COMPONENT / ELBOW-SPEED-CONTROLLER

Elbow Speed Controller

Elbow Speed Controller · SMC
Manufacturer illustration · SMCPictured model: AS2201F-02-08SAOriginal source
01 / INTRODUCTION

What is it?

A pneumatic component combining an elbow connection and flow-based speed adjustment.

02 / CONSTRUCTION

Construction & recognition

Often includes a check valve to distinguish inlet and exhaust throttling. Knob position does not directly indicate actuator speed.

03 / APPLICATIONS

Common applications

Adjusting cylinder reciprocating speed near its ports.

Browse this category

Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.

ENGINEERING GUIDE

Selection and design guide

An elbow speed controller combines a check valve and an adjustable needle in a fitting mounted at a pneumatic cylinder port. Meter-out control is the usual choice for double-acting cylinders. Select the metered direction, flow in both directions, port thread, tube OD and mounting orientation.

01Construction and operating principle

A one-way flow control valve has a check element and an adjustable needle in parallel. In the free-flow direction the check element opens. In the metered direction it closes and sends the air through the needle opening. Changing that opening changes the flow and the cylinder speed. An elbow model screws into the cylinder port, connects to the tube through a push-in fitting and has an adjusting screw with a locknut on top.

Elbow one-way flow controller. The cutaway shows the white push-in connection, upper needle locknut and lower male thread. The diagrams on the right show the check seal lifting to allow free flow and closing to force flow through the needle.
Elbow one-way flow controller. The cutaway shows the white push-in connection, upper needle locknut and lower male thread. The diagrams on the right show the check seal lifting to allow free flow and closing to force flow through the needle.SMC China, pneumatic fundamentals training material

In the handbook's meter-out example, air entering port 1 from the directional valve deflects the lip seal and flows through the annular clearance to port 2 at the cylinder. Cylinder exhaust reverses the flow, seats the lip seal and passes through the needle. The example uses a stainless steel adjusting screw, die-cast zinc swivel, aluminium-alloy threaded flange (nickel-plated brass for M5), nitrile rubber seal and acetal retaining ring.

02Types and size ranges

Variants by metered direction and application
TypeFlow meteredTypical application
Meter-out one-way flow controlAir leaving the cylinderGeneral speed control for double-acting cylinders.
Meter-in one-way flow controlAir entering the cylinderPowered stroke of a single-acting cylinder, clamping or low-friction cylinders, or limiting a sudden start.
Two-way flow controlFlow in both directionsSimple circuits with small or single-acting cylinders.
Exhaust-port flow control, often with a silencerExhaust at the directional valveAn adjustment point at the valve when the cylinder is hard to reach.
Precision one-way flow controlSmall flows with a graduated knobLow-speed adjustment around 5 mm/s in the handbook example.
Stroke-actuated flow controlFlow varies with positionPosition-dependent control or deceleration near the end of stroke.

Mechanical Design Handbook, Part 23, table 23-5-12, printed pages 23-268 to 23-271.

Mounting and adjustment styles
StyleFeatures
ElbowMounts on the cylinder port with the tube outlet to the side.
Universal or swivel elbowThe tube outlet can be oriented for routing.
In-lineTwo push-in connections allow installation within a tube run.
Panel mountFemale connections at both ends and provision for panel mounting.
Adjustment optionsA knurled knob for hand adjustment or a recessed slot for screwdriver adjustment.

Based on the six connection forms in figure i of Mechanical Design Handbook table 23-5-12, printed page 23-270.

Example size groups by flow capacity
Size groupPortMetered flow range
Miniature precision—About 0–1.7 L/min up to 0–40 L/min
SmallM5, G1/8About 0–18 L/min up to 0–40 L/min
StandardG1/8 to G3/4About 0–95 L/min up to 0–4320 L/min

Mechanical Design Handbook, table 23-5-12, printed page 23-268. Manufacturer size groups differ.

03Flow ratings and operating limits

Example one-way flow ratings at 0.6 MPa inlet and 0.5 MPa outlet
PortMetered flow (L/min)Free flow (L/min)
M50–9576–95
G1/80–340260–420
G1/40–610450–820
G3/80–1450970–1600
G1/20–21001550–2200
G3/40–43203220–4720

Meter-out examples in the continuation of Mechanical Design Handbook table 23-5-12, printed page 23-269. Its meter-in examples cover M5 through G1/4 and use the same values. Compare both flow directions as well as the thread.

Example flow and sound levels for directional-valve exhaust controls
PortWithout silencer (L/min)With silencer (L/min)Sound without / with silencer (dB(A))
G1/82–5200–100085 / 74
G1/42–9960–150080 / 80
G3/83–20000–170087 / 74
G1/23–36000–400090 / 76
G3/4—0–8000— / 80

Mechanical Design Handbook, table 23-5-12, printed page 23-268. The effect of the silencer on flow and sound varies with the model. Consult the selected product's data.

Additional selection data
ParameterWhat to check
Flow versus needle turnsPlot or read the flow curve from the closed position. A gradual rise near the closed end makes low flows easier to adjust.
Free flowThis limits the speed of the stroke in the unmetered direction.
Operating pressure and temperatureVerify the ratings of the selected speed controller in its catalogue.
Tube outside diameterMatch the push-in end to the tube and the threaded end to the cylinder port.
Adjustment lockUse the locknut. A cover or slotted adjustment can deter inadvertent changes.

Mechanical Design Handbook, table 23-5-12 continuation, printed page 23-269.

04Choosing meter-in or meter-out and calculating flow

Meter-out control at both cylinder ports. The controllers restrict exhaust. The pressure plot shows the supply side rising quickly while the exhaust side maintains back pressure during the stroke and falls at the end. This is the usual arrangement for stable adjustment of a double-acting cylinder.
Meter-out control at both cylinder ports. The controllers restrict exhaust. The pressure plot shows the supply side rising quickly while the exhaust side maintains back pressure during the stroke and falls at the end. This is the usual arrangement for stable adjustment of a double-acting cylinder.SMC China, pneumatic fundamentals training material
Meter-in control on the cylinder supply path. Exhaust pressure drops near zero at the start while supply pressure builds gradually. With little exhaust back pressure, compressibility makes speed less stable. Typical applications include the powered stroke of single-acting, clamping and low-friction cylinders.
Meter-in control on the cylinder supply path. Exhaust pressure drops near zero at the start while supply pressure builds gradually. With little exhaust back pressure, compressibility makes speed less stable. Typical applications include the powered stroke of single-acting, clamping and low-friction cylinders.SMC China, pneumatic fundamentals training material
Meter-out and meter-in compared
ConsiderationMeter-outMeter-in
Speed stabilityExhaust back pressure usually steadies the piston and reduces sensitivity to a changing load.With little exhaust back pressure, speed can vary and stick-slip may occur.
Restart after ventingThe initial stroke can surge if the exhaust chamber has already vented.Restricting the incoming air helps limit a sudden first stroke. Validate the restart in the actual circuit.
ApplicationsGeneral double-acting cylinder speed control. Back pressure can restrain the descending stroke of a vertical load during powered operation.Powered stroke of single-acting cylinders, clamping and low-friction cylinders, and circuits that need to limit initial speed.
Combined control—When combined in series, the meter-in control limits the initial surge and the meter-out control sets running speed. Place the meter-in controller nearer the cylinder as shown in the handbook circuit.

SMC pneumatic fundamentals, pages 54 and 55. Mechanical Design Handbook, table 23-5-12 continuation on printed page 23-270 and table 23-12-8 on page 23-512. Use independent load restraint where a vertical load must stay in place after pressure loss.

  1. Choose the metered directionStart with one meter-out controller at each port of a double-acting cylinder. Consider meter-in for the powered stroke of a single-acting or clamping cylinder. For restart surge, assess inlet restriction, a pressurized-center directional valve or a soft-start arrangement against the circuit's operating and restart requirements.
  2. Estimate the required metered flowUse piston area on the metered side, target speed and chamber pressure to calculate the air flow in L/min (ANR). Select a valve whose usable adjustment range covers this operating point without sitting near either end.
  3. Check the free-flow pathThe free-flow rating, directional valve and tubing affect the other stroke. See the directional solenoid valve reference for the speed estimate u0 = 1920·S/A.
  4. Match the thread and tubeMatch the cylinder port thread, for example M5, R1/8 or R1/4, and size the push-in end to suit the tube OD. Consider a swivel elbow or low-profile model where space is limited.
  5. Check the cylinder speed rangeThe handbook's typical range for a standard cylinder is 50–500 mm/s. Below 50 mm/s, check for stick-slip and consider a low-speed cylinder with precision flow control. Above 1000 mm/s, check the cylinder's allowable kinetic energy, cushioning and seal life.
Q = A · v × 60 × (p + 0.1013) / 0.1013 × 10⁻⁶
Q
Air flow through the restriction at reference atmospheric conditions, L/min (ANR)
A
Effective piston area on the metered side, mm². For meter-out extension use the rod-side annular area.
v
Cylinder speed, mm/s
p
Gauge pressure in the metered chamber, MPa. Using the supply pressure in place of a lower exhaust back pressure gives an upper estimate for sizing.

This estimate uses Boyle's law at constant temperature to convert chamber flow to atmosphere-referenced flow. See page 12 of SMC's pneumatic fundamentals and the cylinder air consumption calculator.

Estimate instantaneous air demand from bore, stroke and travel time.Size the cylinder and check the effective flow area needed for the target speed.
See the directional solenoid valve reference for effective flow area, baseline speed u0 = 1920·S/A and circuit flow estimates.Pneumatic Solenoid Valve →

05Installation and adjustment

  • Fit the controller close to the cylinder port. This keeps the volume between the piston and the restriction small. Mounting the restriction at the directional valve adds the entire tube volume, which can cause low-speed surging. An exhaust-port controller is an alternative when the adjustment must be accessible at the valve.
  • Confirm the direction from the circuit symbol or arrows. In meter-out operation, air from valve to cylinder flows freely and air from cylinder to valve is throttled. A visually similar meter-in model meters the opposite path.
  • Commission from low speed. Start with the needle closed as specified by the product manual and open gradually to reach the target speed. Tighten the locknut and use a cover where needed.
  • Adjust extension and retraction separately. Adjust the controller governing one stroke before changing the other.
  • Check the order of combined meter-in and meter-out controllers. In the handbook circuit (table 23-12-8), the meter-in controller is closer to the cylinder.
  • Check which stroke of a single-acting cylinder needs control. Meter-in controls the powered stroke. The spring and exhaust path determine the return speed.
  • Use the specified thread sealing and torque. Excessive torque can damage the threads in an aluminium end cover. The handbook gives five installation cycles as a general limit for the presealed R-thread examples it discusses.
See the tie-rod cylinder reference for load ratio, bore and cushioning checks.Tie Rod Cylinder →

06Troubleshooting and maintenance

Symptoms, causes and actions
SymptomLikely causesWhat to check
Stick-slipSpeed below about 50 mm/s, meter-in control, high load ratio, long tube between valve and cylinder, or poor cylinder lubrication.Try meter-out at the cylinder, check available force and consider a low-speed cylinder or precision controller. Hydraulic speed control is another option for very low speed.
First stroke surgesThe exhaust chamber has vented through an exhaust-center valve, shutdown or leakage during a long stop.Evaluate a pressurized center, inlet restriction, soft start or sequenced pressurization before the first stroke.
Needle turns have little effectWrong flow direction, controller too large, or the circuit is more restrictive elsewhere.Check direction and the effective area S of the solenoid valve and tubing. Use a smaller controller if the usable adjustment range requires it.
Slow free-flow strokeInsufficient free-flow capacity or a worn check seal.Check a larger model or replace the worn valve.
Speed driftsLoose locknut, vibration or temperature variation.Secure the adjustment and consider a recessed adjuster or a cover.
Port or tube leaksRepeated assembly or excess torque on the R thread, or an angled or scored tube end.Replace the damaged fitting. Cut the tube square and insert it fully.

Mechanical Design Handbook, Part 23. Table 23-4-6 continuation, printed page 23-89, table 23-5-12 on page 23-270, table 23-12-8 on page 23-512 and chapter 10 on page 23-470.

07Common design mistakes

  • Using meter-in by default on a double-acting cylinder. Meter-out usually gives more stable speed across load changes.
  • Selecting by thread alone. A G1/8 example with 0–340 L/min of metered flow may leave too little needle travel for fine adjustment on a small cylinder. Check the actual operating point.
  • Overlooking the first stroke after venting. With an exhaust-center valve and meter-out control, the unpressurized exhaust chamber cannot provide immediate back pressure. Verify the restart behavior.
  • Placing the controller 2 m away at the solenoid valve. The tube between the restriction and the cylinder adds compressible volume and can make low-speed travel and stopping less consistent.
  • Expecting uniform speed below 10 mm/s from a standard cylinder. The handbook notes a tendency toward stick-slip below 50 mm/s. Consider a low-speed cylinder, precision valve or hydraulic damping.
  • Using the speed controller as end-of-stroke cushioning. Adjust running speed with the flow controller and absorb end-of-stroke energy with appropriate cushioning or a shock absorber.
  • Reversing the order of controllers in the combined circuit. Place the meter-in controller closer to the cylinder in the illustrated arrangement.
Related devices for soft start, quicker exhaust on one stroke and exhaust noise reduction.Soft Start Exhaust Valve →Quick Exhaust Valve →Pneumatic Silencer →

08Standards and manufacturer references

Relevant standards cited in the handbook
ReferenceScope
GB/T 786.1—2009Graphic symbols and circuit diagrams for fluid power systems and components.
GB/T 14513—1993Measurement of flow characteristics of pneumatic components.
ISO 6358Flow characteristics of components using compressible fluids.
GB/T 14038—2008Pneumatic connections, ports and stud ends.
JB/T 6377—1992Types and dimensions of pneumatic port threads.

The editions listed come from Part 23, table 23-13-1, printed page 23-535. Confirm the applicable edition for the project.

  • SMC examples. Pages 53 and 56 of the pneumatic fundamentals material show elbow, in-line, push-in, threaded and exhaust-port versions. Use the model catalogue for dimensions and ratings.
  • When replacing a speed controller, compare the needle flow curve, free-flow rating and lock arrangement as well as its shape and thread.

—Sources

  • SMC China pneumatic fundamentals training materialPage 12 for Boyle's law, page 53 for the cutaway, pages 54 and 55 for meter-out and meter-in circuits and pressure plots, and page 56 for the fitting types.
  • Mechanical Design Handbook, Part 23, Chapter 5.4: Flow control valvesPrinted pages 23-268 to 23-271. Table 23-5-12 covers types, rated flow, sound levels, valve construction, connection forms, meter-in and meter-out circuits and precision valves.
  • Mechanical Design Handbook, Part 23, Chapter 4.1.2: Standard cylindersPrinted page 23-89. Continuation of table 23-4-6 for baseline speed, the 50–500 mm/s standard-cylinder range and stick-slip.
  • Mechanical Design Handbook, Part 23, Chapters 10, 12 and 13Printed pages 23-505 and 23-512 for speed-control and restart circuits (table 23-12-8), page 23-470 for R-thread assembly, and page 23-535 for standards.
  • SMC CG1 cylinder operation manual ↗Section 2-5 covers placement near the cylinder port, the usual meter-out arrangement, and gradual speed adjustment.

Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-26

ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN

Buying and using: calculators, sellers, uses

The notes below cover the “Fittings & accessories” category. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.

TOOLS / CALCULATE

Related selection calculators

Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.

07 / SELLERS

Who sells it

The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. Price comparison and ranking are not available yet.

Corresponding series by manufacturer

ManufacturerSeriesOfficial product page
SMCASOpen product page
FestoGRLAOpen product page
AirTACPSLOpen product page

Representative series and official product pages; a manufacturer may offer other suitable series. Product ranges, availability and applicability are governed by manufacturer information. This is not a ranking, recommendation or equivalence judgment.

08 / WHERE IT IS USED

Typical uses & where it sits in machines

Adjusting cylinder reciprocating speed near its ports.

Profile frameElectric linear moduleShock absorberGuided cylinderCylinder switchAir tubingRotary actuatorParallel gripperVacuum cupVacuum generatorVacuum switchValve islandFRL unitHere: Fittings & accessoriesSpeed controller
Pick-and-place unit (electric traverse, pneumatic lift and grip)Schematic, not to scaleArrow: Speed controller
气缸与阀之间的配管执行元件的速度调节阀排气口降噪工具与治具的快速接驳