ENGINEERING GUIDE
Selection and design guide
An elbow speed controller combines a check valve and an adjustable needle in a fitting mounted at a pneumatic cylinder port. Meter-out control is the usual choice for double-acting cylinders. Select the metered direction, flow in both directions, port thread, tube OD and mounting orientation.
01Construction and operating principle
A one-way flow control valve has a check element and an adjustable needle in parallel. In the free-flow direction the check element opens. In the metered direction it closes and sends the air through the needle opening. Changing that opening changes the flow and the cylinder speed. An elbow model screws into the cylinder port, connects to the tube through a push-in fitting and has an adjusting screw with a locknut on top.
Elbow one-way flow controller. The cutaway shows the white push-in connection, upper needle locknut and lower male thread. The diagrams on the right show the check seal lifting to allow free flow and closing to force flow through the needle.SMC China, pneumatic fundamentals training material
In the handbook's meter-out example, air entering port 1 from the directional valve deflects the lip seal and flows through the annular clearance to port 2 at the cylinder. Cylinder exhaust reverses the flow, seats the lip seal and passes through the needle. The example uses a stainless steel adjusting screw, die-cast zinc swivel, aluminium-alloy threaded flange (nickel-plated brass for M5), nitrile rubber seal and acetal retaining ring.
02Types and size ranges
Variants by metered direction and application
Type
Flow metered
Typical application
Meter-out one-way flow control
Air leaving the cylinder
General speed control for double-acting cylinders.
Meter-in one-way flow control
Air entering the cylinder
Powered stroke of a single-acting cylinder, clamping or low-friction cylinders, or limiting a sudden start.
Two-way flow control
Flow in both directions
Simple circuits with small or single-acting cylinders.
Exhaust-port flow control, often with a silencer
Exhaust at the directional valve
An adjustment point at the valve when the cylinder is hard to reach.
Precision one-way flow control
Small flows with a graduated knob
Low-speed adjustment around 5 mm/s in the handbook example.
Stroke-actuated flow control
Flow varies with position
Position-dependent control or deceleration near the end of stroke.
Mechanical Design Handbook, Part 23, table 23-5-12, printed pages 23-268 to 23-271.
Mounting and adjustment styles
Style
Features
Elbow
Mounts on the cylinder port with the tube outlet to the side.
Universal or swivel elbow
The tube outlet can be oriented for routing.
In-line
Two push-in connections allow installation within a tube run.
Panel mount
Female connections at both ends and provision for panel mounting.
Adjustment options
A knurled knob for hand adjustment or a recessed slot for screwdriver adjustment.
Based on the six connection forms in figure i of Mechanical Design Handbook table 23-5-12, printed page 23-270.
Example one-way flow ratings at 0.6 MPa inlet and 0.5 MPa outlet
Port
Metered flow (L/min)
Free flow (L/min)
M5
0–95
76–95
G1/8
0–340
260–420
G1/4
0–610
450–820
G3/8
0–1450
970–1600
G1/2
0–2100
1550–2200
G3/4
0–4320
3220–4720
Meter-out examples in the continuation of Mechanical Design Handbook table 23-5-12, printed page 23-269. Its meter-in examples cover M5 through G1/4 and use the same values. Compare both flow directions as well as the thread.
Example flow and sound levels for directional-valve exhaust controls
Port
Without silencer (L/min)
With silencer (L/min)
Sound without / with silencer (dB(A))
G1/8
2–520
0–1000
85 / 74
G1/4
2–996
0–1500
80 / 80
G3/8
3–2000
0–1700
87 / 74
G1/2
3–3600
0–4000
90 / 76
G3/4
—
0–8000
— / 80
Mechanical Design Handbook, table 23-5-12, printed page 23-268. The effect of the silencer on flow and sound varies with the model. Consult the selected product's data.
Additional selection data
Parameter
What to check
Flow versus needle turns
Plot or read the flow curve from the closed position. A gradual rise near the closed end makes low flows easier to adjust.
Free flow
This limits the speed of the stroke in the unmetered direction.
Operating pressure and temperature
Verify the ratings of the selected speed controller in its catalogue.
Tube outside diameter
Match the push-in end to the tube and the threaded end to the cylinder port.
Adjustment lock
Use the locknut. A cover or slotted adjustment can deter inadvertent changes.
04Choosing meter-in or meter-out and calculating flow
Meter-out control at both cylinder ports. The controllers restrict exhaust. The pressure plot shows the supply side rising quickly while the exhaust side maintains back pressure during the stroke and falls at the end. This is the usual arrangement for stable adjustment of a double-acting cylinder.SMC China, pneumatic fundamentals training materialMeter-in control on the cylinder supply path. Exhaust pressure drops near zero at the start while supply pressure builds gradually. With little exhaust back pressure, compressibility makes speed less stable. Typical applications include the powered stroke of single-acting, clamping and low-friction cylinders.SMC China, pneumatic fundamentals training material
Meter-out and meter-in compared
Consideration
Meter-out
Meter-in
Speed stability
Exhaust back pressure usually steadies the piston and reduces sensitivity to a changing load.
With little exhaust back pressure, speed can vary and stick-slip may occur.
Restart after venting
The initial stroke can surge if the exhaust chamber has already vented.
Restricting the incoming air helps limit a sudden first stroke. Validate the restart in the actual circuit.
Applications
General double-acting cylinder speed control. Back pressure can restrain the descending stroke of a vertical load during powered operation.
Powered stroke of single-acting cylinders, clamping and low-friction cylinders, and circuits that need to limit initial speed.
Combined control
—
When combined in series, the meter-in control limits the initial surge and the meter-out control sets running speed. Place the meter-in controller nearer the cylinder as shown in the handbook circuit.
SMC pneumatic fundamentals, pages 54 and 55. Mechanical Design Handbook, table 23-5-12 continuation on printed page 23-270 and table 23-12-8 on page 23-512. Use independent load restraint where a vertical load must stay in place after pressure loss.
Choose the metered directionStart with one meter-out controller at each port of a double-acting cylinder. Consider meter-in for the powered stroke of a single-acting or clamping cylinder. For restart surge, assess inlet restriction, a pressurized-center directional valve or a soft-start arrangement against the circuit's operating and restart requirements.
Estimate the required metered flowUse piston area on the metered side, target speed and chamber pressure to calculate the air flow in L/min (ANR). Select a valve whose usable adjustment range covers this operating point without sitting near either end.
Check the free-flow pathThe free-flow rating, directional valve and tubing affect the other stroke. See the directional solenoid valve reference for the speed estimate u0 = 1920·S/A.
Match the thread and tubeMatch the cylinder port thread, for example M5, R1/8 or R1/4, and size the push-in end to suit the tube OD. Consider a swivel elbow or low-profile model where space is limited.
Check the cylinder speed rangeThe handbook's typical range for a standard cylinder is 50–500 mm/s. Below 50 mm/s, check for stick-slip and consider a low-speed cylinder with precision flow control. Above 1000 mm/s, check the cylinder's allowable kinetic energy, cushioning and seal life.
Q = A · v × 60 × (p + 0.1013) / 0.1013 × 10⁻⁶
Q
Air flow through the restriction at reference atmospheric conditions, L/min (ANR)
A
Effective piston area on the metered side, mm². For meter-out extension use the rod-side annular area.
v
Cylinder speed, mm/s
p
Gauge pressure in the metered chamber, MPa. Using the supply pressure in place of a lower exhaust back pressure gives an upper estimate for sizing.
This estimate uses Boyle's law at constant temperature to convert chamber flow to atmosphere-referenced flow. See page 12 of SMC's pneumatic fundamentals and the cylinder air consumption calculator.
See the directional solenoid valve reference for effective flow area, baseline speed u0 = 1920·S/A and circuit flow estimates.Pneumatic Solenoid Valve →
05Installation and adjustment
Fit the controller close to the cylinder port. This keeps the volume between the piston and the restriction small. Mounting the restriction at the directional valve adds the entire tube volume, which can cause low-speed surging. An exhaust-port controller is an alternative when the adjustment must be accessible at the valve.
Confirm the direction from the circuit symbol or arrows. In meter-out operation, air from valve to cylinder flows freely and air from cylinder to valve is throttled. A visually similar meter-in model meters the opposite path.
Commission from low speed. Start with the needle closed as specified by the product manual and open gradually to reach the target speed. Tighten the locknut and use a cover where needed.
Adjust extension and retraction separately. Adjust the controller governing one stroke before changing the other.
Check the order of combined meter-in and meter-out controllers. In the handbook circuit (table 23-12-8), the meter-in controller is closer to the cylinder.
Check which stroke of a single-acting cylinder needs control. Meter-in controls the powered stroke. The spring and exhaust path determine the return speed.
Use the specified thread sealing and torque. Excessive torque can damage the threads in an aluminium end cover. The handbook gives five installation cycles as a general limit for the presealed R-thread examples it discusses.
See the tie-rod cylinder reference for load ratio, bore and cushioning checks.Tie Rod Cylinder →
06Troubleshooting and maintenance
Symptoms, causes and actions
Symptom
Likely causes
What to check
Stick-slip
Speed below about 50 mm/s, meter-in control, high load ratio, long tube between valve and cylinder, or poor cylinder lubrication.
Try meter-out at the cylinder, check available force and consider a low-speed cylinder or precision controller. Hydraulic speed control is another option for very low speed.
First stroke surges
The exhaust chamber has vented through an exhaust-center valve, shutdown or leakage during a long stop.
Evaluate a pressurized center, inlet restriction, soft start or sequenced pressurization before the first stroke.
Needle turns have little effect
Wrong flow direction, controller too large, or the circuit is more restrictive elsewhere.
Check direction and the effective area S of the solenoid valve and tubing. Use a smaller controller if the usable adjustment range requires it.
Slow free-flow stroke
Insufficient free-flow capacity or a worn check seal.
Check a larger model or replace the worn valve.
Speed drifts
Loose locknut, vibration or temperature variation.
Secure the adjustment and consider a recessed adjuster or a cover.
Port or tube leaks
Repeated assembly or excess torque on the R thread, or an angled or scored tube end.
Replace the damaged fitting. Cut the tube square and insert it fully.
Mechanical Design Handbook, Part 23. Table 23-4-6 continuation, printed page 23-89, table 23-5-12 on page 23-270, table 23-12-8 on page 23-512 and chapter 10 on page 23-470.
07Common design mistakes
Using meter-in by default on a double-acting cylinder. Meter-out usually gives more stable speed across load changes.
Selecting by thread alone. A G1/8 example with 0–340 L/min of metered flow may leave too little needle travel for fine adjustment on a small cylinder. Check the actual operating point.
Overlooking the first stroke after venting. With an exhaust-center valve and meter-out control, the unpressurized exhaust chamber cannot provide immediate back pressure. Verify the restart behavior.
Placing the controller 2 m away at the solenoid valve. The tube between the restriction and the cylinder adds compressible volume and can make low-speed travel and stopping less consistent.
Expecting uniform speed below 10 mm/s from a standard cylinder. The handbook notes a tendency toward stick-slip below 50 mm/s. Consider a low-speed cylinder, precision valve or hydraulic damping.
Using the speed controller as end-of-stroke cushioning. Adjust running speed with the flow controller and absorb end-of-stroke energy with appropriate cushioning or a shock absorber.
Reversing the order of controllers in the combined circuit. Place the meter-in controller closer to the cylinder in the illustrated arrangement.
Graphic symbols and circuit diagrams for fluid power systems and components.
GB/T 14513—1993
Measurement of flow characteristics of pneumatic components.
ISO 6358
Flow characteristics of components using compressible fluids.
GB/T 14038—2008
Pneumatic connections, ports and stud ends.
JB/T 6377—1992
Types and dimensions of pneumatic port threads.
The editions listed come from Part 23, table 23-13-1, printed page 23-535. Confirm the applicable edition for the project.
SMC examples. Pages 53 and 56 of the pneumatic fundamentals material show elbow, in-line, push-in, threaded and exhaust-port versions. Use the model catalogue for dimensions and ratings.
When replacing a speed controller, compare the needle flow curve, free-flow rating and lock arrangement as well as its shape and thread.
—Sources
SMC China pneumatic fundamentals training materialPage 12 for Boyle's law, page 53 for the cutaway, pages 54 and 55 for meter-out and meter-in circuits and pressure plots, and page 56 for the fitting types.
Mechanical Design Handbook, Part 23, Chapter 5.4: Flow control valvesPrinted pages 23-268 to 23-271. Table 23-5-12 covers types, rated flow, sound levels, valve construction, connection forms, meter-in and meter-out circuits and precision valves.
Mechanical Design Handbook, Part 23, Chapter 4.1.2: Standard cylindersPrinted page 23-89. Continuation of table 23-4-6 for baseline speed, the 50–500 mm/s standard-cylinder range and stick-slip.
Mechanical Design Handbook, Part 23, Chapters 10, 12 and 13Printed pages 23-505 and 23-512 for speed-control and restart circuits (table 23-12-8), page 23-470 for R-thread assembly, and page 23-535 for standards.
SMC CG1 cylinder operation manual ↗Section 2-5 covers placement near the cylinder port, the usual meter-out arrangement, and gradual speed adjustment.
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-26
ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN
Buying and using: calculators, sellers, uses
The notes below cover the “Fittings & accessories” category. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.
TOOLS / CALCULATE
Related selection calculators
Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.
The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. Price comparison and ranking are not available yet.
Representative series and official product pages; a manufacturer may offer other suitable series. Product ranges, availability and applicability are governed by manufacturer information. This is not a ranking, recommendation or equivalence judgment.
SMCPneumatic actuators, controls, vacuum and fluid-control components.