A positive-displacement compressor that raises air pressure in steps by changing cylinder volume with a reciprocating piston, usually supplied as a package with receiver, cooler and controls.
02 / CONSTRUCTION
Construction & recognition
A crankshaft drives the piston through a connecting rod, and inlet and discharge valves are mostly self-acting, opening on pressure difference. Compression on one side only is single-acting; on both sides it is double-acting. Small units are often V-configured, large double-acting units L-configured with a vertical low-pressure and horizontal high-pressure cylinder, plus flywheel, intercooler and lubrication.
03 / APPLICATIONS
Common applications
Duties needing higher pressure and intermittent flow: workshop air, purging, test stands and small high-pressure supply.
Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
A crankshaft and a connecting rod drive a piston back and forth to compress air, and the machine is often supplied as a package with an air receiver. The construction is simple and the pressure range wide, so it suits small flows, intermittent use and higher pressures; besides delivery and pressure, selection must look at the duty cycle (how long it can run continuously), the load factor, and the noise and vibration.
01Construction and how it works
A motor turns the crankshaft and the connecting rod moves the piston back and forth in the cylinder. On the downward stroke the pressure in the cylinder falls below that on the inlet side, the inlet valve opens and air is drawn in. On the upward stroke the air is compressed and, once the pressure in the cylinder is above the discharge pipe, the discharge valve opens and the air leaves. Section 2.1.2 of the Atlas Copco Compressed Air Manual (the Manual below): most piston machines use self-acting valves, whose plates open and close on the pressure difference across them; small machines are mostly V arranged and large double-acting machines mostly L arranged (vertical low pressure cylinder, horizontal high pressure cylinder). Compression on one side of the piston only is single-acting, and compression on both sides is double-acting.
Section through a piston compressor (Manual figure 2:1, Piston compressor): a V arranged air-cooled piston machine; the cutaway shows the crankshaft, the connecting rod and the piston, the inlet and discharge valve plates in the cylinder head, and cooling fins on the cylinder and the head for air coolingSource: Atlas Copco, Compressed Air Manual, 9th edition
Table 23-2-1 of the Mechanical Design Handbook: a single stage piston machine compressing above 0.6 MPa runs hot and at low efficiency, so two stage compression with intercooling is common. For a final pressure of 1.0 MPa the first stage usually goes to 0.3 MPa. The discharge temperature is about 70 °C on 2.2~7.5 kW models and about 180 °C from 15 kW up. The discharge of a piston machine is intermittent, so an air receiver is needed to smooth the pulsation. An oil-free piston machine (Manual 2.1.3) uses PTFE or carbon piston rings, and large models have a crosshead and a ventilated distance piece that keep crankcase oil out of the compression chamber.
For delivery, pressure, air receiver and pipework calculations see the screw air compressor article; for small oil-free low noise duty a scroll compressor is also worth looking atScrew air compressor →Scroll air compressor →
02Types and designation systems
By lubrication and number of stages (Atlas Copco L series examples)
Series
Lubrication
Stages
Maximum pressure bar
Notes
LE
Oil-lubricated
Single stage
10
General industrial machine
LT
Oil-lubricated
Two stage (three stage for the 40 bar model)
15, 20, 30, 40
Higher pressure
LFx / LFxD
Oil-free
Single stage, single cylinder
10
LFxD has an integrated dryer
LF
Oil-free
Single stage, two cylinder
10
Industrial oil-free machine
LZ
Oil-free
Single stage
10
With acoustic enclosure and touch screen controller
LB 40 / LB 300
Oil-lubricated
Single stage / two to three stage
40 / 300
Air and nitrogen booster, the inlet needs compressed air already
From the Atlas Copco Industrial piston compressors 0.7-60 hp / 0.5-44.7 kW catalogue (2023).
What the duty cycle means
Marking
Meaning
Example
S1
Continuous duty, can run 100% of the time
Atlas Copco LE series is rated 100% duty
S3-75
Intermittent periodic duty, 10 min cycle, 75% running
At most 7.5 min of running in every 10 min
S3-50, S3-25 and others
As above, with a lower running proportion
Maker notes: some models go down to 25%
Compiled from the Atlas Copco What is piston compressor duty cycle?: the duty cycle of a small piston machine is generally based on a 10 min period and is read from the S marking on the motor nameplate; running beyond the duty cycle overheats the piston and seizes the cylinder. The L series catalogue states 100% duty for most models, with an oil-lubricated life of 20000 h and an oil-free life of 16000 h.
03Boundary dimensions and mounting space
Most small piston machines are tank-mounted units with the compressor head and the motor on the air receiver, and the outline is set by the receiver volume. The table below uses the Atlas Copco LE/LT as the reference; the catalogue gives only the overall dimensions, and the inlet and outlet positions and the foot hole spacing have to be read from the maker's outline drawing (follow the catalogue). Receiver volumes at a given level are often 90, 250 L and similar, but horizontal or vertical mounting and the direction of the head differ, so a change of make has to be rechecked.
Atlas Copco LE / LT tank-mounted piston compressors (series examples)
Model
Maximum pressure bar
Delivery FAD l/s
Motor kW
Noise dB(A) standard/quiet
Air receiver L
Weight kg
Overall L×W×H mm
LE 2-10/90
10
3.40
1.5
80 / 65
90
85
1118 × 510 × 1017
LE 3-10/90
10
4.40
2.2
81 / 66
90
89
1118 × 510 × 1017
LE 5-10/250
10
8.40
4.0
81 / 66
250
150
1852 × 510 × 1082
LE 7-10/250
10
11.70
5.5
82 / 70
250
191
1852 × 592 × 1162
LE 10-10/250
10
15.70
7.5
83 / 70
250
203
1852 × 592 × 1162
LE 15-10/250
10
18.60
11.0
86 / —
250
330
1852 × 790 × 1200
LE 20-10/250
10
23.90
15.0
86 / —
250
360
1852 × 790 × 1200
LT 5-20/250
20
5.00
4.0
81 / 66
250
170
1852 × 533 × 1082
LT 10-20/250
20
9.10
7.5
83 / 70
250
223
1852 × 606 × 1162
LT 20-20/250
20
18.00
15.0
86 / 73
250
361
1852 × 830 × 1980
LT 10-30 (head on base version)
30
8.50
7.5
83 / —
—
102
932 × 606 × 600
From the LE/LT page (catalogue page 18) of the Atlas Copco General catalog for compressed air, gas and vacuum solutions. The two noise columns follow the catalogue table, the second column being the quiet version, and — means the catalogue does not list a value. The 2023 L series catalogue gives slightly different LE deliveries (for example 23.9 l/s for LE 15-10), so select from the latest catalogue.
Connections and installation requirements
Item
Requirement and source
Power supply
The oil-free L series has 230/400/460 V supply options and needs a single point connection; the motor is IP55 with class F insulation (LE/LT page of the general catalogue)
Starting
The LB booster uses star-delta reduced voltage starting (2023 catalogue); small models start direct, follow the catalogue
Air outlet
The receiver outlet valve connects to the pipework; the receiver must have a safety valve, a pressure gauge and a drain valve (Mechanical Design Handbook table 23-2-5)
Drain
Drain from the bottom of the receiver, with a timer drain as an option; condensate containing oil has to be treated
Inlet
Manual 3.5.4: the inlet pipe of a piston machine needs particular care, because acoustic standing waves in the pipe driven by the pulsation damage the pipe and the compressor and produce low frequency noise
Foundation
Manual 3.5.3: a level floor is usually enough, and a large piston machine or a centrifugal compressor may have to be anchored to a concrete foundation on rock or firm soil
Service space
Not given in the catalogue, see the maker's instruction book; leave 1200 mm in front of the electrical control cabinet (general requirement of Manual 3.5)
Material follows the current version on the maker website.
04Key parameters
Parameters that matter especially on a piston machine
Parameter
Meaning
How to use it in selection
Delivery FAD
Measured to ISO 1217 annex C
Note that catalogues often list the theoretical displacement separately from FAD, and select on FAD
Duty cycle
S1 continuous / S3-xx intermittent
The average demand as a share of the delivery must not exceed the permitted running proportion
Load factor
Actual running (loaded) time as a share of total time
Where it approaches or exceeds the duty cycle, go one size up, or add a receiver so that the machine can rest
Stages and maximum pressure
Single stage to 10 bar, two stage 15~30 bar, three stage 40 bar
The higher the pressure, the more stages
Noise
Average sound pressure level at 1 m (ISO 2151 / Pneurop Cagi PN8NTC2)
LE open types are 78~90 dB(A), so a quiet type is needed beside a workstation
Lubrication
Oil-lubricated / oil-free (Class 0)
Oil-free models have a shorter catalogue life (16000 h against 20000 h)
Compiled from the Atlas Copco L series catalogue (2023) and What is piston compressor duty cycle?.
Order of magnitude of the noise (series examples, dB(A))
Series
Power range kW
Noise
LFx oil-free small
0.55~1.5
64~67
LF oil-free
1.5~7.5
82~86
LZ oil-free with enclosure
5.5~15
72~77
LE oil-lubricated, open / enclosed
1.5~15
78~90 / 63~78
LT oil-lubricated, open
1.5~45
78~94
From the technical data tables of the Atlas Copco L series catalogue (2023); the 50/60 Hz values differ slightly.
05Selection and calculation
Work out the average and the maximum air demandSee the screw air compressor article for the method. A piston machine is selected on average demand plus an air receiver, and table 23-2-1 of the Mechanical Design Handbook gives the supply as the average consumption multiplied by a correction factor of 1.3~1.5.
Check the duty cycleDivide the average demand by the FAD to get the running proportion needed and compare it with the duty cycle. Atlas Copco advises going one size larger where the air supply is continuous, so that the machine has pauses and the receiver supplies the air during them.
Size the air receiverA small start/stop machine (below about 5~10 kW) needs a large receiver or a wide pressure band to keep the number of starts down (Manual 2.5.2.5); the receiver volume calculation is in the screw air compressor article.
Fix the pressure and the number of stagesSingle stage up to 10 bar, two or three stages above; where only one point needs high pressure, use a booster (LB) rather than raising the pressure of the whole system.
Check the noise and the locationBeside a work area choose the quiet type, or group the machines in a compressor room.
Control methods of a piston machine
Method
What is done
Features
Start/stop
Stop at the upper pressure and start at the lower
Most common on small machines; the L series LE/LT uses start/stop rather than load/unload
Inlet valve unloading
Hold the inlet valve open so that the air moves in and out of the cylinder without being compressed
The loss is usually below 10% of the full load shaft power; a double-acting machine can unload cylinder by cylinder for step control
Starting unload
A dump valve releases the cylinder pressure at start
Cuts the starting torque and lengthens motor life (LF/LZ industrial unload valve)
From Manual 2.5.2.5 and 2.5.2.8 and the Atlas Copco L series catalogue (2023).
Stand the machine on a firm level floor; a tank-mounted unit is fixed by the receiver feet, with antivibration pads as the instruction book gives (follow the catalogue).
Keep the inlet pipe short and large enough in bore, and avoid resonance with the pulsation frequency; fit a silencer on the inlet side where necessary.
Drain the air receiver every day; the safety valve is set about 10% above the normal working pressure (Mechanical Design Handbook table 23-2-5).
On an oil-lubricated machine check the oil level and change the oil regularly; an oil-free machine takes no oil, but its piston rings and valve plates are replaced by hours (follow the instruction book).
Ventilation: the head is cooled by a fan, so do not box it in, and do not let the hot air return to the inlet.
07Failure modes and maintenance
Common problems, causes and actions
Symptom
Main cause
Action
High discharge temperature, seized cylinder
Running continuously beyond the duty cycle, poor ventilation
Check the load factor and choose a continuous duty model or one size up
Frequent starting, motor overheating
Air receiver too small or pressure band too narrow
Enlarge the air receiver or widen the pressure band
Much oil in the discharge (oil-lubricated machine)
Worn piston rings, oil level too high
Change the rings and set the oil level as the instruction book gives
Delivery falls
Inlet filter blocked, valve plates damaged
Clean the element and change the valve plates
Inlet pipe cracked by vibration, low frequency noise
The inlet pipe resonates with the pulsation frequency
Change the pipe length and its supports, and add a silencer
Water in the pipework
No aftercooler or dryer fitted
Add an aftercooler and a dryer, and drain on schedule
Compiled from Manual 2.1 and 3.5.4, the Atlas Copco duty cycle notes and tables 23-2-1 and 23-2-5 of the Mechanical Design Handbook.
08Common design mistakes
Choosing a small machine for the peak demand and running it flat out. A machine rated S3 overheats in long continuous running, so check against the average demand and the duty cycle.
No air receiver, or one that is too small. A piston machine discharges intermittently, and without a receiver the pressure pulsation is large and it starts and stops often.
Putting a piston machine beside a workstation. An open type is 80~90 dB(A), so either choose the quiet type or put the machine in a compressor room.
Running the inlet pipe anywhere. Resonance driven by the pulsation cracks the inlet pipe and also produces annoying low frequency noise.
Raising the pressure of the whole plant for one high pressure point. Use a booster to raise the pressure locally.
09Standards and manufacturer ranges
Related standards
Standard
Content
Source
ISO 1217 annex C
Delivery measurement
Atlas Copco L series catalogue
ISO 2151 / Pneurop Cagi PN8NTC2
Compressor noise measurement
Atlas Copco L series catalogue
ISO 8573-1:2010
Compressed air quality classes, oil-free models certified Class 0
Atlas Copco L series catalogue
S1, S3 duty cycles
Motor rating and duty cycle (S marking)
Atlas Copco duty cycle notes
The current edition of each applies.
Atlas Copco: oil-lubricated LE and LT, oil-free LF, LFx, LFxD and LZ, boosters LB 40 and LB 300; the Automan portable small machine (general catalogue).
Mechanical Design Handbook, part 23 Pneumatic transmission, chapter 2 Compressed air stations, pipe networks and productsTable 23-2-1 classification, working principle and selection calculation of air compressors (printed pages 23-31~23-33, piston compressor principle, two stage compression, discharge temperature, characteristic comparison); table 23-2-5 air receivers (printed page 23-36)
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-18
Uses the change in cylinder volume caused by a piston to produce compressed air.
Operating principle
A crankshaft drives the piston back and forth. Cylinder volume increases during intake. The inlet valve closes during compression, and the outlet valve opens when pressure is high enough to deliver air downstream.
Process sequence
Check lubrication and cooling
Start the drive
Draw air into the cylinder
Compress and discharge the air
Cool and regulate the output, and drain condensate
Key inputs
Required airflow and pressure
Inlet air conditions
Duty cycle
Air quality target
Common mistakes
The piston and cylinder compress the air, and the receiver stores it. A screw compressor uses a different compression mechanism.
Scope and limitations
Single-stage and multistage units, and lubricated and oil-free units, differ in construction and air treatment needs.
Size the receiver and dryer for the compressed-air system.
Functional modules
Drive and crankshaft
Convert drive power to reciprocating piston motion.
Piston and cylinder
Vary cylinder volume for intake and compression.
Inlet and outlet valves
Open and close in response to pressure differences to control flow into and out of the cylinder.
Cooling and lubrication
Remove heat from compression and motion. Lubricate moving parts as required by the unit design.
Unit controls
Coordinate starts, stops and regulation, and monitor operating status.