Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
A manual positioning stage made of three mechanisms, guide, feed and clamp, used to bring cameras, sensors, optical fibres and fixtures into position and lock them there. Select the guide first by accuracy (dovetail, crossed roller, linear ball), then the feed by resolution, and finally check load, moment, mounting orientation and clamping force.
01Construction and how it works
A precision adjustment stage (manual positioning stage, Manual Stage) consists of a fixed side (base plate), a moving side (table) and three mechanisms: the guide sets the path the table follows and how straight it is; the feed (micrometer head, lead screw, rack and pinion) turns hand rotation into table movement and gives a reading; the clamp fixes the adjusted position. It is a part that "stays put once adjusted", not a motion axis, used to adjust positions for camera positioning, fibre alignment, inspection samples, analysis fixtures and production line changeovers.
Crossed roller and linear ball guide stages have an internal tension spring that pulls the table against the micrometer head spindle, so the table follows the micrometer back when it is retracted. The micrometer head can therefore only "push", not "pull"; when the table is mounted vertically with the load acting in the "pull" direction, the table slides down once the load exceeds the spring force (see the installation section). The micrometer head itself produces no thrust; the force comes from the operator, and MISUMI does not guarantee the load capacity of a micrometer head on its own.
Three guide mechanisms (left to right): dovetail (Male Dovetail, Female Dovetail, trapezoidal section with sliding surface contact); crossed roller (cylindrical rollers alternately crossed between V-grooves in the upper and lower plates); linear ball (steel balls rolling in Gothic arc grooves machined directly in the upper and lower plates)Image source: MISUMI USA, Positioning Stages feature, What are stages
Male and female trapezoidal sections, sliding surface contact, clearance adjusted by gib
Cylindrical rollers alternately crossed between V-grooves
Steel balls rolling in Gothic arc grooves machined in the body
Main material
Brass / aluminium alloy
Aluminium alloy
Stainless steel
Stiffness
Good
Good
Excellent
Motion accuracy
Fair
Good
Excellent (grooves integral with the body)
Body weight
Light
Light
Heavier
Travel
Very long
Medium
Medium
Price
Very low
Medium
High
Feel
Sliding resistance, suited to coarse adjustment
Smooth, suited to fine adjustment
Smoothest
Applications
Low cost, long travel, no micrometre accuracy needed
Cost-effective precision positioning
Highest accuracy, high stiffness, high load, long life
MISUMI USA What are stages guide comparison table (three grades: Excellent/Good/Fair). Dovetail sliding surfaces have clearance, and MISUMI gives no moment stiffness or static load for them (FAQ A3, technical data "static load" item).
Feed types and resolution
Feed
Principle
Minimum reading
Travel per knob turn
Features
Rack and pinion
Pinion drives rack
Depends on the table scale
17 to 20 mm
Long travel, fast movement
Lead screw (fine-thread screw)
Screw and nut
Depends on the table scale
0.5 to 10 mm selectable
Saves space compared with a micrometer head, lead selectable by use
Micrometer head
Micrometer screw, graduated thimble
10 μm
0.5 mm or 1 mm
Precision adjustment at reasonable cost
Coarse/fine micrometer head
Double thimble, coarse + fine
Coarse 10 μm / fine 0.5 μm
Coarse 0.5 mm / fine 0.025 mm
Finest; fine travel only 0.2 mm
Digital micrometer head
With digital display
1 μm
0.5 mm
Reading does not depend on the eye
MISUMI USA What are stages feed mechanism table and FAQ A10~A14. The travel per knob turn column is merged in the original layout; the micrometer head value follows "XCRS micrometer knob 0.5 mm per turn" in the FAQ.
Clamping types
Clamp
Method
Holding force
Features
Standard clamp
Clamp screw presses a clamp plate against the table
Fair
Low cost, general purpose
Dovetail standard clamp
Internal dovetail clamp plate pressed by a screw
Fair
Low cost
Lever type
Lever fitted on the clamp screw
Good
No tools needed, locks with little force
Split clamp (shaft clamp)
Clamps the feed shaft directly
Excellent
Locks the feed knob as well
Disc clamp
Clamping force applied to a disc outside the table
Good
The disc is separate from the table, so clamping does not shift position; can be combined with the standard clamp against drift
Opposed clamp
Bolt and nut as a hard stop opposite the feed
Excellent
Resists vibration
MISUMI USA What are stages clamp mechanism table. Most clamps rely on friction, and the table moves if external force exceeds friction; the split clamp and opposed clamp are designed to prevent this.
03Key parameters
Meaning and measurement of accuracy terms
Term
Meaning
Measurement
Straightness
Maximum deviation of the table's path from an ideal straight line in the horizontal and vertical planes over the full travel, μm
Measure at fixed intervals while moving, take the maximum difference from the ideal line
Motion Parallelism
Height variation of the table relative to the base over the full travel, μm
Dial indicator fixed on the table, stylus on the reference base, take the maximum difference over the full travel
Parallelism (static)
Parallelism of the table to the mounting base at the reference position, μm
Measured with the table stationary at the reference position; not a motion accuracy metric
Pitch
Nose up/down in the vertical plane along the direction of motion, arc seconds (″)
Measure angle at fixed intervals over the full travel
Yaw
Swing left/right in the horizontal plane, ″
As above
Roll
Tilt left/right in the plane perpendicular to the direction of motion, ″
Often cannot be measured in motion, generally not listed as an accuracy metric
Moment stiffness
Angle the table tilts under a moment of 1 N·cm, ″/(N·cm)
Given separately for pitch, yaw and roll
MISUMI USA Technical Info, motion accuracy and moment sections. 1″ = 1/3600° ≈ 0.00028°. Motion accuracy of multi-axis stages (such as XY) is measured per single axis.
The three angular errors of the table: Pitching (about the transverse axis, nose up/down along the direction of motion), Yawing (about the vertical axis, swinging in the horizontal plane), Rolling (about the axis of motion, tilting left/right)Image source: MISUMI USA, Positioning Stages feature, Technical Info
Linear ball micrometer stage XSG series (series example, high precision)
Table mm
Horizontal load N
Straightness μm
Motion parallelism μm
Pitch / yaw
Permissible moment pitch/yaw/roll N·m
Moment stiffness ″/(N·cm)
Weight kg
25 × 25
39.2
3
10
30″ / 25″
2.0 / 2.0 / 3.5
1.9 / 1.1 / 1.1
0.07
40 × 40
98
1
7
25″ / 15″
5.0 / 5.0 / 5.0
0.42 / 0.35 / 0.21
0.23
60 × 60
196
Per catalogue
Per catalogue
Per catalogue
10.0 / 10.0 / 9.0
0.08 / 0.08 / 0.05
0.40
80 × 80
264.6
3
8
Per catalogue
18.2 / 18.2 / 17.7
0.04 / 0.04 / 0.02
0.90
100 × 100
343
Per catalogue
Per catalogue
Per catalogue
31.8 / 31.8 / 30.7
0.02 / 0.02 / 0.01
1.33
MISUMI USA Technical Info example table (XSG micrometer type). The web table has merged cells; cells that could not be determined are marked "per catalogue". Vertical load 9.8 N for size 25 and 49 N for size 40; static parallelism 30 μm for size 25, 15 μm for size 40, 20 μm for size 80.
Crossed roller micrometer stage XCRS series (series example, standard grade)
Table mm
Horizontal load N (static load reference)
Vertical load N
Straightness / motion parallelism
Permissible moment pitch/yaw/roll N·m
Parallelism (static)
Clamp holding force (reference)
40 × 40
19.6 (49)
9.8 (49)
30 μm / 30 μm
2.7 / 2.2 / 2.0
50 μm
60 N
60 × 60
49 (196)
19.6 (49)
30 μm / 30 μm
5.2 / 4.3 / 5.5
50 μm
60 N
80 × 80
98 (392)
49 (49)
30 μm / 30 μm
19.2 / 15.1 / 17.3
60 μm
70 N
120 × 120
196 (588)
49 (49)
30 μm / 30 μm
57.2 / 44.7 / 66.7
60 μm
70 N
MISUMI 2019 US catalogue P.2016, [Standard] Cross Roller X-Axis Stages. Micrometer head 10 μm per division, 0.5 mm per knob turn. Clamp holding force varies with tightening torque, so leave margin in design. Compared with the table above: at the same size 40, the high-precision linear ball stage has 1 to 3 μm straightness and the standard crossed roller stage 30 μm, an order of magnitude apart.
MISUMI micrometer heads (individual)
Model
Travel mm
Minimum reading μm
Load reference value N
MCLN1 / MCLN2 / MCLN3
±3.25
10
9.8
MCLN4
±3.25
5
15
MCLN6
±6.5
10
49
MCLN12
±12.5
10
Per catalogue
MCLN83 coarse/fine
Coarse ±6.5, fine 0.2
Coarse 10, fine 0.5
Per catalogue
MCLN84 digital
0 to 25
1
Per catalogue
MISUMI USA FAQ A10 and A12 (reference values, not guaranteed). For ±6.5 mm travel, scale 0 corresponds to -6.5 mm, scale 6.5 to the middle of travel and 13 to +6.5 mm (A11).
04Selection steps and calculation
Define adjustment requirementsTravel, minimum adjustment needed, whether readings must be reproducible after adjusting (for adjusting by numbers at changeover choose a scale or digital display).
Define the guideMicrometre level and smooth: linear ball or crossed roller; millimetre coarse adjustment, long travel, low cost: dovetail.
Define the feedMicrometer head for 10 μm level, coarse/fine head for sub-micrometre, rack and pinion for fast long travel, lead screw where space is tight.
Check load and momentWith the load at the table centre look at load capacity; with the centre of gravity off-centre look at permissible moment, and estimate tilt with moment stiffness.
Check mounting orientationInverted, side and vertical mounting derate load capacity, and vertical mounting must have the micrometer head taking the load direction.
Define clamp and feed positionWith vibration or external force choose a split clamp or opposed clamp; choose the micrometer head position code by operating space.
Effect of mounting orientation on load capacity (MISUMI reference values)
Type
Typical models
Inverted
Side mounted (horizontal / vertical)
Dovetail lead screw
XFES, XSL, XEG
Usable
Conditional
Dovetail rack and pinion
XDTS, XWG, XFG
Conditional
Conditional
Crossed roller
XCRS, XPG
Conditional
Conditional
Linear ball
XLBS, XSG
Conditional
Conditional
Crossed roller horizontal Z stage
ZLPG
Not usable
Not usable
MISUMI USA FAQ B3. "Usable" = same as horizontal load capacity; "Conditional" = about 1/3 of horizontal load capacity; where the catalogue lists vertical load capacity, the catalogue governs. Conditions: workpiece centre of gravity no more than 1/2 the table side length from the table centre (such as 20 mm for □40), centre of gravity within the table, travel at the midpoint.
θ = K_m × M
θ
table tilt angle, arc seconds (″)
K_m
moment stiffness, catalogue value for pitch, yaw or roll, ″/(N·cm)
M
moment from the eccentric load = load × distance from centre of gravity to table centre, N·cm
Per the definition of moment stiffness in MISUMI Technical Info (tilt angle per unit moment). Example: XSG40 pitch stiffness 0.42″/(N·cm), a 10 N camera with its centre of gravity 3 cm off-centre, M = 30 N·cm, table tilts about 12.6″.
φ = arctan(Δ / R) × (180/π) × 3600
φ
rotation angle, ″
Δ
micrometer head feed, mm
R
distance from the centre of rotation to the micrometer head, mm
MISUMI FAQ B7 rotary stage example: RPG60 has R = 37.5 mm, one micrometer division of 0.01 mm gives rotation angle = arctan(0.01/37.5) × (180/π) × 3600 ≈ 55″. The same trigonometry used in reverse estimates Abbe error: the height of the measured point above the guide times the tangent of the pitch or yaw angle is the extra displacement at that point; XSG25 pitch of 30″ gives about 7 μm at 50 mm above the table, more than its 3 μm straightness. So keep measuring points, tool tips and optical axes as close to the table as possible for fine adjustment.
05Installation, adjustment and use
Mounting surface flatness within 0.01 mm: if the stage is mounted on an uneven surface, or parts mounted on the table are uneven, the body is twisted into a U shape; guide preload loosens and it wobbles, or with the opposite distortion preload becomes excessive, it feels stiff, and accuracy and life fall. If it becomes rough after mounting, check this first.
Screw length must not exceed the depth of the tapped holes in the table: screws that are too long hit internal parts, causing stiffness or seizure.
Mounting sequence: first move the table aside to expose the mounting holes in the base plate, then fit the screws.
Vertical or inverted mounting: the micrometer head must take the load direction, otherwise the table slides down when load exceeds the internal spring force; for vertical mounting choose codes such as CZ and AZ with "up/down reversed" (spindle facing up, load bearing on the spindle), or make sure the load acts towards the micrometer head.
Clamping can shift position: the force of tightening the clamp screw may move the table, so re-measure after fine adjustment; where position drift matters choose a disc clamp.
Assembling multi-axis stages yourself: MISUMI allows XY and XZ to be assembled with screws, but perpendicularity of self-assembled stages is not guaranteed and must be aligned with a square or dial indicator (see the XY stage entry).
Do not replace micrometer heads, lead screws, knobs or clamp knobs yourself: it affects accuracy and voids the original warranty. Use a knob cover for a thicker knob and an extension sleeve for a longer one.
Environment: use at 10 to 50 °C and 20% to 70% RH non-condensing, 22 ± 5 °C recommended; avoid metal dust, direct sunlight and heat sources, oil and water, vibration and shock. There are no dust-proof types, nor types usable in water.
Magnetism: stainless steel bodies are affected by magnetic forces on base and table; where magnetism matters use aluminium alloy bodies (their screws and nuts may still be magnetic).
Lubrication: no fixed interval; check the grease about once a month, and when needed wipe off old grease, apply with a syringe to the guide, run the full travel a few times and wipe off the excess. Do not wash the grease out.
Vertical mounting of X-axis stages: left, with Normal, CR, A and AR codes and the micrometer head facing down, the table slides down when the load (lbs) exceeds the internal spring force, so the micrometer head must support the load (STOP!!); right, micrometer head orientation of each code in vertical mounting: CZ and CZR are up/down reversed types with the spindle facing up, the load being taken by the micrometer head and the bracket on the base plateImage source: MISUMI USA, Positioning Stages feature, Technical InfoMicrometer head position options (Alteration · Micrometer Head Position): CR side mounted, left/right reversed; A centre; AR centre, left/right reversed; AZ centre, up/down reversed; AZR centre, both left/right and up/down reversed. The standard position is side mountedImage source: MISUMI 2019 US catalogue P.2016, [Standard] Cross Roller X-Axis Stages
Reading: on a micrometer head first read the whole 0.5 mm graduations exposed on the sleeve, then the thimble graduation aligned with the reference line (0.01 mm per division), and add them, for example 11.5 + 0.36 = 11.86 mm. On a vernier first read the whole millimetre on the main scale opposite the vernier 0 line, then find the vernier division aligned with the main scale (in 0.1 mm units), for example 30 + 0.6 = 30.6 mm.
06Failure modes and maintenance
Common problems, causes and remedies
Symptom
Cause
Remedy
Wobble, rough feel, accuracy worse
Uneven mounting surface or table-mounted parts, body distorted
Make mounting surface flatness within 0.01 mm, check parts mounted on the table
Rougher after mounting than before
Uneven mounting surface; screws too long, hitting internals
Check flatness, use shorter screws
Table does not return when the micrometer is retracted
Clamp not released (the table returns by spring)
Release the clamp first
Table does not move when the micrometer is turned
Clamp not released
Release the clamp, then adjust
Still moves after clamping
External force exceeds clamp friction
Change to an opposed clamp or split clamp
Table slides down when mounted vertically
Load direction away from the micrometer head, exceeding spring force
Change to an up/down reversed code so the micrometer head takes the load
Rack and pinion stage hits the travel end
Beyond catalogue travel, hitting the stop
Use within travel; excessive force damages the stop
Reduced guide life
Lack of grease, dust
Check grease monthly, avoid dusty environments
MISUMI USA FAQ E1~E4, B6 and A7 and the installation and maintenance section of Technical Info. MISUMI gives no life figure for manual stages; life depends on environment, loading and frequency of use (FAQ A4).
07Common design mistakes
Using standard grade as high precision. At the same size 40, the standard crossed roller stage has 30 μm straightness and the high-precision linear ball stage 1 to 3 μm; standard grade gets its low price by relaxing the guaranteed accuracy conditions (FAQ A1).
Looking at load but not moment. With the centre of gravity off the table centre, permissible moment is reached first, and the table tilts according to its moment stiffness.
Ignoring micrometer head direction when mounting vertically. The table is pulled back by a spring, and drops if the load exceeds the spring force.
Using the micrometer head as a thrust element. It produces no thrust, and its load reference value is only 9.8 to 49 N.
Measuring point too high above the table. Pitch and yaw angles are magnified by height into Abbe error.
Assuming position does not change once clamped. Tightening the clamp itself may shift the position, and it can still move if external force exceeds friction.
Assembling an XY yourself without aligning perpendicularity. The maker does not guarantee perpendicularity of self-assembled stages.
Using it directly in dusty, oily or wet environments. Manual stages have no dust-proof type; add a cover or relocate.
08Related standards and maker series
No dedicated Chinese national standard for manual positioning stages was found in the documents used for this article; accuracy follows each maker's definitions and measuring methods (see the key parameters section). Micrometer heads follow JIS B 7502:2016 (cited in MISUMI FAQ A10), and catalogue dimensions without tolerances are to be read as the medium class of JIS B 0405:1991 (tolerance section of Technical Info).
MISUMI: dovetail XFES, XSL, XEG (lead screw), XDTS, XWG, XFG (rack and pinion); crossed roller XCRS (standard), XPG (high precision); linear ball XLBS, XSG, XSCG, FSXR; coarse/fine XSKG, digital XSDG; simple adjustment units XKNEJ, XKNG, XKS and others.
Other makers: Thorlabs, Newport, Suruga Seiki, Chuo Precision Industrial, OptoSigma and others all make manual positioning stages; models and accuracy definitions differ from maker to maker, so follow their catalogues.
MISUMI USA, Positioning Stages feature, Technical Info ↗Travel, load and static load definitions, motion accuracy terms and measurement, permissible moment and moment stiffness, tolerances, micrometer head positions, mounting orientation, mounting surface flatness, reading methods, operating environment and maintenance
MISUMI USA, Positioning Stages feature, FAQ ↗A1 standard and high precision, A3 dovetail stiffness, A10~A16 micrometer heads and clamps, B3 mounting orientation, B4 multi-axis combinations, B6 roughness after mounting, B7 rotary stage angle example, E1~E5 faults
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-17
ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN
Buying and using: calculators, sellers, uses
The notes below cover the “Manual stages & lifts” category. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.
TOOLS / CALCULATE
Related selection calculators
Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.
The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. Price comparison and ranking are not available yet.
MISUMIFactory automation and tooling components with selection and CAD resources.