expression shows two things: the output pressure is proportional to the input signal, and friction ΔF and the spring preload are sources of error, which appear on the catalogue as hysteresis and zero offset.

02Types and designation systems

Comparison of the three kinds of electro-pneumatic regulator
TypeHow it worksFeaturesExample in the sources
Pilot operated (PWM type)Two high speed solenoid valves set the pilot chamber pressure, closed loop on a pressure sensorHandbook: accuracy 0.5%~1% of full scale and response 0.2~0.5 s, suited to medium accuracy and ordinary dynamics; little air used when balanced; holds the output pressure on power failure; no nozzle, so insensitive to contaminationSMC ITV0000/1000/2000/3000
Moving armature (proportional solenoid)A proportional solenoid pushes the spool and the output pressure feeds back to balance itDirect construction and a fast responseHandbook: Norgren VP22 (direct acting, for closed loop, high accuracy and high speed duty)
Nozzle flapper typeA piezoelectric flapper or a torque motor changes the nozzle back pressure and a diaphragm amplifies itFast response and large flow; the nozzle dislikes dirtSMC IT600: input 4~20 mA, linearity ±1.0%, hysteresis 0.75%, repeatability within ±0.5%, explosion proof construction

Mechanical Design Handbook, part 23, chapter 6, section 3 several kinds of electro-pneumatic proportional and servo valve (printed pages 23-339~23-340), 5.4 SMC IT600 (printed page 23-353), 5.5 SMC ITV (printed pages 23-354~23-356) and 5.6 Norgren VP22 (printed page 23-359).

SMC examples: the flow steps of the ITV series
SeriesMaximum flow L/min(ANR)Notes
ITV00006Small, 15 mm wide and about 100 g, suited to manifold mounting; response time 0.1 s with no load
ITV1000200Ports 1/8 and 1/4; about 250 g
ITV20001500Ports 1/4 and 3/8; about 350 g
ITV30004000Ports 1/4, 3/8 and 1/2; about 645 g

SMC ITV catalogue pages 803~804 and 814~815. The maximum flow is measured at a set pressure of 0.6 MPa and a supply pressure of 1.0 MPa; the catalogue notes that the response time of the ITV0000 is not a guaranteed value. All figures are for the SMC series.

03Key parameters

SMC example: standard specification of the ITV1000/2000/3000
ItemSpecification
Set pressure range0.005~0.1 MPa (ITV□01), 0.005~0.5 MPa (ITV□03), 0.005~0.9 MPa (ITV□05)
Minimum supply pressureSet pressure + 0.1 MPa
Maximum supply pressure0.2 MPa (ITV□01); 1.0 MPa (ITV□03, □05)
Power supply24 VDC ±10%, 0.12 A or less; or 12~15 VDC, 0.18 A or less
Input signalCurrent type 4~20 mA and 0~20 mA (sinking type); voltage type 0~5 V and 0~10 V; also preset point input, digital input and bus type
Input impedance250 Ω or less for the current type; about 6.5 kΩ for the voltage type
Monitor outputAnalogue 1~5 V or 4~20 mA (accuracy within ±6% F.S.), or a switching output, NPN/PNP open collector 80 mA; one or the other
Linearity / hysteresis / repeatabilityWithin ±1% F.S. / 0.5% F.S. / ±0.5% F.S.
Sensitivity / temperature characteristicWithin 0.2% F.S. / ±0.12% F.S./°C
Pressure display accuracyWithin ±2% F.S. ±1 digit
Ambient and fluid temperature0~50 °C (no condensation)
Degree of protectionIP65

Standard specification on page 815 of the SMC ITV catalogue. The catalogue notes that these figures are static values and that the pressure on the output side fluctuates while air is being used. A custom specification with a linearity of ±0.5% F.S. is also available. In the ITV parameter table on printed page 23-356 of the handbook the linearity column reads 0.1% FS, which does not agree with the ±1% F.S. of the SMC catalogue, so this article follows the catalogue and takes ±1%.

What these accuracy figures mean: linearity is how far the output pressure departs from a straight line against the input signal; hysteresis is the difference in output between raising the pressure and lowering it to the same input signal; repeatability is the spread of the output when the same input is given again and again; sensitivity is the smallest change of input that moves the output. All are percentages of full scale (F.S.), so on a 0.9 MPa valve ±1% F.S. is ±0.009 MPa. Do not take an oversized range: where 0.5 MPa is enough, a 0.9 MPa range makes the absolute error at the same percentage nearly twice as large.

p = p_FS × s / 100
p
Output pressure, that is the set pressure, MPa
p_FS
Upper limit of the set pressure range of that model, the full scale, MPa, for example 0.5 or 0.9; subscript FS for full scale
s
Input signal as a percentage of full scale, %: on the 4~20 mA type 4 mA is 0% and 20 mA is 100%; on the 0~10 V type 0 V is 0% and 10 V is 100%

Written from the straight line relation of the input and output characteristic, Figure 1 on page 815 of the SMC ITV catalogue. The chart marks everything below 0.005 MPa as outside the control range; the catalogue also notes that the maximum set pressure differs slightly with the pressure display unit (see page 853 of the catalogue), so follow the catalogue. Example: on the 0.9 MPa type with a 4 to 20 mA input, 0.36 MPa needs s = 40%, which is 4 + 16 × 0.4 = 10.4 mA.

04Boundary dimensions and mounting space

An electro-pneumatic regulator is not large, but it needs room above and below: the signal plug and the cable are on top, the mounting bracket is underneath, and the supply, output and exhaust ports are on the sides. The SMC ITV1000/2000/3000 series with analogue input in single unit form is taken as the example, with dimensions from the SMC ITV catalogue.

Main dimensions of the SMC ITV series (mm)
ModelBody (plan view)Body height (without plug)SUP and OUT portsEXH portBase screw holesWeight
ITV1000□50 (as marked in the catalogue)711/8, 1/41/84 × M4×0.7, 6 deepabout 250 g
ITV2000□50931/4, 3/81/44 × M5×0.8, 6 deep, □36about 350 g
ITV3000□661141/4, 3/8, 1/21/24 × M5×0.8, 6 deepabout 645 g

SMC ITV catalogue page 1183 (specification and weight) and pages 1194, 1197 and 1200 (dimensions of the ITV1000, 2000 and 3000). The M12 socket adds 11 mm to the body; the SUP and OUT ports are on one axis on opposite sides of the body, and the EXH (3) port is on another side.

Dimension drawing of the SMC ITV2000 with a flat bracket (front view and side view). Left, the front view: the M12×1 socket on top, the centres of the SUP and OUT ports 19 above the bottom face of the body, the exhaust port of the M5 pilot solenoid valve 13.5 above. In the bottom face sit the 4 × M5×0.8, 6 deep screw holes (□36) for the flat bracket. Right, the side view: body height 93, the socket a further 11, bracket thickness 12, EXH port 1/4 and SUP and OUT ports 1/4 or 3/8.
Dimension drawing of the SMC ITV2000 with a flat bracket (front view and side view). Left, the front view: the M12×1 socket on top, the centres of the SUP and OUT ports 19 above the bottom face of the body, the exhaust port of the M5 pilot solenoid valve 13.5 above. In the bottom face sit the 4 × M5×0.8, 6 deep screw holes (□36) for the flat bracket. Right, the side view: body height 93, the socket a further 11, bracket thickness 12, EXH port 1/4 and SUP and OUT ports 1/4 or 3/8.Source: SMC, Electro-Pneumatic Regulator ITV1000/2000/3000 Series, page 1197
  • Mounting bracket: the flat bracket is 100 × 52 mm with four ø7 holes on an 84 × 40 mm pitch and raises the unit 12 mm; an L bracket is also available for wall mounting, with the plate reaching 45 mm to the side. The flat bracket is the same for all three sizes (pages 1194, 1197 and 1200).
  • Top plug: the M12×1 socket is in the top face. A straight cable plug leaves vertically upwards, so allow height above for the plug and the bend of the cable; a right angle plug stands about 33 mm above the body, and its cable leaves towards the SUP port (towards the EXH port on the communication type) and cannot be turned, so forcing it damages the socket (page 1226).
  • Exhaust: besides the main EXH (3) port there is a small exhaust port of the pilot solenoid valve on the front face (M3×0.5 on the ITV1000 and M5×0.8 on the ITV2000/3000), which must not be blocked. Where water or dust is present, the catalogue requires a fitting and a tube on this port to lead the air to a clean place (page 1225).
  • Piping: a rigid pipe such as steel tube passes torque and vibration into the body, so the catalogue requires a length of flexible tube in between (page 1225); fit a filter of 5 µm or finer close to the inlet (page 1224).
  • Environment: ambient and medium temperature 0 to 50 °C with no condensation, protection IP65 (page 1183); do not mount it where vibration or shock is heavy, and do not leave it in direct sun for long periods.
The signal plug, the upstream filter and the manual pressure reducing valveM12 Circular Connector →Compressed Air Filter →Air Pressure Regulator →

05Selection and calculation

  1. 1 Fix the pressure rangeChoose the range from the highest pressure the load needs: the top of the set pressure range only has to be a little above the highest pressure used, and not much more, because the accuracy is a percentage of full scale. For vacuum use an electronic vacuum regulator (SMC ITV009, ITV209 and so on).
  2. 2 Check the supply pressureThe supply pressure has to be at least 0.1 MPa above the highest set pressure used, which the SMC catalogue gives as minimum supply pressure = set pressure + 0.1 MPa, and it must not exceed the maximum supply pressure.
  3. 3 Fix the flow stepChoose the series from the air used downstream: the small flow type is enough for one small cylinder or for a pilot signal, while feeding one or more cylinders directly calls for the flow characteristic curve in the catalogue read against the cylinder consumption. With a large leak or a large flow on the output side the pressure does not reach the set value, the solenoid valves work continuously and their life is much shortened, as the SMC precautions point out. Where the flow needed is above the series chosen, the output of the regulator can be used as a pilot signal to control a large bore pilot operated pressure reducing valve, with the combination confirmed from the maker data.
  4. 4 Fix the input and feedback signalsSee whether the analogue output module of the PLC is current or voltage. Where interference is heavy or the cable is long, prefer 4~20 mA. To confirm that the pressure has arrived, take the analogue monitor output; where only reached or not reached matters, take the switching output. With many points already on a bus, take the bus or IO-Link type.
  5. 5 Decide what happens on power failure and on air failureDecide whether the outlet pressure should be held or vented on a power failure or an emergency stop, and fit a residual pressure release valve or a shut-off valve as set out under installation and use below.
  6. 6 Provide the upstream filterFit an air filter of 5 µm or finer on the supply side, add a dryer where there is much condensate, and do not fit a lubricator upstream of the regulator.
Where the regulator controls a pressing or clamping force, work out the pressure needed with the cylinder bore calculator first and then choose the range of the regulator from that pressureUse the unit conversion tool to convert between MPa, bar and kPa
Typical applications
ApplicationMethodSource
Tension controlThe controller gives a current from the tension signal and the regulator turns it into brake (reel) pressure to hold the tension of the materialHandbook, IT600 application b
Rolling and pressing force controlA pressure sensor feeds the measured pressure back to the controller, which signals the regulator so that the cylinder gives an accurate rolling forceHandbook, IT600 application c
Several pressure steps turned into analogue controlWhere several reducing valves and solenoid valves used to switch between pressure steps, one regulator takes different signalsSMC ITV catalogue, application
Electrostatic painting and dispensingThe supply pressure of the paint or the adhesive is controlled, and with it the quantity deliveredSMC ITV catalogue, application
Thrust managementAn alarm is raised when the set pressure is not reached or not held within a set time (5 s in the SMC custom specification example)SMC ITV catalogue, custom specification
Balancing and constant forceThe cylinder pressure is adjusted with the load to give a suspended balance or a constant contact forceApplied from the pressure control principle above

Mechanical Design Handbook, table 23-6-11, IT600 applications (printed page 23-354); SMC ITV catalogue page 804 (applications) and page 837 (custom specification, thrust management alarm).

06Installation, wiring and use

  • Upstream filter: fit an air filter of 5 µm or finer on the supply side close to the valve; where there is much condensate add an aftercooler, a dryer or a drain; carbon dust from the compressor collects inside the valve and causes faults (SMC precautions).
  • Do not fit a lubricator on the supply side, which causes faults; where the end equipment needs lubrication, fit the lubricator downstream of the regulator.
  • One power supply per regulator. SMC states that the power ground and the signal ground are one common terminal, so several regulators on one supply may carry stray currents and work incorrectly.
  • Against interference: fit a line filter on the AC supply, keep the regulator and its wiring away from motors and power cables, and add surge protection to inductive loads such as solenoid valves and relays.
  • Exhaust silencing: with a large volume on the output side, or when the valve works as a relief valve, the exhaust is loud, so fit a silencer on the EXH port.
  • Damp and dusty places: water and dust may enter the breather hole and the exhaust port, so lead the breather to a clean place with a fitting and a thin tube, without kinking or blocking the tube.
  • Piping: blow the swarf and seal material out of the pipe first and leave 1.5 to 2 threads of tape; hold the female port side when tightening; where a rigid pipe such as steel tube is used, put a length of flexible tube in between so that torque and vibration do not reach the body.

07Failure modes and maintenance

Common faults, causes and remedies
SymptomProbable causeAction
The pressure does not reach the set value and the valve buzzes all the timeSupply pressure too low, below the set value plus 0.1 MPa, or leakage or too much air used on the output sideRaise the supply pressure; look for leaks; change to one size up by the flow
The output pressure fluctuates widelyAir is drawn downstream all the time, while the catalogue accuracy is a static value, or the range chosen is too largeAdd a small air receiver downstream or change to pilot control; change to a suitable range
There is still pressure with the setting at 0Below 0.005 MPa the valve cannot controlFit a three-way valve on the output side to release the residual pressure
The output is not controlled and occasionally jumpsStray current through a common power ground, interference, or wrong wiringOne supply per unit; add a filter and surge protection; check the wiring
Slow response and poorer accuracyDirty or oily air has contaminated the internal solenoid valves and the sensorFit a 5 µm filter and remove the upstream lubricator; the internal solenoid valves are wearing parts and need regular service in frequent use
The downstream pressure falls away slowly after the power is cutHolding on power failure is only temporary and is not guaranteedAdd a check valve or another means of holding pressure in a circuit that needs it

Compiled from the product precautions in the SMC ITV catalogue (pages 849~851).

08Common design mistakes

  • Expecting it to hold pressure on power failure. Holding is only temporary and is not a designed function. A circuit where losing pressure matters, such as clamping or lifting, needs a check valve or a mechanical lock.
  • Expecting it to vent on power failure. The opposite is true: it holds the pressure for a time when the power fails, and with the supply on and no power the output may rise to the supply pressure. To vent, fit a residual pressure release valve or a three-way valve, and cut the air supply when the machine is not running.
  • Choosing too large a range. A 0.2 MPa dispensing pressure on a valve with a 0.9 MPa range makes ±1% F.S. equal to ±0.009 MPa, a relative error of about 4.5%.
  • Fitting a lubricator upstream. The oil contaminates the internal solenoid valves and the sensor.
  • Setting the supply pressure exactly at the set pressure. The minimum supply pressure is the set pressure plus 0.1 MPa, so with too little supply the pressure will not rise and the valve keeps adding air.
  • Using it straight on a large flow. Read the flow characteristic in the catalogue first; with a large flow the output pressure drops and the valve life is short.
  • Running several regulators from one power supply. SMC requires one supply per unit, or the signal is disturbed.
Related parts: manual pressure reducing valve, precision air regulator, compressed air filter, pressure sensor and pressure switch, air preparation unitAir Pressure Regulator →Precision Air Regulator →Compressed Air Filter →Pressure Sensor And Switch →Air Service Unit →

09Standards and manufacturer ranges

  • No national product standard number for the electro-pneumatic regulator was found in the sources used. The degree of protection is stated to IEC 60529, and the SMC ITV is IP65.
  • SMC: ITV0000 (small), ITV1000/2000/3000 (standard), ITV009/209 (electronic vacuum regulator), IT600 (nozzle flapper electro-pneumatic converter, explosion proof); bus and IO-Link types of the ITV are also available.
  • Norgren: VP22 three-port two-position direct acting proportional pressure valve (handbook part 23, chapter 6, section 5.6).

—Sources

  • SMC catalogue, Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series ITV (Best Pneumatics, English edition) ↗Catalogue pages 803~804 series overview and applications; 815 ITV1000/2000/3000 standard specification and input/output characteristic; 817 working principle; 836~837 custom specifications; 849~851 product precautions (filtration, lubricator, power failure and air failure, no shut-off function, power supply, interference)
  • SMC (China), training material Pneumatic Technology BasicsPage 41: pressure reducing valve, electro-pneumatic type (product photograph, sectional drawing, kinds of control signal)
  • Mechanical Design Handbook, part 23 Pneumatic transmission, chapter 6 Electro-pneumatic proportional and servo valvesPrinted pages 23-339~23-340: table 23-6-5 principles and balance of nozzle flapper, moving armature and PWM pilot operated proportional pressure valves; printed pages 23-353~23-356: SMC IT600 and ITV principles, parameters and applications; printed page 23-359: Norgren VP22
  • SMC, Electro-Pneumatic Regulator ITV1000/2000/3000 Series catalogue ↗Page 1183 specification (temperature, protection, weight); pages 1194, 1197 and 1200 dimensions of the ITV1000/2000/3000 and brackets; pages 1224~1226 usage notes (filtration, piping, exhaust port, right angle plug direction)

Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-25

ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN

Buying and using: calculators, sellers, uses

The notes below cover the “Valves & valve islands” category. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.

TOOLS / CALCULATE

Related selection calculators

Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.

07 / SELLERS

Who sells it

The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. Price comparison and ranking are not available yet.

Corresponding series by manufacturer

ManufacturerSeriesOfficial product page
SMCITVOpen product page
FestoVPPMOpen product page
AirTACGPVTOpen product page

Representative series and official product pages; a manufacturer may offer other suitable series. Product ranges, availability and applicability are governed by manufacturer information. This is not a ranking, recommendation or equivalence judgment.

08 / WHERE IT IS USED

Typical uses & where it sits in machines

Grip-force adjustment, tension control and process air-pressure settings.

Profile frameElectric linear moduleShock absorberGuided cylinderCylinder switchSpeed controllerAir tubingRotary actuatorParallel gripperVacuum cupVacuum generatorVacuum switchFRL unitHere: Valves & valve islandsValve island
Pick-and-place unit (electric traverse, pneumatic lift and grip)Schematic, not to scaleArrow: Valve island
Directional control of cylinders and grippersCentralised control of several actuators (valve islands)Manual and foot-operated fixturingProportional tension and pressure control, and soft starting

Equipment breakdowns on this site that use this component family: