A vacuum pump with no oil or sealing fluid in the pumping chamber; common types include screw, claw, Roots and scroll, and this entry takes the widely used screw type as its example.
02 / CONSTRUCTION
Construction & recognition
Timing gears keep the two rotors in phase and out of contact; together with the housing they form sealed threads that carry gas stage by stage to the outlet. There are no inlet or discharge valves; variable pitch provides internal compression to limit pulsing and heating. Rotor-to-housing clearance sets ultimate pressure, and compression heat is removed by water or air cooling.
03 / APPLICATIONS
Common applications
Semiconductor and coating, chemical and pharmaceutical processes, freeze drying and leak testing, where clean vacuum and no oil backstreaming are required.
Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
A vacuum pump that uses no oil or liquid seal in the compression chamber. Claw and screw types are common in industry. Scroll types are widely used in laboratories and as backing pumps for high vacuum. Selection looks at ultimate pressure and the whole pumping speed curve. Calculate the effective pumping speed from the target pressure and the pump-down time. Then compare with oil-sealed pumps on oil backstreaming, medium compatibility and maintenance.
01Construction and how it works
Dry means there is no sealing oil or working fluid in the pump chamber. Leybold's Fundamentals of Vacuum Technology, called the Fundamentals below, groups claw, Roots and scroll pumps as dry compression vacuum pumps (table 2.1). Take the claw type as an example. The chamber section is two partially overlapping circles. Each stage has two claw rotors turning in opposite directions, synchronised by gears. The rotors do not touch each other or the housing, and the clearance is only a few hundredths of a millimetre. The rotors open and close the inlet and exhaust slots in turn, giving intake, compression and exhaust (Fundamentals, 2.1.3.2). In a screw pump, two helical rotors turn in opposite directions and gas is trapped in the tooth spaces and pushed to the exhaust end. A scroll pump works on the same principle as a scroll compressor.
Heat generation: in section 2.1.3.2, the Fundamentals notes that nearly all compression work becomes heat. Under vacuum the gas is thin, so heat does not pass easily to the housing. The gas inside a dry pump therefore runs hot. In a claw pump the rotors are the hottest part. A multistage claw pump needs water cooling to remove the compression heat.
Where the oil is: the pump chamber has no oil, but the gearbox and bearings are still lubricated. Piston rings and radial shaft seals separate the gearbox from the pump chamber. When pumping corrosive gas, a purge gas protects the bearings and shaft seals (Fundamentals, section 2.1.3.2.1, DRYVAC example).
Temperature class: the Busch COBRA NC 0600 C catalog states that gas temperature is kept below 200 °C. It is certified to ATEX temperature class T3 and suits temperature-sensitive process gases. It is water cooled.
Catalog page of the Busch MINK MM 0084–0182 A dry claw vacuum pump. Left: Dimensional drawing, with dimension symbols matching the L×W×H values below. Right: Pumping speed curve, Air at 20°C, Tolerance ±10%. Solid lines are 50 Hz and dashed lines 60 Hz. The horizontal axis is inlet pressure and the vertical axis is pumping speed. Four sets of curves correspond to four models. Pumping speed is highest near atmosphere and falls rapidly as the ultimate pressure is approached (40~60 hPa).Source: Busch, MINK MM 0084–0182 A Dry claw vacuum pumps product catalog
For a package unit with several pumps, a tank and controls, see the vacuum pump station. For a local vacuum source driven by compressed air, see the vacuum ejector.Vacuum pump station →Vacuum Ejector →
02Types and designation systems
Vacuum ranges
Range
Pressure range mbar (=hPa)
Common pumps
Rough vacuum
1000 ~ 1
Claw, screw, rotary vane, liquid ring
Medium vacuum
1 ~ 10⁻³
Screw, Roots pump with a backing pump, two-stage rotary vane
High vacuum
10⁻³ ~ 10⁻⁷
Turbomolecular pump, diffusion pump, etc. (need a backing pump)
Ultra-high vacuum
< 10⁻⁷
Ion pump, cryopump, etc.
Ranges from chapter 1 of Leybold, Fundamentals of Vacuum Technology (citing DIN 28400 part 1). The Common pumps column is compiled from the working ranges of each pump type in chapter 2 of that book. The ultimate pressure of the selected model governs in practice. 1 hPa = 1 mbar.
Dry pumps compared with oil-sealed and liquid ring pumps (series examples and general features)
Pump type
Example
Pumping speed
Ultimate pressure
Features
Dry claw
Busch MINK MM 0084~0182 A
62/75 ~ 140/175 m³/h (50/60 Hz)
40~60 hPa
Rough vacuum, air cooled, nearly maintenance free; suits pick and place, packaging and pneumatic conveying
Dry screw
Busch COBRA NC 0600 C
600 m³/h
≤0.01 hPa
Reaches medium vacuum; water cooled; can pump process gas
Dry scroll
Used in the Leybold book as an oil-free backing pump for a turbomolecular pump
Small
Follow the catalog
Oil-free backing for laboratory and analytical instruments
Oil-sealed rotary vane / rotary piston
—
—
Two stages reach medium vacuum
Oil backstreaming; open the gas ballast when pumping condensable vapour; change oil at intervals
Liquid ring pump
—
—
Rough vacuum
Can pump saturated vapour with a little liquid; consumes working fluid
Busch values from the MINK MM 0084–0182 A and COBRA NC 0600 C product catalogs. General features from Leybold, Fundamentals of Vacuum Technology, 2.1.2 (liquid ring and rotary vane pumps, gas ballast) and 2.2.5 (oil-free vacuum).
03Outline, connections and installation space
The outline of a dry vacuum pump is basically a horizontal row of pump head plus motor on a base. Busch is used as the reference. At the same pumping speed rating, length and inlet and outlet positions differ noticeably between brands. When changing brand, recheck against the new outline drawing. Details of the outline drawing follow the catalog.
Outline drawing of the Busch COBRA NC 0600 C dry screw vacuum pump. Left, the side view: L is the overall length including the motor, the vertical downward arrow marks the inlet on top of the pump, and the horizontal arrow at lower left gives the exhaust direction. Right, the end view: W is the width and H the height. The catalog table gives L × W × H = 1502 × 602 × 640 mm. Both inlet and outlet are DN 100 ISO-K flanges.Source: Busch, COBRA NC 0600 C Dry screw vacuum pump product catalog
Outline and connections of Busch dry pumps (series examples)
Model
Pumping speed m³/h
Motor kW
Noise dB(A)
Mass kg
Outline L×W×H mm
Inlet / outlet
MINK MM 0084 A
62 / 75
1.5 / 1.7
66 / 70
155
993 × 416 × 410
G 1¼" / R 1"
MINK MM 0104 A
80 / 95
2.2 / 2.4
66 / 70
155
977 × 416 × 410
G 1¼" / R 1"
MINK MM 0142 A
110 / 135
3.0 / 3.4
75 / 79
150
971 × 416 × 410
G 1¼" / R 1"
MINK MM 0182 A
140 / 175
3.5 / 4.8
75 / 79
160
997 × 416 × 410
G 1¼" / R 1"
COBRA NC 0600 C
600
18.5
≤74 / ≤76
600
1502 × 602 × 640
DN 100 ISO-K / DN 100 ISO-K
From the Busch MINK MM 0084–0182 A and COBRA NC 0600 C product catalogs. Values before and after the slash are for 50 / 60 Hz. Noise is measured to ISO 2151 (COBRA states KpA = 3 dB). MINK motor speeds are 1500/1800 r/min for 0084/0104 and 3000/3600 r/min for 0142/0182. The COBRA runs at 3000/3600 r/min and draws 9 kW at ultimate pressure.
Inlet: threaded ports (G, R) are common on small pumps. Flanged ports follow vacuum flange standards. In China the corresponding standard is GB/T 6070-2007, included in part 10 of the Mechanical Design Handbook. The inlet pipe section must be no smaller than the pump inlet. Increase the bore for long runs (the Busch SIMPLEX manual requirement for system piping).
Outlet: the exhaust pipe must not slope back towards the pump. Fit a liquid separator or a trap with a drain valve to stop condensate flowing back into the pump (Busch SIMPLEX manual).
Cooling: the MINK MM is air cooled, so keep the cooling air inlet and outlet clear. The COBRA NC is water cooled and needs a cooling water connection (connection size follows the catalog).
Electrical: select for 50/60 Hz. Pumping speed and power change with frequency. A pump with a frequency drive has an EMC class requirement (follow the catalog).
Maintenance space: leave room to reach the gearbox for oil changes, the inlet screen for cleaning, and the motor for service. Exact distances follow the manual.
Pumping speed curve of the Busch COBRA NC 0600 C (Pumping speed, Air at 20°C, tolerance ±10%). The horizontal axis is inlet pressure p in hPa (mbar), on a log scale from 0.01 to 1000. The vertical axis is pumping speed V̇ in m³/h. Reading the curve: about 600 m³/h at 10 to 200 hPa, about 550 at 1 hPa, about 450 at 0.1 hPa, and down to zero near the ultimate pressure of 0.01 hPa. Near 1000 hPa (atmosphere) it is about 550.Source: Busch, COBRA NC 0600 C Dry screw vacuum pump product catalog
Parameters to read from the catalog
Parameter
Meaning
How to use it in selection
Nominal pumping speed
Catalog stated value, usually the maximum on the curve
Do not use it directly to calculate pump-down time. Read the speed at the working pressure.
Pumping speed curve
How pumping speed varies with inlet pressure
Read the value over the working pressure range. Near ultimate pressure the speed tends to zero.
Ultimate pressure
Lowest inlet pressure the pump can reach
Working pressure must be several orders of magnitude above ultimate pressure for the expression to hold
For long running at low pressure, calculate energy cost from the actual power draw
Cooling method
Air / water cooled
Decides whether cooling water and ventilation are needed
Noise
ISO 2151; see the notes for distance and measuring conditions
Compare for local installation
Explosion protection and temperature class
Such as ATEX, T3
Must be checked when pumping flammable gas
Inlet and outlet size
Threaded or flanged, such as ISO-K
Sets the pipe and valve sizes
Compiled from the Busch MINK MM and COBRA NC catalogs and section 2.3.1 of Leybold, Fundamentals of Vacuum Technology.
05Selection steps and calculation
Set the working pressure and volumeState the target pressure p, the volume V of the vessel including piping, and the allowed pump-down time t. For continuous pumping, also know the leakage and outgassing rates.
Calculate the required effective pumping speedFor rough vacuum with no extra gas source, use the expression below.
Allow for piping lossesWork back from the effective pumping speed and the conductance of the piping to the pump speed.
Select from the pumping speed curveRead the speed over the range from p to atmosphere. Confirm it is adequate over the whole range and that ultimate pressure is far below p.
Compare dry and oil-sealed typesSee the table below for condensable vapour, dust and corrosiveness in the medium, sensitivity to oil backstreaming, and maintenance conditions.
t = (V / Seff)·ln(1013 / p)
t
Time to pump down from atmosphere (1013 mbar) to p, h
V
Volume of the vessel, m³
Seff
Effective pumping speed at the vessel mouth, m³/h, treated as constant during pump-down
p
Target pressure, mbar
Leybold, Fundamentals of Vacuum Technology, section 2.3.1.1, equations (2.34)~(2.36), printed pages 66~67. It is also written as t = τ·σ, with τ = V/Seff and σ = ln(1013/p). It applies only to rough vacuum with no extra gas source and with the pump ultimate pressure several orders of magnitude below p. A single-stage rotary vane or rotary piston pump with gas ballast loses speed below 10 mbar. Figure 2.75 in the book corrects this with a dashed line.
1/Seff = 1/S + 1/C
Seff
Effective pumping speed at the vessel mouth
S
Pumping speed of the pump itself
C
Total conductance of piping, valves and filters between pump and vessel (same units as pumping speed)
Leybold, Fundamentals of Vacuum Technology, section 1.5, equation (1.24), printed page 15. Only when C is infinite does Seff = S. The pump speed must therefore be larger than the required effective pumping speed. Conductance of valves, cold traps and separators is usually found by test. The speed reduction of a dust filter can be found in the catalog.
Dry pump or oil-sealed pump
Point
Dry pump
Oil-sealed pump (rotary vane / rotary piston)
Oil backstreaming
No oil in the chamber and no oil vapour backflow
Oil backstreaming occurs. Leybold recommends at least a two-stage pump and an adsorption trap in the pumping line where oil-free conditions are needed
Condensable vapour
Gas temperature is high, so condensation is unlikely, but condensate backflow damages the pump
Open the gas ballast valve. Otherwise vapour condenses in the pump and emulsifies the oil
Dust and particles
Rotor clearances are small, so filter dust at the inlet
Oil can trap some particles, but oil degradation is faster
Maintenance
No working oil; only the gearbox oil and the filter screen need attention
Change the oil and the oil mist filter at intervals
Exhaust
Exhaust contains no pump oil
Exhaust carries oil mist and needs an oil mist separator
Price and noise
Generally higher; follow the catalog
Follow the catalog
Compiled from Leybold, Fundamentals of Vacuum Technology, 2.1.2 (gas ballast), 2.2.5 (oil-free vacuum) and 8.3.1 (oil-sealed pump operation). Price and noise vary by model.
Fit a screen or filter at the inlet to keep welding slag and dust out of the pump. Blow new piping clean before connection (Busch SIMPLEX manual).
Jog the pump before starting to check the direction of rotation. Reverse rotation damages the pump quickly (Busch SIMPLEX manual).
Slope the exhaust pipe towards the discharge point or add a separator to stop condensate flowing back.
For a water-cooled pump, start the cooling water before starting the pump. Follow the water temperature and flow in the catalog.
When pumping flammable or toxic gas, select by the explosion protection rating and lead the exhaust to a safe place. Use an inert gas as purge or gas ballast if needed.
For a pump with a frequency drive and frequent starting, use a control signal. Do not switch power on and off repeatedly. The Busch SIMPLEX allows at most 60 power-on starts an hour, with at least 10 s between them.
07Failure modes and maintenance
Common problems, causes and actions
Symptom
Main cause
Action
Cannot reach the expected pressure
Air leak, piping conductance too small, pump worn
Find the leak, enlarge the piping, recheck with the 1/Seff expression
Pump-down time longer than calculated
Calculated from nominal pumping speed; outgassing or vapour present
Calculate from the curve speed in the working range and allow for outgassing
Pump runs hot or seizes
Insufficient cooling; dust or deposits blocking the rotor clearance
Check cooling, add inlet filtration, flush as stated in the manual
Liquid at the exhaust outlet
Exhaust pipe slopes back; condensate returns
Correct the slope; add a separator or drain valve
Gearbox oil degraded
Shaft seal leak; process gas entering
Change the oil; check the shaft seal and purge gas
Compiled from chapter 2 of Leybold, Fundamentals of Vacuum Technology, and the installation and fault chapters of the Busch SIMPLEX manual. Maintenance intervals follow the manual.
08Common design mistakes
Calculating pump-down time from nominal pumping speed. The speed at the working pressure may be only a fraction of the nominal value. Read the curve.
Choosing a pump with the working pressure close to ultimate pressure. Near ultimate pressure the speed tends to zero. The pump never quite arrives.
Ignoring piping conductance. Long narrow pipes, valves and filters can take a large share of the effective pumping speed.
Assuming a dry pump can handle anything. Dust and media that coke or deposit can jam the small-clearance rotors. Filter them or choose a dedicated type.
Letting the exhaust pipe slope back towards the pump. Condensate flows back into the pump chamber.
Using a medium vacuum pump for rough vacuum pick and place. A claw pump already covers 40 to 60 hPa. A screw pump costs much more and uses much more power.
09Standards and manufacturer ranges
Related standards
Standard
Subject
Source
DIN 28400
Vacuum technology, terms and definitions (including vacuum ranges)
Leybold, Fundamentals of Vacuum Technology
DIN 28426
Acceptance rules for rotary piston and rotary vane vacuum pumps, and Roots pumps
Leybold, Fundamentals of Vacuum Technology, chapter 10
PNEUROP 6602
Vacuum pump acceptance rules (oil-sealed rotary pumps and Roots pumps)
Leybold, Fundamentals of Vacuum Technology, chapter 10
ISO 2151
Noise measurement for compressors and vacuum pumps
Busch MINK and COBRA catalogs
GB/T 6070-2007
Vacuum technology, flange dimensions
Mechanical Design Handbook, part 10, chapter 2, section 7
ISO 228-1
Pipe threads (G thread connections)
Busch SIMPLEX manual
Current editions apply.
Busch: MINK dry claw pumps (MM and MV series), COBRA dry screw pumps (NC, NF and DS series).
Leybold: the book describes the DRYVAC multistage dry claw pump in three configurations, B, P and S.
For other brands, follow their own catalogs.
—Sources
Leybold, Fundamentals of Vacuum Technology (English edition) ↗Chapter 1, vacuum ranges (printed page 13). Section 1.5, equation (1.24), effective pumping speed and conductance (printed page 15). Table 2.1, pump classification (printed pages 18~19). Section 2.1.2, liquid sealed pumps and gas ballast. Section 2.1.3.2, claw pumps (printed pages 30~33). Section 2.2.5, oil-free vacuum (printed page 64). Section 2.3.1.1, rough vacuum pump-down time, equations (2.32)~(2.36), with a worked example (printed pages 66~67). Section 8.3.1, oil-sealed pumps. Chapter 10, list of standards.
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-18
Removes gas to reach the required vacuum without using a sealing liquid in the pumping chamber.
Operating principle
In a dry screw pump skid, two synchronized counter-rotating rotors and the housing form chambers that travel from the inlet to the exhaust, conveying and compressing the gas. The skid also integrates the drive, cooling, purge flow and inlet and exhaust handling.
Process sequence
Confirm the gas and cooling requirements
Start in the specified sequence
Draw in the gas
Convey and compress the gas with the screw rotors
Discharge the gas and shut down in a controlled manner
Key inputs
Gas composition and vapor load
Operating vacuum and pumping speed
Cooling, purging and exhaust back pressure
Common issues
If pumping speed falls, check for leaks and deposits inside the pump.
If temperature rises abnormally, check cooling and exhaust restrictions.
Scope and limitations
Dry describes the pumping chamber. The gearbox may still use lubricant.
Dry pumps also include claw and scroll designs.
Functional modules
Dry screw pump
Conveys and compresses the gas being removed.
Timing gears and drive
Keep the rotors in phase.
Cooling and purging
Control temperature and deposits as required by the gas process.
Skid piping and monitoring
Connect to the process and monitor pressure and temperature.