Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
An engineering plastic hinge is common on equipment guard doors and viewing windows. The maker gives maximum working loads in three directions: axial, radial and at 90° door opening. Use the door weight, door width, hinge count and hinge spacing to check three conditions, then select the model and quantity. Where the opening must be limited, choose a model with a detent angle. Interlocked doors can use a hinge with a built-in safety switch.
01Construction and how it works
An industrial plastic hinge has two molded hinge bodies and one pin. One body mounts on the frame and the other on the door. The weight of the door presses down along the pin, giving the axial force. The centre of gravity of the door lies some distance from the pin, so the upper and lower hinges balance the moment by pushing and pulling; this is the radial force. When the door opens to 90°, the moment changes direction and the hinge takes the force at 90°. Elesa+Ganter gives the load for each of these three directions for every model.
Hinge body materials (Elesa+Ganter notes)
Material
Features
High rebound elastomer based engineering plastic
Flexible
Glass fibre reinforced polyamide (PA) or polyacetal based engineering plastic
Most common; for example CFA-F uses high rebound PA, with a pin of AISI 303 stainless steel
High rigidity SUPER engineering plastic
Barely deforms up to near failure; only the ultimate static load is given
From Elesa+Ganter, Guidelines for the correct application of plastic hinges, and the CFA-F documentation. For metal hinges in zinc alloy or stainless steel, look up the maker's metal hinge load table.
Three test load directions for Elesa+Ganter plastic hinges. Axial Stress: loaded along the pin, corresponding to the maximum working load Ea. Radial Stress: pulled perpendicular to the pin in the plane of the hinge, corresponding to Er. 90° Angled Stress: load with the door open at 90°, corresponding to E90.Source: Elesa+Ganter, Guidelines for the correct application of plastic hinges
02Types and designation systems
Mounting forms and functional types (Elesa+Ganter example)
Form
Description
Application
-B: threaded insert
A nickel plated brass threaded sleeve, such as M6, is molded into the hinge body, and the screw enters from the back of the panel
Sheet metal doors, panels with screw access from the back
-CH: cap screw through hole
Through hole plus countersink; a socket head cap screw passes through into a T-nut or tapped hole
Profile frames, front mounting on the door panel
-SH: countersunk screw through hole
Countersunk screw gives a flat surface
Where a flat appearance is required
-p: with stud
The hinge body carries an externally threaded stud with a nut behind
Thin panels with nut access from the back
Detent angle type (CFA-F)
Detent at 95°; maximum rotation 105° (-10°~+95°). The detent teeth are inside the hinge and cannot catch the hand
Where the door must not open beyond a set angle
Built-in safety switch type (CFSQ, CFSW)
A safety switch is built into the hinge. It is a safety device, and its load is stated separately in the product documentation
Interlocked guard doors
From the Elesa+Ganter CFA-F documentation and the hinge guidelines. The CFN and CFO series have no E90 value because of their construction. Other functional types, such as removable and damped hinges, are offered by all makers; follow the catalogue for their data.
Maximum working loads Ea, Er, E90: below these loads any elastic deformation will not remain, so the hinge keeps its function. Use them for selection.
Breaking loads Ra, Rr, R90: above them the plastic may break. They indicate only the safety margin and must not be used for selection.
Ultimate static loads Sa, Sr, S90: for SUPER engineering plastic only this value is given. The maker requires the designer to choose a safety factor from the importance and safety class of the application.
Test conditions: 23 °C and 50% relative humidity, measured over a limited time under the stated service conditions. Where the actual temperature, humidity or long term loading differs, allow for this separately.
Recommended tightening torque: for example 2 N·m for the CFA.49-F-CH-5, 3 N·m for the CFA.65-F-CH-6 and 5 N·m for the version with an M6 threaded insert. Do not exceed these.
Test loads of the CFD series hinges (Elesa+Ganter example, N)
Model
Ea
Ra
Er
Rr
E90
R90
CFD.30 B-M3
60
690
70
490
60
500
CFD.40 B-M4
160
1710
150
1340
100
700
CFD.48 B-M5
260
2440
260
1700
120
1640
CFD.48 CH-5-B-M5
330
2530
240
1890
290
1870
CFD.66 B-M6
450
4130
320
2520
220
2250
CFD.66 CH-6-B-M6
430
3660
410
2610
310
2830
From the CFD series table on page 2 of Elesa+Ganter, Guidelines for the correct application of plastic hinges; only some models are quoted. E is the maximum working load and R the breaking load. At the same size, the load also differs with the mounting form.
Test loads of the CFA-F detent hinges (Elesa+Ganter example, N)
Model
Ea
Ra
Er
Rr
E90
R90
CFA.49-F-CH-5
380
3600
370
3300
320
2490
CFA.49-F-SH-5
300
2960
310
2880
320
2490
CFA.65-F-CH-6
810
5410
1000
6550
720
3980
CFA.65-F-SH-6
840
5680
1010
7010
790
3960
CFA.65-F-B-M6
1150
5780
1550
7780
760
3820
From Elesa+Ganter, CFA-F Hinges with detent position at 95° (edition dated 2025-10).
04Selection and calculation
Elesa+Ganter gives a check method for doors with a vertical hinge axis. First work out the weight of the door and of the parts attached to it, such as the handle, lock and control panel. Then select the model and quantity by the three conditions below. All three conditions must be met.
Load check for a door with a vertical hinge axis. Frame and Door are labelled in the figure. P is the weight of the door, acting at its centre of gravity at distance D from the axis, usually D = W/2. P1 is the additional load from the handle, lock, control panel and so on, at distance D1 from the axis. W is the door width. Hinge of reference is the datum hinge, the lowest one, and d1, d2...dn are the distances from the other hinges to the datum hinge.Source: Elesa+Ganter, Guidelines for the correct application of plastic hinges
(P + P1) / N ≤ Ea
P
Weight of the door, N
P1
Weight of the parts attached to the door, N
N
Number of hinges
Ea
Axial maximum working load of one hinge, N
First expression, axial, of the LOAD SUITABILITY CHECK in Elesa+Ganter, Guidelines for the correct application of plastic hinges.
Distance from the door centre of gravity to the axis, m, usually W/2
D1
Distance from the additional load point to the axis, m
dT
Sum of the distances from each hinge to the datum hinge, m (dT = d1 + d2 + ... + dn; with only two hinges it is the spacing between them)
Er, E90
Radial and 90° maximum working loads of one hinge, N; Er with the door closed, E90 with the door open at 90°
Same as the second and third expressions above. The first expression applies with the door closed and the second with the door open at 90°.
Adding hinges only reduces the axial force, since it divides by N. Increasing the hinge spacing is what reduces the radial and 90° forces. On a tall door, put the two hinges as close as possible to the top and bottom.
Parts far from the axis, such as handles and locks on the free edge, give a large D1 and a large effect on the radial force.
The table values are working loads. Leave extra margin where there is impact, people leaning on the door or frequent hard use.
05Installation, adjustment and use
Do not oversize the mounting holes: Elesa+Ganter requires the hole in the frame to be no more than the screw diameter + 0.5 mm. The smaller the clearance the better, or the door will sag and go out of alignment.
Do not exceed the recommended torque in the catalogue, such as 2 to 3 N·m for the CFA-F through hole type or 5 N·m for the M6 threaded insert type. The plastic hinge body will be crushed.
Profile door: use the CH type with through holes. The screws run into T-nuts in the profile slot, so the vertical position can be adjusted along the slot. The MISUMI Q&A notes that a profile frame door is built from 20 or 30 series profiles with a cover panel.
Sheet metal and resin panel doors: use the B type with threaded inserts or the p type with studs, fitting the screw or nut from the back of the panel.
Hinges on one door must be coaxial: fit the frame side first, then hang the door and adjust the door side, and finally tighten each hinge in turn.
Opening angle: the CFA-F reaches at most 105° (-10° to +95°), with a detent at 95°. For other models follow the catalogue. Do not let the hinge itself act as a stop and take an impact at full open.
Mounting holes too large; radial load above Er, leaving residual deformation
Hole diameter ≤ screw diameter + 0.5 mm; recheck with the three expressions and increase the hinge spacing
Hinge body cracks
Torque too high; the door strikes the hinge at full open
Use the recommended torque; fit a separate door stop
Door wobbles or deforms at 90°
E90 is too low, and opening is the most critical case
Reselect by E90, or add hinges and increase the spacing
Softens in a hot environment
Plastic properties fall as temperature rises
Follow the temperature range in the catalogue; compare the actual temperature with the 23 °C test condition
Compiled from the Elesa+Ganter hinge guidelines.
07Common design mistakes
Selecting by the breaking load: the R values in the catalogue are breaking values, several times the working load E, about 6 to 14 times in the CFD table above. Select by E.
Counting only the door weight, not the handle, lock and control panel on the door. These sit on the free edge, where the lever arm is largest.
Two hinges close together: dT is small and the radial force rises sharply.
Checking only the closed door: E90 at 90° open is often the smallest value and must also be checked.
Large clearance holes in the frame: the door sags as soon as it is fitted.
An interlocked door may use an ordinary hinge plus a separate switch. However, a hinge with a built-in safety switch is a safety device and must be selected to the safety circuit requirements. It is not a drop-in replacement for an ordinary hinge.
08Standards and manufacturer ranges
There is no general national standard for plastic hinges. Loads follow the maker's test values.
Elesa+Ganter: CFD, CFA, CFA-F with 95° detent, CFM, CFN and CFO plastic hinges, CFSQ and CFSW hinges with built-in safety switches, plus a metal hinge load table.
MISUMI, Southco and others also offer resin hinges and hinges for profile doors. Follow each maker's catalogue for loads.
—Sources
Elesa+Ganter, Guidelines for the correct application of plastic hinges ↗Pages 1~2 (catalogue pages 1368~1369): materials, definitions of Ea/Er/E90 and Ra/Rr/R90, test conditions, the three expressions and worked example for a door with a vertical axis, mounting hole clearance, and the CFD series load table
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-17
ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN
Buying and using: calculators, sellers, uses
The notes below cover the “Door hardware” category. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.
TOOLS / CALCULATE
Related selection calculators
Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.
The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. Price comparison and ranking are not available yet.
MISUMIFactory automation and tooling components with selection and CAD resources.