A helical thread insert wound from stainless steel wire of diamond section. It is installed in a hole tapped with a special tap to strengthen or repair an internal thread.
02 / CONSTRUCTION
Construction & recognition
Once installed, the outer turn fits the thread of the parent material and the inner turn forms a standard internal thread. Types are free-running and locking, the latter with a polygonal locking coil. The installation end has a tang, which is broken off after setting.
03 / APPLICATIONS
Common applications
Threads that are taken apart often in low-strength materials such as aluminum alloy, magnesium alloy, cast iron and plastic, and the repair of damaged threads.
Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
An elastic helical insert wound from stainless steel wire of diamond section, screwed into a hole cut with a special tap to give a wear-resistant, high-strength standard internal thread in aluminium, magnesium, castings and plastics, and also used to repair a damaged thread. Selection sets the nominal length (1d to 3d) by the parent material strength and the screw property class, then the tap drill and the special tap follow the maker table; once installed the insert sits 0.25 to 0.5 pitch below the hole mouth, and in a through hole the tang must be broken off.
01Construction and how it works
A wire thread insert (HELICOIL is the Böllhoff brand name) is a wire of diamond section wound into an elastic helix: the outer flank fits the installing thread in the parent material and the inner flank is the standard internal thread. Free, its outside diameter is a set amount larger than the installing thread; screwed in, it is compressed and springs radially against the hole, so no adhesive or locking element is needed. The load passes from the screw flank to the insert and from the insert flank to the parent material, and the loaded thread in the parent is larger in diameter than a plain tapped hole, so the shear area grows; that is why a high-strength screw can be used in a low-strength material.
Left: a magnified photograph of the diamond section wire. Top right: the shape of the insert, the end view (notch, the breaking groove, and tang, the installation tang) and the wire cross section with 60° flanks on both sides. Bottom right: Rm minimum tensile strength 1400 N/mm²; HV Vickers hardness not below 425 HV0.2; Rz surface roughness about 2.5 μm; μG thread friction reduced, so the preload rises at the same tightening torque; τt torsional stress in the screw shank reducedSource: Böllhoff, HELICOIL Plus Thread technology for high-strength fastenings catalogue
The benefits listed by Böllhoff: the rolled wire surface is smooth, with a roughness about 90% lower than a cut thread, so the thread wears well and friction is low and stable (the catalogue example: a class 10.9 carbon steel screw in a cut thread gives μG between 0.12 and 0.18, and with an insert between 0.11 and 0.13), which makes the preload more accurate when tightening by torque; the spring of the insert absorbs pitch and flank angle errors, so the turns share load more evenly and the fatigue strength under dynamic load rises; and the stainless material resists seizure.
02Types and designation systems
Main HELICOIL types
Type
Character
Use
Free Running
Every turn has the standard flank form, thread accuracy 6H (4H on special request), and the insert can be turned in from either end
General thread strengthening and repair
Screwlock
One or more polygonal turns in the middle grip the screw flank and produce a prevailing torque, close to the ISO 2320 requirement
Locking in vibrating joints; only with class 8.8 screws and above
Tangfree
No installation tang, so nothing to break off or extract; needs a special installation tool
Automated assembly, aerospace
Plus and Classic
The Plus first turn is treated so the insert screws in like a screw and can be set with an installation mandrel close to the tap of the same size; Classic is the traditional type
Plus cuts assembly time by up to about 20%
From pages 5~7 of the Böllhoff catalogue HELICOIL Plus Thread technology for high-strength fastenings. Thread types cover metric coarse and fine (DIN ISO 13), pipe thread G (DIN EN ISO 228-1), UNC and UNF (NASM 21209), and BSW, BSF and BA. Metric coarse free running runs from M2~M42 with nominal lengths 0.5d~3d; the locking type from M2~M39 with 0.75d~3d (3d from M3 upward).
Insert materials (examples from the HELICOIL Plus range)
Material
Temperature range
Minimum tensile strength N/mm²
Use
Stainless A2 (1.4301)
−196 °C; 425 °C short term, 315 °C long term
1400
Standard item, for screws of all property classes and all parent materials
Magnesium alloy parts, to prevent contact corrosion
From the material table on page 12 of the Böllhoff catalogue HELICOIL Plus Thread technology for high-strength fastenings (the data apply to inserts that are not dyed). Magnesium parts used outdoors need extra corrosion protection.
The interface of a wire thread insert is the installing thread in the parent material: it is one size larger than the nominal screw diameter, so the tap drill, the countersink at the hole mouth, the hole depth and the wall around it are all drawn for the insert rather than for the screw. The Böllhoff HELICOIL Plus metric coarse range is used below; other brands have similar but not identical tap drill and installing thread sizes, and need their own tap and gauges.
HELICOIL Plus installing thread and tap drill (Böllhoff metric coarse example, mm)
Thread
Drill B
Installing thread minor dia. D1HC
Installing thread major dia. DHC min
Free outside dia. d1
Hole mouth countersink dia.
M3
3.20
3.11~3.22
3.65
3.80~4.00
DHC + 0.1
M4
4.20
4.15~4.29
4.91
5.05~5.25
DHC + 0.1
M5
5.20
5.17~5.33
6.04
6.35~6.60
DHC + 0.1
M6
6.30
6.22~6.41
7.30
7.60~7.85
DHC + 0.1
M8
8.40
8.27~8.48
9.62
9.85~10.10
DHC + 0.1
M10
10.50
10.32~10.56
11.95
12.10~12.50
DHC + 0.1
M12
12.50
12.38~12.64
14.27
14.40~14.80
DHC + 0.1
M16
16.50
16.43~16.73
18.60
19.00~19.40
DHC + 0.1
From the dimension tables on pages 18~20 of the Böllhoff catalogue HELICOIL Plus Thread technology for high-strength fastenings. The catalogue notes that D1HC is the critical dimension when choosing the drill, and that the hole mouth is countersunk 90° and deburred before tapping, with the countersink diameter DHC + 0.1 mm. Note that the drill for M6 is 6.3 and not 6, and 8.4 for M8, quite unlike a plain tapped hole.
Nominal length, minimum thread depth and maximum screw depth with the tang left in (Böllhoff range example, mm)
Thread
1.5d: t2 / t3
2d: t2 / t3
2.5d: t2 / t3
Coils W (2d)
M4
6.0 / 5.6
8.0 / 7.6
10.0 / 9.6
8.4
M5
7.5 / 7.1
10.0 / 9.6
12.5 / 12.1
9.7
M6
9.0 / 8.5
12.0 / 11.5
15.0 / 14.5
9.6
M8
12.0 / 11.4
16.0 / 15.4
20.0 / 19.4
10.6
M10
15.0 / 14.2
20.0 / 19.2
25.0 / 24.2
11.2
M12
18.0 / 17.1
24.0 / 23.1
30.0 / 29.1
11.7
M16
24.0 / 23.0
32.0 / 31.0
40.0 / 39.0
13.8
From pages 18~20 of the same catalogue. t2 is the nominal length, that is the minimum length of full installing thread in a blind hole and the minimum panel thickness for a through hole; t3 is the maximum screw depth with the tang left in. The insert sits t5 = 0.25~0.5P below the hole mouth when t2 is at its minimum. For volume work the catalogue advises at least one more pitch on t1 (minimum tapped hole depth, to DIN 76-1) and on t2.
Minimum wall thickness, referred to the major diameter of the installing thread. d nominal diameter, DHC major diameter of the installing thread, a remaining wall thickness, s width of the boss or wall around the tapped hole, s/2 distance from the hole centre to the outer edge. The boxed values are the guide figures: s_min = 1.75 × DHC, a_min = 0.375 × DHC; ** grey cast iron on requestSource: Böllhoff, HELICOIL Plus Thread technology for high-strength fastenings catalogue
s_min = 1.75 × DHC, a_min = 0.375 × DHC
s_min
Minimum width of the wall or boss around the tapped hole, mm
a_min
Minimum remaining wall outside the major diameter of the installing thread, mm
DHC
Major diameter of the installing thread, mm, as in the table above
From Minimum wall thickness, page 13 of the Böllhoff HELICOIL Plus catalogue. The original note: it applies to aluminium alloy castings and forgings with an insert engagement length of 1.5d, and the actual wall follows the service conditions. Example: M8 with DHC 9.62 needs s ≥ 16.8 mm and a ≥ 3.6 mm.
An M10×15 example. Top row: the HELICOIL Plus installed, left a through hole, middle a blind hole with the tang broken off, right a blind hole with the tang left in (the screw turns in 14.2 mm at most); bottom row: with the screw installed. The number 4130 010 0015 in the figure is the insert order numberSource: Böllhoff, HELICOIL Plus Thread technology for high-strength fastenings catalogue
Nominal length by parent material tensile strength and screw property class (HELICOIL Plus guide values)
Parent Rm N/mm²
Class 3.6/4.6, 4.8/5.6
Class 5.8/6.6
Class 8.8
Class 9.8
Class 10.9
Class 12.9
Class 14.9
≤100
1.5d
2d
3d
3d
—
—
—
>100~150
1.5d
2d
2.5d
2.5d
2.5d
2.5d
3d
>150~200
1d~1.5d
1.5d
2d
2d
2d
2.5d
2.5d
>200~250
1d
1.5d
1.5d
1.5d
2d
2.5d
2.5d
>250~300
1d
1d
1.5d
1.5d
1.5d
2d
2d
>300~350
1d
1d
1d
1.5d
1.5d
1.5d
2d
>350~400
1d
1d
1d
1d
1.5d
1.5d
1.5d
>400
1d
1d
1d
1d
1.5d
1.5d
1.5d
From Determination of nominal length, page 13 of the Böllhoff HELICOIL Plus catalogue, valid at 20 °C. To keep the column count down, the original 3.6/4.6 and 4.8/5.6 columns are merged here (they differ only in the >150~200 row, 1d and 1.5d), and the 6.8/6.9 column is left out, which differs from 5.8/6.6 only in the ≤100 row (2.5d). The premise is that the screw is the weaker part of the joint; the table applies to aluminium and to materials with a shear to tensile strength ratio of 0.6~0.7 (0.8~1.4 for some cast irons, from VDI 2230); the temperature limit is 300 °C for aluminium alloy and 100 °C for magnesium alloy. A shorter length may be taken where tests show it is sufficient.
Guide values of the prevailing torque of the Screwlock type (to ISO 2320, grade 8, N·m)
Thread
M4
M5
M6
M8
M10
M12
M16
1st installation max
0.90
1.60
3.00
6.00
10.5
15.5
32.0
1st removal min
0.18
0.29
0.45
0.85
1.5
2.3
4.5
5th removal min
0.12
0.20
0.30
0.60
1.0
1.6
3.0
From page 12 of the Böllhoff HELICOIL Plus catalogue; it applies to coarse and fine threads alike.
Confirm the applicationA tapped hole in aluminium, magnesium, a casting or fibre-reinforced plastic that is taken apart often or has to take a high-strength screw, or the repair of a damaged thread. A new design can also use an insert to reduce the screw size and the screw count.
Choose the type and materialA2 stainless free running for general work; the locking type where there is vibration (with class 8.8 screws and above); an aluminium insert in magnesium parts to prevent contact corrosion; Inconel or Nimonic for high temperature.
Set the nominal lengthRead the length for the parent material tensile strength and the screw property class (for example 1.5d for a cast aluminium of Rm about 200 to 250 with a class 8.8 screw). Important joints are calculated to VDI 2230 or tested.
Draw the installing threadSet the drill, the installing thread and the countersink from the maker table; the blind hole depth is the thread depth t2 (one more pitch for volume work) plus the tap chamfer and the room for chips. With the tang left in, the screw length must keep the engagement within t3.
Check the wall thicknessFor aluminium check the boss and the edge distance at s ≥ 1.75 DHC and a ≥ 0.375 DHC; for other materials confirm with the maker.
Installation steps, photographs a~i. Insertion of thread insert: screw the insert onto the installation mandrel with the tang downward (a), or drop it into the guide sleeve (b), or fit it on the fly-over tool used for large sizes (c), then line the tool up with the tapped hole. Installation: turn the threaded mandrel (d), the mandrel (e) or the fly-over tool (f), by hand or under power, until the insert is at least 0.25P below the hole mouth. Breaking off the tang: in a through hole the tang is broken at the notch with the tang breaking tool (g, h); from M14 it can be pulled out with needle-nose pliers (i); in a blind hole the tang may be left in as long as the screw does not go deeper than t3Source: Böllhoff, HELICOIL Plus Thread technology for high-strength fastenings catalogue
Drilling: use an ordinary twist drill of the size given in the table; countersink the hole mouth 90° and deburr it before tapping.
Tapping: the HELICOIL maker's tap must be used (a forming tap gives a chipless thread as an alternative), and the installing thread is checked with the HELICOIL thread plug gauge. The catalogue notes for some machine taps that a blind hole needs enough room for chips, at least 1d deeper than the full thread length.
Screwing in: once installed the insert sits at least 0.25P below the hole mouth, commonly 0.25 to 0.5P.
Breaking the tang: in a through hole, or a blind hole where the screw goes right to the bottom, break the tang at the notch with the breaking tool and take the piece out, so that it does not drop into the machine; from M14 upward use needle-nose pliers.
Impact drivers: ask the maker before tightening screws with an impact wrench.
Repair: the Böllhoff repair kit holds inserts in three lengths, drills (to M12), hand taps, installation mandrels and tang breaking tools (to M12).
07Failure modes and maintenance
Common problems, causes and actions
Symptom
Likely cause
Action
Insert turns out with the screw
Installing thread oversize (wrong tap or drill)
Use the maker's tap and check the installing thread with a gauge
Screw will not enter or seizes
Tang not broken with a screw that is too long; insert not seated, first turn standing up
Break the tang or shorten the screw to within t3; set the insert 0.25P below the hole mouth
Thread pulled out of the parent
Nominal length too short; parent material weaker than assumed
Lengthen to the length table or run a test
Hole edge cracks
Wall thickness too small
Enlarge the boss to the s and a guide values
Corrosion around a magnesium part
Potential difference between the stainless insert and the magnesium
Change to an aluminium insert with corrosion protection
Compiled from the notes on pages 9, 12, 13 and 16~17 of the Böllhoff HELICOIL Plus catalogue.
A damaged insert can be taken out with the special extraction tool (page 55 of the catalogue lists the breaking and extraction tools) and a new one of the same size installed; the parent thread is normally unaffected.
08Common design mistakes
Drawing a plain tapped hole as the tap drill. An M6 insert needs a 6.3 hole and a HELICOIL installing thread, not a 5.0 hole tapped M6.
Sizing the wall from the screw diameter. The installing thread major diameter is one size above the screw (7.30 on M6, 9.62 on M8), so the boss is set from DHC.
Blind hole too shallow. The chamfer of the special tap and the room for chips were not counted, and the insert cannot reach the required depth.
Locking type with a low-grade screw. The catalogue allows class 8.8 and above only.
Leaving the tang in a through hole. The tang blocks the screw or drops into the mechanism.
09Standards and manufacturer ranges
Standards quoted in the sources
Standard
Subject
DIN 8140
Wire thread inserts (HELICOIL Plus and Classic comply)
DIN 65536, LN 9039, LN 9499
Wire thread inserts for aerospace
NAS 1130, NAS 0276
Aerospace standards met by the tangfree type
NASM 21209
UNC and UNF wire thread inserts
DIN 13 (6H, 4H)
Internal thread accuracy after installation
ISO 2320
Prevailing torque requirements for the locking type
DIN 76-1
Tapped hole depth (guide value for t1)
VDI 2230
Calculation of bolted joints, source of the shear to tensile strength ratio in the length table
From pages 6, 7, 10, 12, 13 and 18 of the Böllhoff HELICOIL Plus catalogue. The current Chinese standard number for wire thread inserts was not checked for this article.
Böllhoff HELICOIL: Plus, Classic, Tangfree and Smart ranges, with hand, electric, pneumatic and automated installation tools, and free CAD downloads.
The US market also has the Heli-Coil brand of STANLEY Engineered Fastening. Inserts, taps and gauges of different brands are best kept as a set.
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-20