01 / INTRODUCTION
What is it?
A positive-displacement compressor that uses a meshing male and female rotor pair to shrink the space between threads and deliver air continuously at network pressure.
02 / CONSTRUCTION
Construction & recognition
In oil-injected units the male rotor usually drives the female rotor directly, and oil sprayed into the chamber cools, seals and lubricates; oil-free units use external timing gears to hold rotor phasing so the rotors never touch, usually in several stages with interstage cooling. Each stage has a fixed built-in pressure ratio set by rotor length, pitch and discharge port shape, and must match the working pressure.
03 / APPLICATIONS
Common applications
General plant air, automotive and electronics manufacturing, oil-free air for food and pharma, purging and pneumatic conveying.
Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
A pair of male and female rotors compresses air continuously, and this is the main air source of a factory, in oil-injected and oil-free forms. Selection fixes the free air delivery (FAD) from the air demand plus a margin, and the discharge pressure from the end-of-line pressure plus the pressure losses. It then looks at the specific power, the control method (load/unload or variable speed), the air receiver, the pressure drop of the pipe network, the cooling and the heat recovery.
01Construction and how it works
Inside the screw element a pair of counter-rotating male and female rotors mesh, the space between the lobes shrinks along the axis as they turn, and the air is compressed continuously. Section 2.1.5 of the Atlas Copco Compressed Air Manual (the Manual below) states that every element has a built-in pressure ratio set by the rotor length, the lead and the shape of the discharge port, and that the efficiency is highest when this matches the actual working pressure. A screw machine has no inlet or discharge valves and no unbalanced reciprocating mass, so it can run fast, with a large delivery in a small envelope.
Flow through an oil-injected screw compressor (Manual figure 2:9): air passes the air intake filter and the air intake valve (the valve that load/unload works by opening and closing) into the compressor element. There it is compressed together with the injected oil and enters the oil separator vessel. The separated oil returns to the element through the thermostatic bypass valve, the oil cooler and the oil filter. The compressed air leaves through the minimum pressure valve, the after-cooler and the water separator with drainSource: Atlas Copco, Compressed Air Manual, 9th edition
Oil-injected screw: oil is injected into the compression chamber for cooling, lubrication and sealing, the male rotor drives the female rotor directly and there is no timing gear. Manual 2.1.5.2: a single stage reaches 14 bar, even 17 bar, but the efficiency falls as the pressure rises; section 3.2.3: a modern oil-injected machine leaves less than 3 mg/m³ of oil in the discharge (20 °C). Oil-free screw: the two rotors are kept in phase and clear of each other by external timing gears, so the compression chamber runs dry; the built-in pressure ratio is limited by the temperature difference between inlet and discharge, which is why two stages with intercooling are common.
Flow through an oil-free screw compressor (Manual figure 2:10): suction filter → suction valve → first stage compressor element → intercooler → water separator → second stage compressor element → non-return valve → after-cooler → water separator. The intercooling between the stages holds down the discharge temperature of each stageSource: Atlas Copco, Compressed Air Manual, 9th edition
Main parts of the package and what to watch in the design
Part
Function
What to watch in the design
Intake filter, intake valve
Removes dust; fully open when loaded, closed when unloaded
The intake air has to be clean and cool; add a prefilter in dusty places and count its pressure drop in the design
Compressor element
Compresses the air
An oil-injected machine reaches 14~17 bar in one stage; oil-free machines are mostly two stage
Oil separation and oil circuit (oil-injected machines)
Separates the oil, cools it and returns it
The discharge still carries a trace of oil, so add an oil removal filter where the air quality requirement is high
After-cooler, water separator
Cools the discharge to about 10 °C above the cooling medium and takes out 80%~90% of the condensate
The condensate contains oil, so it goes through an oil-water separator before discharge
Motor and starter
Direct-on-line, star-delta or soft start; a variable speed model includes the drive
Supply capacity, cable and protection to the catalogue; derate for altitude and high temperature
Controller
Load/unload, start/stop, variable speed, group control
Several machines are run together from a central controller
Compiled from Manual 2.1.5, 2.4.1.1, 3.2.6~3.2.8 and 3.7. The figures of about 10 °C above the cooling medium and 80%~90% separation are the typical values given by the Manual.
From table 23-2-1 of part 23, chapter 2, of the Mechanical Design Handbook (printed page 23-31).
Screw machine against piston machine (handbook table)
Type
Output pressure MPa
Delivery m³/min
Power kW
Vibration and noise
Discharge
Piston
1.0
0.1~30
0.75~220
High
Intermittent discharge, an air receiver is needed
Screw
1.0
0.2~67
1.5~370
Low
Continuous discharge, and the air can be oil-free
From table 23-2-1, comparison of characteristics, of the Mechanical Design Handbook (printed page 23-33). Where the handbook says a screw machine needs no receiver it means the discharge does not pulsate; section 3.6.1.1 of the Manual (Atlas Copco) requires a receiver in every compressor station, and a load/unload machine must have one sized by the formula below, so the Manual governs.
Comparison of control methods
Method
How it controls
Pressure band
Energy features
Where it suits
Load/unload
At the upper pressure the intake valve closes and the machine unloads to atmosphere, at the lower pressure it loads again
0.3~1 bar
Running unloaded still takes 15%~30% of full load power (KAESER material takes 20%)
Most common, machines above 5 kW
Start/stop
The motor stops at the upper pressure and starts again at the lower
Needs a wide band or a large receiver
No idle running, but the number of starts is limited by the motor
Small machines below 5~10 kW
Inlet throttling
The intake valve is closed down
Small
KAESER: 90% of the power is still needed at 50% delivery, so it is not recommended
Little used now
Variable speed
The motor speed follows the pressure
±0.1 bar
KAESER: best run in the 40%~70% load range; a 90 kW motor falls from 94% to 86% efficiency between 30% and 100%
Where the demand swings widely, as the trimming machine
Group control
A central controller hands out start/stop and load/unload by pressure
±0.2 bar
A base load and trimming combination cuts idle running
A compressor room with several machines
Pressure bands and unload power from Manual 2.5.1, 2.5.2.4, 2.5.2.5, 2.5.4.3 and 2.5.7; throttling, variable speed efficiency and the best load range from the chapter Efficient compressor control in the KAESER Compressed Air Engineering. The same chapter warns that a compressor below 50% load is a signal of serious energy waste, and that many machines log running hours only and not loaded hours.
Air-cooled and water-cooled
Item
Air-cooled
Water-cooled
Where the heat goes
The ventilation air takes away close to 100% of the motor input
The cooling water takes about 90%; part still has to leave the room (Manual about 10%, KAESER about 20%)
Demand on the room
A large ventilation flow, so the inlet and outlet openings have to be big
A small ventilation flow, but a cooling water system is needed
Cooling water
None
A closed system uses softened water, cooled to about 5 °C above the cooling medium; an open cooling tower needs water treatment and frost protection
Heat recovery
The warm air can heat the workshop directly
The hot water can feed space heating or domestic hot water
From Manual 3.3.1, 3.3.2 and 3.5.5; the figure of about 20% from the KAESER section Compressed air station ventilation. The two sources differ on the heat rejection share of a water-cooled room, so check against the heat rejection of the chosen model in its catalogue.
03Outline, ports and mounting space
A screw compressor is bought as a package. What the designer has to settle is how much floor the unit takes, how much service space is left around it, how the cooling air comes in and goes out, where the air outlet and the drains are, and where the power enters. The Atlas Copco GA series is the reference below. Units of the same power are roughly alike in outline, but the air flow direction and the outlet position differ widely, so a change of make has to be rechecked against that maker's catalogue.
Outline dimensions of Atlas Copco GA oil-injected screw compressors (L×W×H, mm, series examples)
Series
Power kW
Standard
Full feature (with refrigerated dryer)
Noise dB(A)
GA 7-15 VSD+
7~15
630 × 610 × 1420
630 × 985 × 1420
62~64
GA 18-37 VSD+
18~37
780 × 811 × 1590
780 × 1273 × 1590
67
GA 90+-160+ (air-cooled)
90~160
2600 × 2000 × 2000
3200 × 2000 × 2000
To the catalogue
GA 90+-160+ (water-cooled, full feature included)
90~160
2600 × 1630 × 2000
As left
To the catalogue
GA 110-160 VSD (air-cooled)
110~160
3200 × 2000 × 2000
3800 × 2002 × 2347
To the catalogue
GA 75-110 VSD+ full feature (installation drawing)
75~110
—
about 1300 × 2179 (plan)
To the catalogue
The first five rows are from the Dimensions tables on the GA 7-37 VSD+ and GA 90+-160+ pages of the Atlas Copco General catalog for compressed air, gas and vacuum solutions; noise is the average sound pressure level at 1 m (ISO 2151), the GA 7-37 VSD+ page gives 62 dB(A) as the lowest and states that the unit can stand against a wall or even in a corner. The last row is read from the maker's installation proposal drawing (download link in this section). The GA 30+-90 catalogue gives weights only (for example about 1229 kg for the GA 55 and about 1425 kg for the GA 90), so the outline dimensions follow the catalogue.
Connections and installation requirements (GA 75-110 VSD+ installation proposal and the Manual)
Item
Requirement
Floor
Level and able to carry the weight of the unit; in a new compressor room give each unit a plinth so that the floor can be cleaned (Manual 3.5.3)
Discharge pipe
Connected free of stress; below DN100 use a flexible hose to isolate vibration, above DN100 an axial compensator (KAESER)
Inlet air
Inlet air temperature 46 °C maximum and 0 °C minimum; face velocity at the inlet louvre ≤5 m/s; the inlet must not draw in the hot discharge air
Discharge duct
Permitted pressure drop across the unit 30 Pa; the dryer air and the oil cooler and after-cooler air go in separate ducts
Inlet humidity
Maximum relative humidity: 100% at 35 °C, 70% at 40 °C and 30% at 46 °C
Drains
The drain pipes of the units must not be interconnected before they reach an open collector, and no pipe end may dip into water; oily condensate goes through an oil-water separator
Power supply
Cable size to the maker's technical data; use proper cable glands to keep the ingress protection; consult the maker on an IT network
Heat recovery
The unit has a prepared energy recovery connection, its position per the installation proposal, and the water circuit is connected separately
In front of the control cabinet
At least 1200 mm of service space in front of the control cabinet (Manual 3.5, figure 3:28)
Unless noted, from items 1~13 of MAIN COMPONENTS on the Atlas Copco GA 75-110 VSD+ installation proposal.
Q_v = (1.06 · N + 1.2 · D) / ΔT
Q_v
Cooling ventilation flow needed for the compressor room, m³/s; subscript v for ventilation
N
Rated power of the compressor motor, kW
D
Electrical power of the dryer, kW
ΔT
Permitted temperature rise in the compressor room, °C
Item 4 of the Atlas Copco GA 75-110 VSD+ installation proposal (ventilation schemes 1 and 3, heat removed by a room extract fan). Schemes 2 and 4 use a duct straight out, and the extract fan has to match the unit fan flow at the duct pressure drop. The general formula of Manual 3.5.5 is in Selection and calculation.
Electrical: Manual 3.7 — a low voltage motor is used up to about 450~500 kW, and above that a high voltage motor; direct-on-line starting draws 6~10 times the rated current, star-delta brings both current and torque down to about 1/3, and soft starting draws about 3 times; motors are selected for 40 °C and 1000 m and derated beyond that; IP55 is the recommended protection.
Size of the ventilation openings: the KAESER rule of thumb is 0.02~0.03 m² of clear opening per kW; louvres, weather hoods and filter screens cut the clear area by 30%~60%, and that has to be made up.
Ventilation method: the KAESER material splits it by power — natural ventilation only below 5.5 kW, a room extract fan from 5.5~11 kW, and a duct straight out above 11 kW; a direct duct allows the extract to be about 20 K above ambient, while a room extract fan has to hold the room rise to 7 K.
Noise: follow the catalogue (GA 7-37 VSD+ 62~67 dB(A), GA 30+-90 65~74 dB(A), at 1 m, ISO 2151).
Catalogue and installation drawing downloads (maker websites)
Delivery FAD (referred to inlet conditions); the catalogue prints V1
V_2
Volume flow measured at the discharge; the catalogue prints V2
p_1, T_1
Inlet pressure (absolute) and inlet temperature, K; the catalogue prints p1 and T1
p_2, T_2
Discharge pressure (absolute) and discharge temperature, K; the catalogue prints p2 and T2
p_D
Saturation vapour pressure of water at the inlet temperature
F_rel
Relative humidity of the inlet air
Figure 1 of chapter 1 of the KAESER material, corresponding to the measurement method of ISO 1217 annex C (DIN 1945 part 1 annex F). The designer does not have to measure it, but has to understand that FAD is a volume of air at inlet conditions and is not the same thing as Nm³ at standard conditions (0 °C, 1.013 bar).
P_spec = P_el / FAD
P_spec
Specific power, kW/(m³/min); subscript spec for specific
P_el
Total electrical power of the package at the maximum working pressure (main motor, fan, oil pump, auxiliary heaters and every other consumer), kW; subscript el for electrical
FAD
Delivery at the same pressure, m³/min
Item 4 of chapter 1 of the KAESER material: for an economic comparison the specific power has to be taken for the whole package at the maximum working pressure. China also has an energy efficiency standard that grades positive displacement compressors by specific power, so ask the supplier for the efficiency label and the specific power of the model; the standard number and the limits of each grade follow the current national standard.
Effect of altitude and ambient temperature on the motor (permitted load as % of rated power)
Altitude m
<30 °C
30~40 °C
45 °C
50 °C
55 °C
60 °C
1000
107
100
96
92
87
82
2000
100
94
90
86
82
77
3000
92
86
82
79
75
70
4000
82
77
74
71
67
63
From table 3:7 of Manual 3.1.3 (printed page 71), guide values for a standard motor. The same section gives an example: a compressor with a pressure ratio of 8.0 at sea level has 11.1 at 3000 m, so at altitude either the working pressure comes down or the motor goes up. The catalogue governs for a particular model.
05Selection and calculation
The steps below follow the worked examples of chapters 3 and 5 of the Manual, with the formulas of the Chinese Mechanical Design Handbook given alongside; the two lines of thought agree.
List the air demandList the consumption and the duty factor of each consumer (tools, cylinders, blow-off, air built into a machine), then add leakage, wear and future expansion. The Manual example adds 10%~20%; the Mechanical Design Handbook uses a correction factor k = 1.3~1.5. Bring everything to FAD (inlet conditions), converting any Nm³.
Fix the discharge pressureThe highest working pressure plus the pressure drop of the filters, the dryer and the pipe network and the control band of the compressor itself. Every 1 bar of extra pressure costs power, so raise the pressure of a single high pressure consumer on its own rather than the whole plant.
Choose the model and the number of machinesA fixed speed machine carries the base load and a variable speed machine trims the swing; with only one machine, leave a connection for a temporary unit.
Size the air receiverA load/unload machine needs the minimum receiver volume from the formula below; where a consumer draws a large flow for a short time, put another receiver near it.
Fix the pipe networkA ring main, with the bore checked against the permitted pressure drop and the fittings counted at their equivalent length.
Check the compressor roomVentilation flow (or cooling water flow), service space, drainage and noise; assess heat recovery.
p_c = p + ΣΔp; q_c = k · q_b
p_c
Compressor output pressure, MPa; subscript c for compressor
p
Highest working pressure of the pneumatic actuators, MPa
ΣΔp
Total pressure loss of the pneumatic system, usually 0.15~0.2 MPa
q_c
Compressor intake flow, m³/min (standard conditions); subscript c for compressor
q_b
Flow supplied to the system: the maximum consumption without a receiver, the average consumption with one; subscript b for base
k
Correction factor (leakage, simultaneity, expansion), usually 1.3~1.5
Table 23-2-1, selection calculation, of part 23 of the Mechanical Design Handbook (printed page 23-33).
How the working pressure is made up (Manual worked example)
Item
Pressure drop / pressure bar
End consumer
6
Final filter
0.1~0.5
Pipe network
0.2
Dust filter
0.1~0.5
Dryer
0.1
Compressor control band
0.5
Compressor maximum working pressure
7.0~7.8
From Manual 3.1.1.1 (printed page 67). A filter pressure drop grows as it blocks, so count the drop at the point of replacement.
Temperature of the compressed air in the receiver, K; printed T0
p_U − p_L
Difference between the load and unload set pressures, bar
f_max
Maximum loading frequency, taken as once every 30 s for Atlas Copco units; subscript max for the maximum
Manual 3.6.1.1 (printed pages 90~91). It applies only to a load/unload compressor; with several machines, work it out for the largest one.
V = q · t / (p_1 − p_2) = L / (p_1 − p_2)
V
Air receiver volume, L
q
Air consumption during the draw-off, l/s
t
Duration of the draw-off, s
p_1, p_2
Normal pressure of the network and the lowest pressure the consumer allows, bar; printed p1 and p2
L
Air to be made up in each working cycle during the charging phase, L
Manual 3.6.1.1, for the case where the compressor is chosen on average demand and a short large draw comes from the receiver; the air the compressor supplies during the draw-off is not counted. Table 23-2-5 of the Mechanical Design Handbook (printed page 23-36) gives similar formulas for two cases, holding time after a power failure and maximum consumption.
Δp = 450 · q_c^1.85 · l / (d⁵ · p)
Δp
Pressure drop in the straight pipe, bar
q_c
Air flow FAD, l/s
l
Pipe length (including the equivalent length of the fittings), m
d
Pipe bore, mm
p
Absolute pressure at the start of the pipe, bar(a)
Manual 3.6.3 (printed page 92). Turned round, l = Δp · d⁵ · p / (450 · q_c^1.85) gives the permitted pipe length (section 3.6.1). Fittings enter at their equivalent length. In the handbook example of section 5.8 an elbow with a bend radius equal to the bore counts as 1.3 m on an 80 mm pipe. There 23 m of straight pipe with 8 elbows, at 140 l/s and 8 bar(a), gives a pressure drop of about 0.0054 bar. The KAESER material multiplies the straight length by 1.6 as the flow length in the early planning stage.
How the pressure drop of the network is split
Part
Atlas Copco Manual bar
KAESER material bar
Main (riser)
0.02
0.03
Distribution pipe
0.05
0.03
Branches, connection to the consumer
0.03
0.04
Fixed network, total
0.10
0.10
Dryer
Counted separately
0.20
Filter regulator lubricator and hoses
Counted separately
0.50
Total drop from the compressor to the consumer
—
≤0.80, not more than 1
Atlas Copco from Manual 3.6.1 and 3.6.3; KAESER from the section Designing and installing a new compressed air distribution network in the Compressed Air Engineering. Both take 0.1 bar for the fixed network; the drop at hoses and push-in fittings is often the largest, so check it separately.
q_v = P_v / (1.21 · ΔT)
q_v
Ventilation flow, m³/s; subscript v for ventilation
P_v
Heat flow into the room, kW (an air-cooled unit gives up nearly all the motor input, a water-cooled unit about 10%)
ΔT
Permitted room temperature rise, °C (the Manual suggests 7~10 °C)
Manual 3.5.5 (printed page 87). The same section: the inlet air velocity is not to exceed 4 m/s, the inlet should be as low as possible and the extract fan high on the opposite wall.
W = [(K_1 · Q_1) + (K_2 · Q_2)] · T_R; W_saved = W · e_p / η
W
Energy that can be recovered per year, kWh
Q_1, Q_2
Cooling power available when loaded and when unloaded, kW; printed Q1 and Q2
K_1, K_2
Share of the heat demand time that the compressor spends loaded and unloaded; printed K1 and K2
T_R
Hours per year for which heat is needed, h; printed TR, subscript R for recovery
e_p
Energy price; subscript p for price
η
Efficiency of the existing heat source (boiler and the like)
W_saved
Heat energy saved per year, kWh (subscript saved for saved)
Manual 3.4.2 (printed page 81). The Manual: a large oil-free machine can recover up to about 94% as 90 °C hot water, while an oil-injected machine gives water at only 50~60 °C; water circuit recovery suits units above 10 kW and usually pays back in 1~3 years. The KAESER material: in an oil-injected machine about 76% of the heat is in the oil and about 15% in the compressed air, a fully enclosed unit can recover about 96% in total, the water reaches 70 °C, and heat recovery on a unit above 7.5 kW generally pays back within two years. W_saved in the second part is the annual saving in energy cost.
Put the machines in one compressor roomManual 3.5: a separate compressor room is preferred, for noise, ventilation, heat recovery and keeping unauthorised people away; the room needs lifting gear or fork lift access, floor space for a unit added later, and a floor drain.
Intake air and ventilationDraw the intake from cool outdoor air, away from vehicle exhaust, dust and corrosive gas; put the inlet in the lower part of an outside wall on the shaded side; in winter a thermostatic damper leads warm air back into the room and the room stays at +3 °C or above (KAESER).
PipeworkA flexible connection at the unit outlet; a collecting main inside the room, with each unit and the dryer connected from above; the main in the wet zone falls at 2‰ to the drain point, a drain trap sits at the low point, and branches leave from the top or the side of the main (KAESER).
Air receiverIn a frost-free room on a firm level floor, with a safety valve; drain the condensate every 8 h (at least once a day); never weld on the receiver or modify it (Manual 3.5.6).
CondensateBall valves before and after the drain trap make it easy to take off for checking; the drain pipe falls to the collector and runs unpressurised; drains at different pressures are not combined; oily condensate goes through an oil-water separator before discharge.
Running checksWatch the loaded hours as a share of the total and the number of load/unload cycles per hour; frequent cycling means the receiver is too small or the pressure band too narrow; when the discharge temperature rises, check the ventilation and the cooler first.
07Failure modes and maintenance
Common problems, causes and actions
Symptom
Main cause
Action
High discharge temperature alarm
Not enough room ventilation, hot air returning, a blocked cooler, inlet temperature above the limit
Check the flow against the ventilation formula, clean the cooler, keep inlet and discharge air apart
Not enough pressure at the consumer
Bore too small, a large drop at hoses and push-in fittings, a blocked filter, too little delivery
Check the network against the pressure drop formula, change the element, and only add a machine after the leaks are found
Frequent load/unload cycling
Receiver too small, load/unload band too narrow
Check the receiver volume against the formula, or change to a variable speed machine for trimming
Load factor below 50% for long periods
The unit is oversized and idles a lot
Add a small or variable speed machine for trimming and use group control
Water in the pipe network
Too little dryer capacity or a failed dryer, a blocked drain trap
Check the dryer against the worst case, service the drain trap
High oil consumption and oil in the discharge (oil-injected machine)
Spent oil separator element, oil level too high
Change the separator element and fill to the instruction book
Motor overload at altitude
No derating for altitude
Check the motor against table 3:7, and if necessary lower the pressure or fit a larger motor
Compiled from chapter 3 of the Manual, the KAESER Compressed Air Engineering and the Atlas Copco GA installation proposal. The service intervals of the unit's instruction book govern.
Energy saving in maintenance comes down to finding leaks, lowering the pressure and cutting idle running. Manual 2.5.1 puts energy at about 80% of the life cycle cost of compressed air; the KAESER material points out that many units display running hours only and not loaded hours, so read the load factor from the controller at intervals.
08Common design mistakes
Comparing the block delivery, or a flow at standard conditions, as FAD. The FAD in a catalogue is the delivery of the whole package at inlet conditions, so Nm³ has to be converted, or the figure comes out short.
Raising the pressure of the whole plant for one consumer. Higher pressure costs power, and once the demand falls the end pressure rises again; boost the high pressure point on its own, or put a receiver beside it.
A load/unload machine with no receiver. A receiver that is too small gives frequent cycling, a short life for the motor and the intake valve, and too much idle running.
Sizing the network on the straight pipe length only. The equivalent length of elbows and valves, and the drop at hoses and push-in fittings, is often larger than that of the straight pipe.
An air-cooled unit shut in a small closed room. Nearly all the motor power turns into heat, and without enough ventilation the unit trips on high temperature; a water-cooled unit still has some heat to remove.
Each machine on its own pressure switch, with the bands stacking up. The plant band widens and the average pressure sits too high; use a central controller instead.
Condensate straight to the sewer. The condensate of an oil-injected machine contains oil and has to go through an oil-water separator.
Using a sea level catalogue for a high altitude project. Delivery, pressure ratio and motor capacity all have to be corrected for altitude.
09Standards and manufacturer ranges
Related standards
Standard
Content
Source
ISO 1217 (annex C / E)
Acceptance tests for positive displacement compressors, delivery measurement
Chapter 1 of the KAESER material; Atlas Copco general catalogue
DIN 1945 part 1 annex F
Delivery measurement (corresponding to ISO 1217 annex C)
Chapter 1 of the KAESER material
ISO 8573-1:2010
Compressed air quality classes (particles, water, oil)
Manual 3.2; table 23-3-1 of the Mechanical Design Handbook
ISO 2151
Compressor noise measurement
Atlas Copco general catalogue
IEC motor efficiency classes IE1~IE4
Motor efficiency grading
Chapter 1 of the KAESER material
GB 150-2011
Stationary pressure vessels (air receivers)
Listed in the references of the Mechanical Design Handbook
The current edition of each applies. The Chinese energy efficiency standard for positive displacement compressors grades by specific power, and its number and limits follow the current national standard.
Atlas Copco: GA / GA+ fixed speed oil-injected screw, GA VSD / GA VSD+ variable speed oil-injected screw; the oil-free ZR / ZT series, which the general catalogue describes as available with toothed and screw elements and with air or water cooling.
KAESER: the complementary products listed in the material are the SECOTEC refrigerated dryer, HYBRITEC combination dryer, AQUAMAT oil-water separator, ECO-DRAIN electronic drain and AIRCENTER packaged station.
Other makes follow their own catalogues.
—Sources
Atlas Copco, Compressed Air Manual, 9th edition (English edition) ↗2.1.5 Twin screw compressors (printed pages 34~37, figures 2:9 and 2:10); 2.4.1.1 after-cooler; 2.5 control (printed pages 52~61); 3.1 compressor station design (working pressure, air demand, altitude, table 3:7); 3.2 air treatment; 3.3 cooling systems; 3.4 energy recovery (printed pages 79~84); 3.5 the compressor room (printed pages 84~89); 3.6 pipe network and air receiver (printed pages 90~94); 3.7 electrical installation; chapter 5 worked example (printed pages 116~125)
KAESER, Compressed Air Engineering - Basic principles, tips and suggestions (English edition) ↗Fundamentals of compressed air production (FAD, specific power, IE motors); Efficient compressor control; Energy savings with heat recovery; Designing and installing a new compressed air distribution network (pressure drop split, 1.6 times flow length); Efficient compressor station cooling and Compressed air station ventilation (ventilation method, opening area); Pipework in the compressed air station
Mechanical Design Handbook, part 23 Pneumatic transmission, chapter 2 Compressed air stations, pipe networks and productsTable 23-2-1 classification, working principle and selection calculation of air compressors (printed pages 23-31~23-33); table 23-2-5 air receivers (printed page 23-36); chapter 3 table 23-3-1 DIN ISO 8573-1 air quality classes (printed page 23-58)
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-18
Compresses ambient air and delivers it to the compressed-air network.
Operating principle
Two meshing helical rotors move air axially through chambers formed between the rotor grooves and housing. Chamber volume decreases until the air reaches the discharge end. Oil-injected compressors use oil for cooling and sealing and separate it from the discharge air.
Process sequence
Filter the inlet air
Load the compressor and draw in air
Compress the air with the rotors
Separate and cool the discharge
Supply air and regulate output by pressure
Key inputs
Demand pressure and air consumption profile
Air quality and oil content requirements
Ambient temperature and heat rejection
Common issues
For low pressure, check demand and leakage before diagnosing air-end damage.
If discharge temperature is abnormal, check cooling and lubrication.
Scope and limitations
Oil-injected and oil-free compressors have different air paths.
Provide downstream drying and filtration as required.
Functional modules
Intake filter and inlet valve
Filter incoming air and regulate loading.
Screw air end
Compresses the air as the chamber volume decreases.
Drive and supports
Drive the rotors and maintain their working clearances.
Separation and cooling circuit
Cools and treats the discharge as required for the oil-injected or oil-free design.