Check cylinder bore at the lowest working pressure
Screen bores against the required axial force and your selected load factor. On retraction, the piston rod reduces the effective area of a single-rod cylinder.
Worked example with a 300 N retraction load
Available retraction force = P × π(D² − d²) / 4 × η
D is the bore and d is the rod diameter in mm. Use pressure P in MPa. The result is in N after applying load factor η. For extension, use the full piston area πD²/4.
With a 50% load factor, the quick check first selects a 40 mm bore at 0.6 MPa (6 bar). At 0.5 MPa (5 bar) the CP96 40 mm bore with a 16 mm rod delivers about 528 N theoretically, or 264 N at 50%. Check the 50 mm bore for the lower pressure.
Check the actual cylinder and mounting
Verify the rod diameter, stroke, mounting, side load and cushioning for the selected series. For a vertical load, also verify holding after loss of pressure.