How to calculate cylindrical gear pitch diameters and center distance
Use the module and tooth counts to check the pitch diameters and theoretical center distance before taking the design to a strength check. This calculator covers unshifted external spur and helical gear pairs on parallel shafts.
Pitch diameters and theoretical center distance
d₁ = mₙ × z₁ / cosβ, d₂ = mₙ × z₂ / cosβ, a = (d₁ + d₂) / 2, i = z₂ / z₁
mₙ is the normal module in mm. z₁ and z₂ are the pinion and gear tooth counts, and β is the helix angle. Set β to 0° for spur gears. The reference pitch diameter then equals the module times the tooth count.
Match the normal module and normal pressure angle of both gears. External helical gears on parallel shafts use equal helix-angle magnitudes and opposite hands. The result is the theoretical center distance for an unshifted pair.
Worked example for a standard 20-tooth and 40-tooth spur pair
Enter a normal module of 2 mm, 20 pinion teeth, 40 gear teeth, a helix angle of 0°, and a normal pressure angle of 20°. The pitch diameters are 40 mm and 80 mm. The center distance is 60 mm and the gear ratio is 2.
Check integer tooth counts from a target center distance and ratio
Z = 2a / m, z₁ = Z / (1 + i), z₂ = Z − z₁
Use this reverse check for an unshifted external spur pair at the chosen module. With a = 60 mm, m = 2 mm, and i = 2, the total tooth count Z is 60. This gives 20 pinion teeth and 40 gear teeth.
Both tooth counts must be positive integers. Check the calculator's undercut message. If either result is fractional, use the permitted center-distance and ratio deviations to compare integer candidates, then enter those candidates in the calculator.
Check strength at the actual operating conditions
For a preliminary check of a standard external steel gear pair at a 20° normal pressure angle, gather the transmitted power, pinion speed, face width, and load factor. Use the material, heat treatment, and required service life to choose permissible contact and bending stresses. Account for impact and frequent load reversals when assessing the duty.