How to calculate compressed air consumption by device and by machine
Use average consumption to estimate total air demand. Check simultaneous flow for piping, valves and air preparation equipment. Convert catalogue and measured flows to the same reference conditions before adding them.
Worked example for a double-acting cylinder
q = [(A₁ + A₂)·L + V_tube] × [(P + 0.1013)/0.1013] × 10⁻⁶
Use the full piston area A₁ and rod-side annular area A₂ in mm², stroke L in mm and the combined volume V_tube of the two tubes from the valve in mm³. Enter gauge pressure P in MPa. The result q is the air consumption per full extend-and-retract cycle in L (ANR). Multiply by cycles per minute and the number of identical cylinders for average demand.
Use one cylinder with a 40 mm bore, 16 mm rod and 100 mm stroke at 0.5 MPa gauge. Set each tube to 6 mm ID and 1 m length. At 20 cycles per minute and 0.5 s to extend, the cylinder uses about 1.708 L (ANR) per cycle, or 34.16 L/min on average. It draws an estimated 89.51 L/min during extension.
Combine the cylinder with an intermittent vacuum ejector
Q_avg = Q_on × device count × seconds supplied per minute / 60
Add one Vacuum ejector and select Intermittent by cycle. Enter a hypothetical supply-side flow of 40 L/min (ANR), 3 seconds per event and 8 events per minute. The ejector averages 16 L/min. Together the two groups use 50.16 L/min on average and draw an estimated 129.51 L/min if the cylinder extends while the ejector is on.
For an ejector with air saving, count initial evacuation and later top-up time. Use the supply-side consumption entry in the catalogue. Check whether the nozzle, vacuum release pulse or ionizing bar can run at the same time when sizing the shared supply.
Compare catalogue flows on a common basis
Use L/min (ANR) or m³/h (ANR). The tool converts cubic meters to liters and hours to minutes. Convert any flow reported at other reference temperatures or pressures before entry.
For a branch or main line, check which operations can overlap and confirm pressure drop at that flow. Air dryer selection also depends on operating temperature, pressure and required pressure dew point.