A magnetic tool that switches its magnetic circuit by an electrical signal and holds the workpiece by permanent magnet force.
02 / CONSTRUCTION
Construction & recognition
Consists of permanent magnet assemblies, poles and a switching mechanism. The end effector shown is electrically driven, and the poles can be changed to suit the workpiece.
03 / APPLICATIONS
Common applications
Picking and placing ferromagnetic sheet or workpieces, and as a magnetic chuck for clamping.
Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
An electro-permanent magnet reverses an internal switchable permanent magnet with a short current pulse to grip or release steel parts; holding force needs no continuous coil current, and the established field is kept at power-off. Whether the workpiece is actually held securely depends on forces, air gap and contact. Taking the Goudsmit HGE-SQ-070 robot electro-permanent gripper as an example: 24 V DC supply, 6 A peak for 350 ms when switching and only 30 mA otherwise; on low-carbon steel of 8 mm or more with an air gap under 0.1 mm the recommended working load is 33 kg (already including the EN 13155 safety factor of 3), falling to 8 kg at an air gap of 0.25 to 0.5 mm. Select by looking up the maker's tables for workpiece thickness, material, surface air gap and acceleration, then leave an adequate safety factor.
01Construction and how it works
An electro-permanent (makers also write permanent-electro, electro-permanent or bi-stable) magnet contains two kinds of permanent magnet: one with high coercivity and fixed direction, the other remagnetisable in reverse by a current pulse in a coil. In the lifting modules of MAG-Autoblok Tecnomagnete, for example, the fixed magnet is NdFeB and the reversible one is AlNiCo, with the reversing coil wound around the AlNiCo.
Grip (MAG): a pulse to the coil aligns the AlNiCo magnetisation with the NdFeB, and the flux of both leaves through the pole faces and closes through the workpiece, which is held.
Release (DEMAG): a reverse pulse flips the AlNiCo, the flux closes inside the module, the pole faces have almost no magnetic force, and the workpiece is released.
Holding uses no power: Tecnomagnete states that the magnetic force is produced entirely by the permanent magnets in the module, and electricity is used only for a few seconds to switch the flux direction; both MAG and DEMAG states are held indefinitely without power.
Cross-section of an electro-permanent lifting module. Left: MAG state, flux closes through pole 4 and workpiece 5; right: DEMAG state, flux closes inside the module. 1 NdFeB permanent magnet, 2 reversible AlNiCo permanent magnet, 3 module housing (neutral outside), 4 pole (flux collector), 5 steel load, 6 reversing coil of the AlNiCo.Image source: MAG-Autoblok Tecnomagnete, Permanent-electro magnetic systems – TECNOLIFT line, page 3
Compared with an electromagnet: an electromagnet produces force with continuous coil current and releases at power-off (see the electromagnet entry); an electro-permanent magnet is energised only when switching and keeps its state at power-off. Tecnomagnete therefore says electro-permanent lifting systems need no backup battery, and with no continuous heating the holding force does not fall during the day from coil temperature rise.
02Types and specification system
Types of electro-permanent equipment by application
Type
Examples
Features
Robot electro-permanent gripper
Goudsmit HGE-SQ-052/070/090; SCHUNK EMH-RP 045-B
24 V DC, built-in control electronics; workpiece detection and status feedback, some with adjustable force
Electro-permanent lifting magnet (lifting device)
Walmag Neo EP (NEOSQ300 to NEOSQ4000); Tecnomagnete TECNOLIFT SMH, TM, BF
Hung on overhead cranes to lift plates and billets; switched by push button or remote control; Neo EP series maximum lift 4000 kg
Internal permanent magnet turned by an actuator to any position from 0 to 100% (spec sheet: Magnet Position 0–100%, homes to zero on power-up), Fail-Safe when fully on; not coil pulse reversal, but likewise holds at power-off
From the makers' catalogues and product pages. Kendrion's "Permanent Electro Holding Magnet" works the opposite way: it holds when de-energised and releases only when energised; check its 25% ED by the method in the electromagnet entry.
Goudsmit HGE-SQ electro-permanent grippers (24 V DC)
Model
Maximum pull-off force
Maximum shear force (without / with friction ring)
Outline depth × width × height
Weight
HGE-SQ-052
420 N
105 N / 140 N
72 × 57 × 101 mm
1 kg
HGE-SQ-070
900 N
225 N / 300 N
89 × 70 × 105 mm
1.9 kg
HGE-SQ-090
2160 N
540 N / 720 N
106 × 96 × 125 mm
4.1 kg
From the three HGE-SQ rows of Goudsmit Pneumatic Gripper Selection Guide V2 (2025-07-22); operating temperature 5 to 40 °C, adjustable force, suitable for destacking. Shear force is about 1/4 of pull-off force, about 1/3 with a friction ring.
HGE-SQ recommended working loads: plate thickness and air gap (low-carbon steel, safety factor 3 included, no friction ring)
Model
Plate thickness
Air gap < 0.1 mm
0.1 to 0.25 mm
0.25 to 0.5 mm
HGE-SQ-052
≥ 1 mm
3 kg
2 kg
2 kg
HGE-SQ-052
≥ 3 mm
10 kg
6 kg
4 kg
HGE-SQ-052
≥ 5 mm
15 kg
7 kg
4 kg
HGE-SQ-070
≥ 3 mm
12 kg
9 kg
6 kg
HGE-SQ-070
≥ 5 mm
24 kg
15 kg
7.5 kg
HGE-SQ-070
≥ 8 mm
33 kg
17 kg
8 kg
HGE-SQ-090
≥ 5 mm
30 kg
25 kg
18 kg
HGE-SQ-090
≥ 8 mm
53 kg
36 kg
19 kg
HGE-SQ-090
≥ 12 mm
75 kg
41 kg
20 kg
Goudsmit User instructions E-Gripper v4.0, "Advised working loads" table: weights that can be lifted under ideal conditions, with a safety factor of 3 already included per EN 13155. Values are slightly lower with a friction ring, for example 30 kg for HGE-SQ-070, ≥8 mm, <0.1 mm.
Three rules can be read from this table: thin plates cannot use the full force (Goudsmit explains that thin plates saturate magnetically, so the field cannot be used); air gap matters more than thickness, with a 0.25 to 0.5 mm gap taking HGE-SQ-070 on 8 mm plate from 33 kg down to 8 kg; larger sizes only pay off on thick plate, and a bigger gripper does nothing for 1 mm plate.
Magswitch ELAY30x5 maximum force versus plate thickness (SAE 1018)
Plate thickness / mm
0.6
1.0
1.5
2.0
3.0
4.0
5.0
6.0
7.0
9.5
50
Maximum force / N
263.8
536.4
654.1
862.0
1016.0
1274.9
1646.5
1803.4
2002.5
2185.9
2186.9
Magswitch ELAY30x5 spec sheet (1101464 r06), page 1: laboratory conditions, SAE 1018 steel, surface roughness 63 µin, standard pole shoes; values may vary by ±5%. The maker states these are **not safe lifting forces**: safe working load SWL = maximum force / safety factor, with 3:1 recommended for most lifting.
Effect of material on holding force (Goudsmit)
Workpiece material
Force relative to low-carbon steel
Unalloyed low-carbon steel (<0.3% C), such as Fe 360, Fe 510
100%
Unalloyed carbon steel (0.3 to 0.5% C), such as C15, C45
80 to 90%
High-carbon alloy tool steel (0.5 to 1.8% C)
70 to 80%
Magnetic stainless steel (ferritic, martensitic), such as AISI 430
60 to 75%
Cast iron (>1.8% C)
45 to 50%
Nickel
30 to 50%
Stainless steel AISI 304
1 to 3%
Austenitic stainless steel such as AISI 316; brass, aluminium, copper
0%
Goudsmit E-Gripper user instructions v4.0 and Feasible magnetic forces E-Grippers. The two documents give the carbon content of high-carbon steel differently (0.5 to 1.8% and 0.5 to 0.8%).
Switching current and time: HGE-SQ switching peak maximum 6 A for 350 ms, 30 mA otherwise; SCHUNK EMH-RP 045-B maximum current 3.8 A, logic current 0.15 A, actuation time 300 ms; Magswitch ELAY30x5 inrush current 3 A (70 ms), peak 2.5 A, continuous 1 A.
Switching frequency and temperature rise: HGE-SQ allows 12 grips plus 12 releases per minute, and no more than 12 per minute above 30 °C ambient; Goudsmit explains that more than 4 per minute heats the internal magnetic circuit and reduces force. SCHUNK EMH-RP 045-B rises 11 °C at 5 cycles per minute and 28 °C at 15.
Temperature: ambient above 30 °C and workpiece temperatures of 40 to 80 °C both reduce holding force (Goudsmit); Walmag Neo EP lifting magnets up to 80 °C, 100% duty.
Acceleration: HGE-SQ with friction ring allows 20 m/s² in all directions, provided there are no other weakening factors.
04Outline, interfaces and installation space
Taking the Goudsmit HGE-SQ-070 as an example: outline 89 × 70 × 105 mm (depth × width × height), 1.9 kg, fixed from the top face with 4 screws to the robot flange or an adapter plate; one socket on the side takes a single "power + signal" cable, bought separately in straight or angled versions; the angled one projects along the side, so leave room around robot axis 6 for the connector and cable bend. The underside is the pole face, with a replaceable NBR friction ring (Shore 70 A) around the outer pole.
Mounting the HGE-SQ electro-permanent gripper: 4 socket head screws on the top face fix it to the robot side, the angled cable plugs into the side, and the black part at the bottom is the replaceable friction ring.Image source: Goudsmit Magnetics, User instructions E-Gripper, HGE-SQ-xxx-FR-EP-P-I v4.0, page 1, Installation and commissioning
HGE-SQ cable core assignment
Core
Cross-section
Function
Notes
Red / black
2.5 mm²
+24 V DC / 0 V
Maximum 6 A for 350 ms when switching, 30 mA otherwise; undervoltage <21.6 V, overvoltage >29 V protection
White
0.25 mm²
DI1 grip
24 V, 10 ms pulse
Green
0.25 mm²
DI2 release
24 V, 10 ms pulse
Yellow
0.25 mm²
AI1 force setting (optional)
1 to 10 V for 10% to 100%, 100% if unused
Grey / pink / violet
0.25 mm²
DO1 magnet status / DO2 workpiece present / DO3 fault
24 V, 4 mA; 0 V means gripped, workpiece detected and fault present respectively
Braided shield
2.5 mm²
Shield
Must be earthed
Goudsmit E-Gripper user instructions v4.0, Wiring table.
Size the supply for the peak: average current is small, but 6 A at the moment of switching. Goudsmit explains that if voltage dips when switching, raise the supply voltage or use a supply with higher current. Peaks add when several grippers switch together, and long, thin cables also cause voltage drop; when routing through the robot dress pack, check voltage drop on the 2.5 mm² power cores.
SCHUNK EMH-RP 045-B: 64 × 64 × 128 mm, 1.5 kg, IP52, 5 to 50 °C, control electronics built in.
Magswitch ELAY30x5: pole face 186.2 × 41 mm, 5.7 kg, 6 M6 mounting holes on each side, M12 5-pin A-coded connector (CANopen), -10 to +40 °C. The maker warns: do not actuate when not in contact with steel.
Walmag Neo EP for lifting: NEOSQ300 outline 164 × 164 × 420 mm, 4 poles (pole blocks 50 × 50 mm), effective magnetic face 116 × 116 mm, 23 kg; NEOSQ1000 outline 228 × 228 × 295 mm, 39 kg.
Safety distances: Goudsmit warns that steel parts within 10 cm can be pulled in as "projectiles", and to keep at least 25 cm from active implants such as pacemakers; do not use the gripper where a falling workpiece could injure people, and provide guarding.
Degree of protection: HGE-SQ is IP40; at stations with a lot of coolant or weld spatter add protection or choose a product with a higher degree of protection.
05Selection steps and calculation
1 Define the workpieceMaterial (look up the material factor table), thickness, size of the flat contact area, surface condition (paint, plating, rust, scale, chips and films all count as air gap), whether it has holes, whether it will sag.
2 Define the direction of forceLifting with the pole face down loads it in pull-off; holding with the pole face vertical relies on friction and loads it in shear. In the maker's HGE-SQ example, shear force without friction ring is 105 N against 420 N pull-off. For vertical holding, check shear load separately for the model and contact conditions. The SCHUNK EMH-RP 045-B product page gives 22.5 kg with a horizontal pole face and 9.0 kg with a vertical one.
3 Calculate the force neededAdd gravity to the maximum acceleration in motion and multiply by the safety factor. When using a maker's working load table that already includes the safety factor (such as Goudsmit), do not multiply again, but check acceleration separately.
4 Look up the maker's tableFind the working load in the cell for the thickness and air gap, multiply by the material factor, then discount for the actual contact area.
5 Confirm the cycleCheck temperature rise and permissible frequency against switching cycles per minute; derate for high ambient temperatures and hot workpieces.
6 Define the controlUse status feedback (gripped, workpiece present, fault) for interlocks: grip only when the workpiece is present, move only after grip is confirmed, and stop immediately if the workpiece-present signal disappears in motion.
F_N ≥ m · (g + a) · S; F_V ≥ m · (g + a) · S
F_N
maximum pull-off force given by the maker, N
F_V
maximum shear (slip) force, N
m
workpiece mass, kg
g
9.81 m/s²
a
maximum acceleration in motion in the direction of the force on the pole face, m/s²
S
safety factor: Magswitch recommends 3 for lifting; Goudsmit takes 3 per EN 13155; Walmag Neo EP is 3:1
The second inequality applies with a vertical pole face, with F_V taken from maker data for the actual contact conditions. F_N and F_V must first be corrected for workpiece thickness, air gap, material and contact area.
1 Mechanical mountingFix at the maker's hole positions, with the pole face parallel to the workpiece resting surface. Where the workpiece surface is uneven or has bosses, use a compliant connection (Goudsmit recommends compliant mounting and several grippers for workpieces prone to sagging).
2 WiringWire with power off, lock the connector against loosening; earth the braided shield. Choose the supply for the switching peak and several units switching together.
3 Trial gripPlace the gripper on the workpiece and confirm the "workpiece present" feedback appears first (HGE-SQ lamp turns light blue) before sending the grip pulse. Goudsmit explains: if the lamp does not turn light blue when placed, the air gap may be too large or the workpiece have too many holes, so improve contact.
4 Set the forceWhen destacking thin plates, lower the force with the analogue input (HGE-SQ 1 to 10 V for 10% to 100%) so only one sheet is picked at a time.
5 VerifyTest with the actual workpiece, actual surface condition and maximum acceleration; Magswitch and Goudsmit both require testing in each application, and consulting the maker when in doubt.
07Failure modes and maintenance
Common problems, causes and remedies
Symptom
Possible cause
Remedy
Workpiece drops in motion (HGE-SQ reports Product lost)
Large air gap (paint, rust, oil, chips); thin plate; incomplete contact; excessive acceleration; sagging edges of flexible plates causing "peeling"
Clean contact faces; recalculate from the table; reduce acceleration; add grippers and support points
Holding force gradually falls
Frequent switching heats the internal magnetic circuit; high ambient or workpiece temperature
Reduce switching frequency (heating begins above 4 per minute); derate for high temperatures
Switching fails, power supply fault reported
Voltage dip at the moment of switching
Raise supply voltage or use a higher-current supply, use thicker power cables
Overtemperature alarm
High ambient temperature plus frequent switching
Recovers automatically after cooling; no more than 12 per minute above 30 °C
Workpiece slips when held vertically
Relying on shear force alone, about 1/4 of pull-off force
Fit a friction ring; change to pole face down; add mechanical stops
Friction ring wear
Long-term use
Replace the NBR friction ring with the maker's spare
Compiled from the fault and influencing factors sections of Goudsmit E-Gripper user instructions v4.0.
Maintenance: regularly clean iron chips and weld spatter from the pole face, and check the friction ring, cable connector and shield earthing; log switching cycles (Magswitch E series can read the number of full-power grips over CANopen). Where workpieces must be non-magnetic, add a demagnetising step downstream.
When residual magnetism in workpieces affects later machining or assembly, treat them with a demagnetiserIndustrial demagnetizer →
08Common design mistakes
Taking maximum force as working load. Magswitch states clearly that maximum force is not a safe lifting force; HGE-SQ-070 has a maximum pull-off force of 900 N, while the working load table gives only 33 kg under the best conditions.
Ignoring air gap. Primer, plating, protective film and scale all cut force several times over; the 0.25 to 0.5 mm cells in the table are often only a quarter of the <0.1 mm ones.
Choosing a big gripper for thin plate. 1 mm plate saturates, HGE-SQ-052 gives only 3 kg at ≥1 mm, and a larger size cannot make it up; add grippers and spread the support points.
Calculating vertical holding with pull-off force. With a vertical pole face, shear capacity must be checked for the actual contact conditions.
Assuming holding at power-off means no interlocks are needed. It also does not release at power-off, so emergency stop, maintenance and fault recovery procedures must consider that "the workpiece stays gripped".
Sizing the supply for average current only. Switching peaks can reach several amperes, and several units switching together cause voltage drop alarms.
Gripping austenitic stainless steel. AISI 304 gives only 1 to 3%, AISI 316 gives 0.
Moving suspended loads over people. Isolate the lifting path and keep people away from suspended loads and possible drop zones. Follow the applicable standards and lifting device instructions for lifting applications.
09Related standards and maker series
Standards cited in the documents
Standard
Subject
Source
EN 13155
Cranes – non-fixed load lifting attachments; magnetic lifters take their safety factor from it
Goudsmit E-Gripper user instructions (safety factor 3); Walmag catalogue
IEC/EN 61000-6-4
Electromagnetic compatibility, emission standard for industrial environments
Goudsmit declaration of conformity
2014/30/EU, 2011/65/EU
EMC Directive, RoHS Directive
Goudsmit declaration of conformity
Use the current edition.
Goudsmit Magnetics: HGE-SQ electro-permanent grippers (also pneumatic magnetic grippers and MagVacu combined magnetic-vacuum grippers).
SCHUNK: EMH electro-permanent grippers with stepwise adjustable force.
SCHUNK EMH-RP 045-B product page ↗Technical data: holding force 1360 N, pole area 10.75 cm², horizontal / vertical payload 22.5 / 9.0 kg, temperature rise, actuation time 300 ms, 24 V, 3.8 A, IP52, outline and weight; gripping and releasing by current pulse
Magswitch, ELAY30x5 Spec Sheet (P/N 81401338, 1101464 r06) ↗Page 1 maximum force versus plate thickness table, SAE 1018/63 µin conditions, SWL = maximum force / safety factor (3:1 recommended), outline and interface; page 3 current, environment, LED status; page 5 Magnet Position 0–100%
Walmag, Catalogue 2026 EN ↗Page 10 Neo EP electro-permanent lifting magnets (safety factor 3:1, pulse switching, 100% duty, maximum 80 °C, outline dimensions); Mastermill / Grindmaster electro-permanent chuck descriptions
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-25
ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN
Buying and using: calculators, sellers, uses
The notes below cover the “Robots, grippers & rotary tables” category. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.
TOOLS / CALCULATE
Related selection calculators
Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.
The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. Price comparison and ranking are not available yet.
SMCPneumatic actuators, controls, vacuum and fluid-control components.
Picking and placing ferromagnetic sheet or workpieces, and as a magnetic chuck for clamping.
Cam-indexed rotary tableSchematic, not to scaleArrow: Electric gripperThis part family has no single typical position; the closest common placement is shown.
Flexible handling of workpieces in several sizesForce-controlled handling of fragile partsIndexing and turning through arbitrary anglesCollaborative robot end tooling