Manufacturer illustration · Monster BoltsPictured model: Phillips pan head Type A self-tapping screw, 18-8 stainlessOriginal source
01 / INTRODUCTION
What is it?
A screw that forms or cuts its own internal thread in an unthreaded pilot hole as it is driven, so a separate tapping operation is not needed.
02 / CONSTRUCTION
Construction & recognition
The thread is hard and the profile is sharp, and the point is tapered or provided with cutting slots or a drill point. Types are classed as thread-forming and thread-cutting, and a drill-point type can also drill its own hole in sheet metal.
03 / APPLICATIONS
Common applications
Sheet metal covers, plastic parts, electrical panels and profile accessories, in positions that are not taken apart often.
Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
A screw that forms or cuts its own internal thread in a plain hole as it is driven, so the tapping operation is dropped. The common national standard self-tapping screw uses the ST thread (GB/T 5280), is case hardened, and has a surface hardness of at least 45 HRC; it suits sheet metal, plastics and non-ferrous parts about 1.2 to 5.1 mm thick. The pilot hole diameter is the critical design value: the standard only says it must be fixed by process trials, so take the screw maker's recommended value or settle the hole by test fitting in the actual material, and leave room for the engagement depth and for the power driver.
01Construction and how it works
The thread of a self-tapping screw has a sharp profile and a coarse pitch, and the screw is case hardened, so it is far harder than the parts it joins. Driven into a pilot hole smaller than the thread major diameter, the thread presses or cuts the hole wall into an internal thread while the screw tightens. The Mechanical Design Manual puts it this way: while the thread is being tapped and the screw tightened in one operation, screw and hole form an interference fit joint, which is simpler and more efficient; the joint is used where strength requirements are modest, the parts may be low carbon steel, plastics, non-ferrous products or hard wood, a pilot hole is normally drilled first, and a self-drilling screw with a drill point needs no pilot hole.
Two forming methods divide the family: thread forming (the material is displaced and flows into the internal thread, with no chips) and thread cutting (the point carries cutting slots and cuts the thread like a tap, producing chips). Which one to use depends on the material of the part and on the screw maker's recommendation. The manual also lists the self-tapping locking screw (shank to GB/T 6559): the thread has a curved triangular section and a hardened surface, it is driven into a metal pilot hole and forms an ordinary thread by displacement, the formed internal thread is more than 30% stronger than a cut one, the minimum tensile strength of the screw is 800 MPa, and the tightening torque needed is small while the locking performance is good.
02Types and designation systems
Common self-tapping screw types
Type
Standard
Features and use
Cross recessed pan head self-tapping screw
GB/T 845
Most common; the head stands proud of the panel
Cross recessed countersunk head self-tapping screw
GB/T 846
Head sinks into a conical hole, surface flush
Cross recessed raised countersunk head self-tapping screw
GB/T 847
Countersunk head with a domed top, neater appearance
Hex head self-tapping screw
GB/T 5285
Turned with a wrench or socket, so a higher torque can be applied
Self-tapping locking screw
GB/T 6561, GB/T 6563 and others, shank to GB/T 6559
Metric general purpose thread (M sizes), thread forming, interchangeable with ordinary screws
Self-drilling screw
—
Drill point at the tip, no pilot hole needed in thin steel sheet
From table 6-1-56 (printed page 6-60) and the screw type table in section 3.7.4 of part 6, chapter 1 of the Mechanical Design Manual, and tables 6-1-122 to 6-1-124 (printed pages 6-111 and 6-123 to 6-125). The standards cited by the manual are the 1985 to 2002 editions; current editions apply.
Point type: the C type has a cone point and the F type a flat point (both appear in GB/T 845 to 847 and GB/T 5285). A cone point finds the hole easily and leads the screw in; a flat point is used in blind holes or where space behind the panel is tight, and its incomplete thread at the end is short. Size is written as ST plus the nominal thread outside diameter, such as ST3.5 or ST4.2; ST2.2 to ST9.5 are common. Cross recesses come in H and Z types.
Laying out a self-tapping screw settles four things: pilot hole diameter, part thickness or engagement depth, head room (pan head height, countersink), and axial room for the power driver or wrench. The dimensions in this section come from the national standards; no maker dimension drawing could be cited directly, so no figure is given.
Head dimensions of cross recessed pan head and hex head self-tapping screws (GB/T 845, GB/T 5285, mm)
Thread size
Pan head dk max
Pan head k max
Hex across flats s max
Hex head height k max
Cone point length y (C type, reference)
Flat point length y (F type, reference)
Commercial length l
ST2.2
4
1.6
3.2
1.6
2
1.6
4.5~16
ST2.9
5.6
2.4
5
2.3
2.6
2.1
6.5~19
ST3.5
7
2.6
5.5
2.6
3.2
2.5
9.5~25
ST4.2
8
3.1
7
3
3.7
2.8
9.5~32
ST4.8
9.5
3.7
8
3.8
4.3
3.2
9.5~38
ST5.5
11
4
8
4.1
5
3.6
13~38
ST6.3
12
4.6
10
4.7
6
3.6
13~38
ST8
16
6
13
6
7.5
4.2
16~50
From table 6-1-122 (GB/T 845-1985, printed page 6-123) and table 6-1-123 (GB/T 5285-1985, printed page 6-124), part 6, chapter 1 of the Mechanical Design Manual; the commercial lengths are for the pan head type. y is the reference length of the incomplete thread at the point, and the engagement depth must deduct it. The length series is 4.5, 6.5, 9.5, 13, 16, 19, 22, 25, 32, 38, 45 and 50.
Head dimensions of countersunk head self-tapping screws (GB/T 846, GB/T 847, mm)
Thread size
ST2.9
ST3.5
ST4.2
ST4.8
ST5.5
ST6.3
ST8
Head diameter dk max
5.5
7.3
8.4
9.3
10.3
11.3
15.8
Head height k max
1.7
2.35
2.6
2.8
3
3.15
4.65
Raised countersunk dome height f approx.
0.7
0.8
1
1.2
1.3
1.4
2
From the continuation of table 6-1-122 in the Mechanical Design Manual (printed page 6-124).
Pilot hole: the national standard states that a self-tapping screw needs a pilot hole before fitting, and that the best pilot hole size should be established by suitable process trials under the actual conditions. The hole diameter depends on the material, the sheet thickness and the forming method: start from the recommended table of the screw maker in use, then settle it by test fitting in the actual material (watching driving torque, stripping torque and pull-out force), with the catalogue as the reference.
Sheet thickness: the national standard gives 1.2 to 5.1 mm as the sheet thickness for self-tapping screws. On thinner sheet the thread engagement is short, so consider an extruded hole, a blind rivet nut or a self-clinching nut; on thicker parts the driving torque becomes large.
Boss on a plastic part: the boss outside diameter, hole diameter and depth come from the screw maker's recommendation (for example the EJOT DELTA PT design guide); no general values are given here.
Driver room: leave room on the screw axis for the power driver (or socket) plus the overall screw length; for a hex head allow for the socket outside diameter.
Mechanical properties of case hardened steel self-tapping screws (GB/T 3098.5)
Thread size
Thread major diameter mm
Minimum breaking torque N·m
ST2.2
2.24
0.45
ST2.9
2.90
1.5
ST3.5
3.53
2.7
ST3.9
3.91
3.4
ST4.2
4.22
4.4
ST4.8
4.80
6.3
ST5.5
5.46
10.0
ST6.3
6.25
13.6
ST8
8.00
30.5
From table 6-1-77 (taken from GB/T 3098.5-2000, printed page 6-80; current editions apply), part 6, chapter 1 of the Mechanical Design Manual. The same table specifies a surface hardness of not less than 450 HV0.3 and a core hardness of 270 to 390 HV; the case depth is graded by size, 0.04 to 0.10 mm for ST2.2 to ST2.6 and 0.15 to 0.28 mm for ST6.3 to ST8. The handbook table was produced by scanning, so check the values against the standard text.
The minimum breaking torque is the lower limit at which the screw itself twists off. In assembly the driving torque must sit clearly below it and also below the stripping torque of the part, and test fitting establishes the window between the two. The torque setting of the power driver is chosen inside that window.
Parameters to state when specifying
Parameter
Notes
Standard and head type
GB/T 845 pan head, GB/T 846 countersunk head, GB/T 5285 hex head and so on
Thread size × length
For example ST3.5 × 16
Point type
C type cone point or F type flat point
Recess
Cross recess H or Z type
Finish
Zinc plated and passivated, for example
Pilot hole diameter
Fixed by test fitting or the maker's recommendation, and written on the part drawing
Designation example (handbook table 6-1-122): self-tapping screw GB/T 845 ST3.5×16, that is a C type cross recessed pan head self-tapping screw of size ST3.5, length 16 mm, H type recess, zinc plated and passivated.
05Selection and calculation
Decide whether a self-tapping screw fitsIt suits joints of modest strength that are rarely taken apart. Where repeated dismantling is needed, the formed internal thread loosens with each cycle, so use a blind rivet nut, a self-clinching nut or a wire thread insert.
Choose the type by the part materialUse ST self-tapping screws or self-tapping locking screws on steel and aluminium sheet; use a self-drilling screw where drilling thin steel sheet is awkward; on plastic parts use a screw the maker designs for plastics and build the boss to that maker's design guide.
Choose the size and lengthPick the size from the load and the sheet thickness; the length must leave enough engagement after the point length y is deducted, and must not reach parts behind the panel.
Fix the pilot holeStart from the maker's recommended diameter, test fit in the actual material and thickness, measure driving and stripping torque, then fix the hole diameter and the driver torque.
Fix the head typeUse a countersunk head where the surface must be flush (the sheet must be thick enough to contain the countersink), a pan head for general work and a hex head where the torque is high.
A self-tapping screw joint has no general calculation formula. Its load capacity depends on the hole diameter, sheet thickness, material and forming method, so it must be taken from the screw maker's test data or from the user's own test fittings.
06Installation and use
Drive it square: the screw axis must line up with the hole; driving at an angle pushes the hole off centre and leaves the thread only partly engaged.
Control the torque: use a clutch driver set between the driving torque and the stripping torque; for plastic parts the driving speed also comes from the maker's advice or from test fitting.
Repeated assembly: when refitting, let the screw follow the existing thread (turn it back to find the thread, then drive it in); otherwise it cuts a new thread and ruins the old one.
Chips from the cutting type: in electrical cabinets and clean equipment allow for chips falling, and prefer the forming type.
07Failure modes and maintenance
Common failures, causes and actions
Symptom
Main cause
Action
Thread stripped
Pilot hole too large, sheet too thin, torque too high
Reduce the hole diameter or the torque as the test fitting shows; on thin sheet change to an extruded hole or a blind rivet nut
Screw twisted off
Pilot hole too small, material too hard, hole too shallow
Open the hole; check against the minimum breaking torque
Plastic boss cracked
Hole too small, boss wall too thin, screw driven too fast
Follow the maker's boss design guide; reduce the speed
Will not hold after a few cycles
The internal thread is cut and worn again and again
Change to a blind rivet nut, a self-clinching nut or a wire thread insert
Cross recess cam-out
Wrong bit type (H and Z mixed) or a worn bit
Match the bit to the recess and replace worn bits
08Common design mistakes
Leaving the pilot hole diameter off the drawing. The hole diameter governs the quality of the joint, so put it on the part drawing and confirm it by test fitting.
Using a tapping drill table for ordinary threads. A self-tapping screw has the ST thread, with a different profile and pitch, so a tapping drill table does not apply.
Self-tapping screws on an access cover that comes off often. After a few cycles they no longer hold; use a self-clinching nut or a blind rivet nut with a machine screw.
Sheet too thin or too thick. The national standard covers 1.2 to 5.1 mm; outside that range find another solution or run tests.
Sizing the length by sheet thickness alone. The point length y must also be deducted, and check whether the screw tip reaches cables or components behind.
09Standards and manufacturer ranges
Related standards
Standard
Subject
GB/T 5280
Thread for self-tapping screws
GB/T 3098.5
Mechanical properties of fasteners, self-tapping screws
GB/T 845, GB/T 846, GB/T 847
Cross recessed pan head, countersunk head and raised countersunk head self-tapping screws
GB/T 5285
Hex head self-tapping screws
GB/T 6559
Shank of self-tapping locking screws, coarse ordinary thread series
Numbers from part 6, chapter 1 of the Mechanical Design Manual (the handbook cites the 1985 to 2002 editions; current editions apply).
Self-tapping screws for plastics mostly use a maker's patented thread, for example the EJOT PT and DELTA PT; hole diameter and boss follow each maker's design guide and cannot be interchanged.
No maker publication with dimensions and drawings could be cited directly for this article, so all values come from the national standards and the handbook.
—Sources
Mechanical Design Manual, part 6 Connections and fastening, chapter 1 Threads and threaded connectionsTable 6-1-56 basic types of threaded joint (self-tapping screw joint, self-tapping locking screw joint, printed page 6-60); section 3.6 table 6-1-77 mechanical properties of self-tapping screws (GB/T 3098.5-2000); section 3.7.4 table 6-1-122 cross recessed pan head, countersunk head and raised countersunk head self-tapping screws (GB/T 845 to 847-1985, printed pages 6-123 to 6-124) with notes 2 to 5; table 6-1-123 hex head self-tapping screws (GB/T 5285-1985, printed page 6-124)
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-20
ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN
Buying and using: calculators, sellers, uses
The notes below cover the “Screws & bolts” category. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.
TOOLS / CALCULATE
Related selection calculators
Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.
The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. Price comparison and ranking are not available yet.
MISUMIFactory automation and tooling components with selection and CAD resources.