Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
A stud bolt has a thread at each end: the tap end (metal end) is screwed into the body and normally left there, and the other end takes a nut that clamps the parts. In the Fabory catalogue the tap end length bm has three grades by body material: DIN 938 about 1d, mainly for steel; DIN 939 about 1.25d, mainly for cast iron; DIN 835 about 2d, mainly for aluminium alloy. On M10 the bm values are 10, 12 and 20 mm, and the tap end thread is made to Sk6 as a transition fit to DIN 13-51, so the stud does not come out when the nut is undone.
01Construction and how it works
A stud bolt is made of a tap end, a middle section and a nut end. The tap end, length bm (b1 on the Bossard drawing), is screwed into the tapped hole in the body; the nut end thread, length b, passes through the clamped parts and is tightened with a nut. The nominal length L does not include the tap end: in the Fabory example an M10×70 DIN 939 stud has bm = 12 mm, so the overall length is 70 + 12 = 82 mm.
Dimension designations of a stud bolt. Left: the tap end, length b1 (that is bm); middle: the thread run-out and the plain shank, with x¹ and x² the incomplete thread at each end; right: the nut end, thread length b; L is the nominal length, measured from the end of the tap end to the end face of the nut end; d1 is the thread sizeSource: Bossard, Stud bolts, tap end with interference fit, length ~1.25 d, BN 436 product page dimension drawing
Why not simply screw a bolt into the body: the body is often cast iron or aluminium alloy, a material whose internal thread wears quickly, and it is a large and costly part. With a stud only the nut is dismantled in everyday service, and the internal thread is turned once, when the stud is fitted, so repeated assembly does not wear it out. The stud also projects from the body and can guide a cover or a flange into position, with the part dropped over the studs.
The tap end should stay put once it is screwed in. The Fabory and Bossard catalogues state that the tap end thread of the standard DIN 938, 939 and 835 studs has a tolerance of Sk6 to DIN 13-51, a transition fit that stops the tap end loosening when the nut is undone; the matching internal thread is 6H. Where this fit is not wanted, "Fo" is added to the order designation and both ends are made to 6g; Fabory notes that this is supplied as a special, while Bossard stocks it (BN 1390 and BN 1391, DIN 939 Fo).
Tap end lengths and uses are from the Fabory DIN 938, DIN 939 and DIN 835 product pages; the size ranges are from the summary pages of the DIN website. The DIN site lists the 2025-08 edition of these three standards, so ordering and drawing follow the edition in force.
Chinese standard equivalents
Standard
Tap end
GB/T 897
bm = 1d
GB/T 898
bm = 1.25d
GB/T 899
bm = 1.5d
GB/T 900
bm = 2d
Listed by standard name; the Chinese standards have one more grade, 1.5d. The rounded bm values for each size are not necessarily the same as in DIN, so drawing to GB follows the text of the standard.
By tap end tolerance (Bossard DIN 939 range as the example)
Bossard number
Standard
Tap end
Fit
Material and finish
BN 436
DIN 939
b1 ≈ 1.25d
Interference (transition) fit, 6H / Sk6
Steel 8.8, black oxide or plain
BN 1390
DIN 939 Fo
b1 ≈ 1.25d
No interference, ordinary fit 6H / 6g
Steel, black oxide or plain
BN 1391
DIN 939 Fo
b1 ≈ 1.25d
No interference, ordinary fit 6H / 6g
Steel 8.8, zinc plated blue passivated
From the Bossard BN 436 and BN 1391 product pages (BN 1390 is a related product listed on the BN 436 page). The Fo tap end has no interference, so the stud may turn out with the nut; add a locking adhesive or a note on the assembly drawing.
Property classes: Fabory lists DIN 939 in 5.8 (zinc plated), 8.8 and 10.9 (plain), with stainless A2 and A4 versions as well. The class means the same as on a bolt and so does the proof load; the table below is taken from the DIN EN ISO 898-1 table in the Würth handbook.
03Key parameters
Tap end length bm and nut end thread b (mm)
Size
Pitch P
DIN 938 bm
DIN 939 bm
DIN 835 bm
Nut end b (L ≤ 125)
b (125 < L ≤ 200)
Run-out x
M6
1
—
7.5
—
18
24
2.5
M8
1.25
8
10
16
22
28
3.2
M10
1.5
10
12
20
26
32
3.8
M12
1.75
12
15
24
30
36
4.3
M16
2
16
20
—
38
44
5
Taken item by item from the Fabory product pages (class 8.8 plain: DIN 938 M8×30, M10×30, M12×40, M16×50; DIN 939 M6×30, M8×30, M10×40, M12×40, M16×50; DIN 835 M8×30, M10×30, M12×40). "—" marks a combination not found for this article. For a short stud the nut end thread is b = L − (x + 3), and the length up to which this applies differs by size, see the catalogue. For DIN 835 at L ≥ 200 the b of M10 is 45 and of M12 is 49.
Proof load Fp = As × Sp by class (N)
Size
Stress area As mm²
5.8
8.8
10.9
M6
20.1
7640
11600
16700
M8
36.6
13900
21200
30400
M10
58
22000
33700
48100
M12
84.3
32000
48900
70000
M16
157
59700
91000
130000
From table 3, Extract from DIN EN ISO 898-1, Test forces for ISO metric standard thread, of chapter 1 of the Würth DIN catalogue technical section. Proof stress Sp: 380 MPa for 5.8, 580 MPa for 8.8 (d ≤ 16) and 830 MPa for 10.9 (table 2 of the same chapter).
The example uses Fabory DIN 938 / 939 / 835 studs and reference values for MISUMI hex nuts and through holes. A stud takes space in three parts: the tapped hole in the body, whose depth is set by bm, the through hole in the clamped parts, and the projection above the body face, where the nut and the wrench sit.
Section dimensions after choosing bm by body material (mm)
Size
Steel: bm (DIN 938)
Cast iron: bm (DIN 939)
Aluminium alloy: bm (DIN 835)
Through hole d′
Nut across-flats s
Type 1 nut height m max
M8
8
10
16
9
13
6.8
M10
10
12
20
11
16
8.4
M12
12
15
24
14
18
10.8
M16
16
20
—
18
24
14.8
bm from the Fabory product pages; the through hole d′ from the reference table in MISUMI, Hexagon Socket Head Cap Screws; the nut s and m from MISUMI, Hexagon Nuts (an extract of JIS B 1181, type 1, product grade A). MISUMI notes that some M10 and M12 nuts in circulation still follow the old JIS across-flats.
Tapped hole in the body: the effective thread length is at least bm, and the drilling adds the tap run-out and the drill point; the tap end is a transition fit and must be stopped by the thread run-out, so a hole that is too shallow lets the stud bottom out, the tightening torque is false and the stud is not seated. Use the tapping calculator on this site for the tap drill and the drill depth.
Projection L: L ≥ the thickness of the clamped parts + the washer thickness + the nut height m + the allowance beyond the nut, worked out as for a hex bolt.
Wrench room above the body face: with a socket the socket comes down over the top of the stud, so leave axial space of the projection plus the socket length above the stud; a Stahlwille 1/2" socket for size 13 mm is 38 mm long with an 18.3 mm working end diameter, a 10 mm socket is 14.5 mm across, and both have a 22 mm square drive end.
Fitting the stud needs a tool too: the usual method is two nuts locked against each other with the outer one turned, or a dedicated stud driver. Leave wrench room beside the stud for this, not only for the nut.
Blind hole direction: stud holes in castings and aluminium parts are mostly blind, and chips and coolant at the bottom push the stud back; volume assembly needs a way to blow the hole clear.
Read the body material and set bmDIN 938 (≈1d) for steel parts, DIN 939 (≈1.25d) for cast iron and DIN 835 (≈2d) for aluminium alloy. Where the body is aluminium and the preload is high, a wire thread insert in the aluminium with a short stud is another route.
Set the size and class from the loadTension, fatigue and friction grip of a transverse load are worked out as for a bolt, see the socket head cap screw article; the strength of a stud is checked at the nut end.
Set the nut end length LAdd the thickness of the clamped parts, the washer, the nut height and the projection, then take a length from the catalogue series.
Set the tap end fitWhere the stud must stay put when the nut is undone, use the standard type (Sk6); where the stud will later be removed and replaced, or the internal thread tolerance is uncertain, use the Fo type with a locking adhesive.
Match the nut and set the torqueThe nut class is at least the first digit of the stud class; the torque follows the bearing face at the nut end and the state of lubrication.
Reference tightening torque and preload at the nut end (μG = μK = 0.12)
Size
8.8 preload kN
8.8 torque N·m
10.9 preload kN
10.9 torque N·m
M6
10.2
10.1
14.9
14.9
M8
18.6
24.6
27.3
36.1
M10
29.6
48
43.4
71
M12
43.0
84
63.2
123
M16
80.9
206
118.8
302
From table 5 of chapter 6 of the Würth DIN catalogue technical section (to VDI 2230, 90% utilisation of the yield strength, standard hex head and a medium clearance hole). A standard hex nut goes on the stud, so the bearing face is close to what the table assumes; where the friction differs (zinc plated dry, oiled) change column, as in the Würth example of zinc plated clear passivated without lubricant at μ = 0.14.
Another way of raising the internal thread strength in an aluminium part: a wire thread insertWire thread insert →
06Installation and use
Identify the ends first: the thread lengths differ and the short end (bm) goes into the body. On an M10 DIN 939 the bm is 12 and the nut end b is 26, which is easy to tell apart; on DIN 835 the bm and b are close (20 and 26 on M10), so fitting the wrong end is a common accident, and the tap end should be marked on the drawing.
Seat the stud: with two nuts or a stud driver, turn the stud in until the thread run-out touches the hole mouth; measure the projection, and keep all studs on one part at the same height.
Clean the hole: chips in a blind hole stop the stud early, so where the projections differ, check the hole first.
Dismantle at the nut only: routine maintenance undoes the nut, and the stud is not turned out again and again like a bolt; a stud that comes out with the nut means the tap end fit is insufficient or an Fo type was used.
Refitting a stud: the interference of an Sk6 tap end is partly lost once it is removed, so fit a new stud or add a locking adhesive.
Fo type (6g) tap end, oversize internal thread in the body, or a stud removed and refitted many times
Change to the standard Sk6 type or add a locking adhesive; repair the internal thread
Projections differ from stud to stud
Hole too shallow, chips at the bottom, or the wrong end fitted
Check the hole depth against bm; clean the hole; mark the tap end on the drawing
Internal thread pulls out of an aluminium body
A 1d or 1.25d stud screwed into an aluminium part
Use DIN 835 (≈2d) for aluminium, or a wire thread insert
Hole mouth cracks on a cast iron body
Excessive interference at the tap end, or the stud turned in at an angle
Line it up before turning; chamfer the hole mouth
Fatigue fracture at the nut end
Preload too low, so the alternating load falls entirely on the stud
Tighten to the torque table; check fatigue where the alternating load is high
Stud bends
The clamped parts are located by the stud and carry a transverse load
Give the transverse load to a pin or a spigot, and let the stud clamp only
Compiled from the Fabory and Bossard catalogue notes (the Sk6 transition fit, the Fo type, the grades by counterpart material).
08Common design mistakes
Using DIN 938 or DIN 939 in an aluminium part. Fabory states it plainly: 1d is mainly for steel, 1.25d mainly for cast iron, and aluminium alloy takes 2d.
Ordering by overall length instead of nominal length. An M10×70 DIN 939 stud is 82 mm overall, and the nominal length covers the nut end only.
Drawing the hole depth down to bm only. With no allowance for the tap run-out and the drill point the stud does not seat, and both the projection and the torque come out wrong.
Leaving the tap end fit unstated. "DIN 939 M10×40" alone means the Sk6 transition fit; a plain fit must be written as "Fo", or the body is machined to 6H and the assembly feels different from what was expected.
Using a stud as a locating pin. There is clearance between the stud and the through hole, so a transverse load bends and wears it; location belongs to a pin or a spigot.
Leaving no room on the body for fitting the stud. Only the socket for the nut was considered, and the two nuts and the wrench cannot be turned when the stud goes in.
09Standards and manufacturer ranges
Related standards
Standard
Subject
DIN 938
Stud bolts, tap end ≈ 1d
DIN 939
Stud bolts, tap end ≈ 1.25d
DIN 835
Stud bolts, tap end ≈ 2d
DIN 13-51
Metric threads, transition fit (Sk6 tap end tolerance)
GB/T 897~900
Stud bolts bm = 1d, 1.25d, 1.5d, 2d
DIN EN ISO 898-1
Mechanical properties of carbon and alloy steel fasteners: bolts, screws and studs
Current editions apply; the DIN website lists the 2025-08 edition of DIN 938, 939 and 835.
Fabory (Würth Group): DIN 938 (8.8), DIN 939 (5.8, 8.8, 10.9, stainless) and DIN 835 (8.8, stainless), with bm, b and x on the product pages.
Bossard: BN 436 (DIN 939, Sk6 transition fit), BN 1390 / BN 1391 (DIN 939 Fo, 6g).
Würth: DIN 938 and DIN 939 studs in steel 8.8 zinc plated and in A2 stainless.
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-24
ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN
Buying and using: calculators, sellers, uses
The notes below cover the “Screws & bolts” category. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.
TOOLS / CALCULATE
Related selection calculators
Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.
The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. Price comparison and ranking are not available yet.
MISUMIFactory automation and tooling components with selection and CAD resources.