COMPONENT / PLASTIC-CABLE-CARRIER

Plastic Cable Carrier

Plastic Cable Carrier · igus
Manufacturer illustration · igusPictured model: Representative E2 series illustrationOriginal source

Video demonstrations

Footage · 0:10Rotary cable carrier in use: as the inner ring turns, the chain folds back in the outer track and the cables follow
Source: the site owner’s published channel videos · original author not marked on screen · © the original author, quoted for reference; muted
01 / INTRODUCTION

What is it?

An accessory with pivoting links that constrain the bending path of moving cables and hoses.

02 / CONSTRUCTION

Construction & recognition

Links define bending direction and radius; internal separators organize cables. The carrier must not carry the load used to pull the equipment.

03 / APPLICATIONS

Common applications

Cable management on reciprocating slides, motion axes and moving tool heads.

Browse this category

Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.

ENGINEERING GUIDE

Selection and design guide

A plastic cable carrier uses linked reinforced-nylon segments to guide cables and hoses on a reciprocating axis. Choose bend radius and cavity from the cable data, calculate chain length from travel, and check unsupported span for the filled carrier.

01Construction and operating principle

A carrier consists of hinged links with side plates and crossbars or covers. Joint stops limit bending in one plane at a specified radius R. The fixed end attaches to the frame, and the moving end travels with the carriage. The bend moves along the chain between the upper and lower runs, holding the cables to the chosen bend geometry.

The carrier controls the cable bend path. Select a radius above the cables' dynamic requirements and allow the cables to move without rubbing, tangling or pulling on the ends. Cable selection and routing determine how well the installed system lasts.

Geometry of an unsupported cable carrier. MechWiki illustration based on the igus unsupported design guide.
Geometry of an unsupported cable carrier. MechWiki illustration based on the igus unsupported design guide.
Cable carrier components
ComponentFunctionNotes
Side platesCarry weight and tension, and set bend radiusReinforced nylon, commonly −40~+130 °C
Crossbars or coversForm the cavity and retain the cablesOpenable designs ease installation and maintenance.
Separators and shelvesSeparate cables into compartmentsSeparate different cable sizes and cables from air hoses.
BracketsMount fixed and moving endsFixed or pivoting styles
Strain relief (clamps)Restrain cables at the endsMaintains cable length within the moving section.

Based on the igus unsupported design guide and industry reinforced-nylon carrier data.

02Types and size ranges

Configurations by construction and use
  • Open crossbar carrier
    Open crossbar carrier

    Openings between crossbars give ventilation and let operators see the cables. Crossbars can open on the inner or outer side.

    Applications
    Linear modules, gantries and general automation.
    Selection tips
    Set cavity height from the largest cable and width from the cable diameters. Use covers where there are chips or weld spatter.
    JFLO catalog, J30Q.1.S series illustration
  • Enclosed carrier
    Enclosed carrier

    Upper and lower covers enclose the cables against chips, weld spatter, dust and coolant.

    Applications
    Machine tools, welding, cutting and grinding.
    Selection tips
    At equal cavity height it is heavier and ventilates less, and may support a shorter free span. Choose openable covers for service.
    JFLO catalog, J25F.1.S series illustration
  • Long-travel gliding carrier
    Long-travel gliding carrier

    The upper run glides over the lower one or in a guide trough. Rollers reduce sliding friction for heavy long-travel applications.

    Applications
    Gantry, crane and storage equipment with travel from tens to hundreds of meters.
    Selection tips
    Provide a guide trough. Use the manufacturer's gliding length and lowered moving-end height rules and check speed and acceleration.
    igus catalog, P4 roller carrier
  • Low-noise, high-speed carrier
    Low-noise, high-speed carrier

    Short pitch and damped or flexible joints reduce vibration and noise.

    Applications
    Fast reciprocating axes, placement and inspection equipment, and noise-sensitive applications.
    Selection tips
    Check the load and unsupported span. igus E6.29 lists FLB at 1.75 m for a load of 3 kg/m.
    igus E6.1 product page
  • Cleanroom carrier
    Cleanroom carrier

    Low-wear materials or flexible jointless bands limit particle generation.

    Applications
    Semiconductor, display, medical and laboratory equipment.
    Selection tips
    Check cleanroom certification, such as ISO Class 1. Band-style systems have short unsupported spans, about 1 m for e-skin SK28. Add support for longer runs.
    igus catalog, e-skin cleanroom system
  • Three-dimensional robotic carrier
    Three-dimensional robotic carrier

    Round sections flex in several directions and allow torsion, with a retraction system to control slack.

    Applications
    Hose and cable packages on six-axis robot arms.
    Selection tips
    Select for the robot and bundle diameter. Use the manufacturer's torsion and retraction calculations.
    igus triflex R TRC product page
  • Rotary carrier
    Rotary carrier

    Runs in an annular trough and travels through a defined angle in either direction.

    Applications
    Turntables, rotary axes and rotary workstations.
    Selection tips
    Size by angle and guide diameter using the supplier method.
    igus twisterchain product page
  • Steel carrier
    Steel carrier

    Galvanized or stainless side plates and aluminum or steel crossbars or rollers suit high loads, heat, chips and impact.

    Applications
    Heavy machine tools, metalworking and forging.
    Selection tips
    Include carrier weight in the drive load. Protect against corrosion outdoors or in damp areas.
    TSUBAKI KABELSCHLEPP S/SX1802 product page

Product images are credited to JFLO, igus and TSUBAKI KABELSCHLEPP. Types follow manufacturer material and the steel-carrier section in Mechanical Design Handbook Part 21, Chapter 9, Section 4. Rotary and 3D layouts use their own manufacturer length calculations.

03Key parameters

Clearance for cables and hoses inside the carrier
Cable or hoseMinimum allowance relative to ODAdditional guidance
Round cable10%igus shows at least 1~2 mm clearance.
Flat cable10%Provide strain relief at both ends.
Pneumatic hose5%~10%Use 10% for rubber hose.
Hydraulic hose20%Pressure can lengthen and stiffen the hose.
Other media hose15%~20%—

From igus filling rules and industry selection notes. If d1 + d2 ≤ 1.2 times the cavity height, use a separator or shelf to prevent overlap. For similar cables sharing a compartment, keep height within 1.5 times the cable diameter. Above 0.5 m/s and 10,000 cycles per year, stacked cables need a shelf.

Approximate cable bend radius as a multiple of OD
Cable or hose typeMultiple
High-flex carrier cable (imported)About 6~7.5
Domestic carrier cable8~10
Pneumatic or water hose10~12
Hydraulic hoseAbout 12
Steel carrier (handbook)At least 10 times the largest hose or cable diameter

Industry selection notes, MechWiki carrier calculator and the SLE steel-carrier selection guidance in Mechanical Design Handbook Part 21. Use each cable's specified minimum moving bend radius and allow margin above the largest requirement. igus notes that a larger radius extends cable life.

  • Pitch. Small carriers about 20~30 mm. Medium carriers 45~65 mm. Shorter pitch improves smoothness and noise.
  • Speed and acceleration. One reinforced-nylon series lists 5 m/s, 5 m/s² and about 5,000,000 unsupported cycles. igus describes unsupported service life as generally at least 10,000,000 cycles. Ratings depend on the series.
  • Fill mass. ms = total cable mass / length, in kg/m. This value determines usable unsupported span.

04Unsupported span and sag

The upper run is supported by the chain's camber. A heavier fill or longer free span increases sag. Once the upper run touches the lower run, friction can wear out links and cables. Check unsupported span using cable mass after sizing radius and cavity.

Unsupported-length definitions
DesignationMeaningWhen to use
FLG, straight unsupported lengthMaximum span with the upper run essentially straightAccurate positioning, high speed and acceleration, or where movement must stay stable
FLB, unsupported length with permissible sagMaximum free span with some sag and no lower-run contact. Greater than FLG.General applications
Above FLBThe upper run contacts the lower run.Select a stronger series, use a guided gliding system, or add support rollers or a support plate.

FLG and FLB conventions follow igus and JFLO catalogs.

Plot cable mass per meter against required span on the selected series chart. Below the limit curve is usable. With the fixed end centered, the required unsupported span is about half the stroke plus any offset from center. Add the per-meter mass of each cable.

Unsupported-span examples from igus and JFLO catalogs
Manufacturer and seriesInner height, mmPitch, mmCable mass limitUnsupported spanSource
igus E2.1010.1200.7 kg/mFLB ≤ 0.75 migus printed page 42
JFLO J10Q.11015About 0.3 kg/mFlat through 0.7 m, reaches zero near 1.0 mJFLO page 3
igus E3.222216.70.85 kg/mFLB ≤ 1.2 migus printed page 54
igus E2/000 14002133.32 kg/mFLB ≤ 1.75 migus printed page 44
igus E4.212130.54 kg/mFLB ≤ 2.5 migus printed page 48
JFLO J25Q.1.S2546About 6 kg/mFlat through 1.2 m, reaches zero near 2.4 mJFLO page 19
JFLO H30Q.13046About 4 kg/mFlat through 1.2 m, reaches zero near 1.6 mJFLO page 59
JFLO J30Q.1.S3046About 8 kg/mFlat through 1.4 m, reaches zero near 2.4 mJFLO page 29
igus E2/000 260035568 kg/mFLB ≤ 2.75 migus printed page 44
igus E4.32325615 kg/mFLB ≤ 3.3 migus printed page 48
igus E4.56568462.5 kg/mFLB ≤ 5 migus printed page 48
JFLO J60Q.1.S6091About 32 kg/mFlat through 1.5 m, reaches zero near 3.5 mJFLO page 45

The igus data are FLB values from the catalog overview. JFLO data are approximate chart readings. A similar cavity height can yield more than a twofold difference in span. Heavier fill reduces span. Filter by cable mass in the cable carrier tab of the wiring tool.

Use the wiring tool to filter carrier series by cable mass. Reuse the cables from the duct fill tab.

05Selection and calculations

  1. List the cables and hosesRecord OD, minimum dynamic bend radius and mass per meter for each cable and hose.
  2. Choose bend radiusTake the largest cable requirement and round up to an available R.
  3. Size internal height and widthAdd clearance to the largest diameter for height and to the side-by-side sum and separators for width.
  4. Locate the fixed end and calculate lengthCenter it in the stroke for the shortest chain, or add the offset.
  5. Check installation orientationCheck unsupported span for a horizontal run. Use a gliding guide trough if needed. Hanging, standing and side mounting have separate checks.
  6. Set layout and strain reliefDistribute heavy cables symmetrically near the sides and use suitable end clamps.
R ≥ max(kᵢ · dᵢ), hi ≥ 1.1 · dmax, Bi ≥ 1.1 · Σd + separator thickness
R
Carrier bend radius, mm
kᵢ, dᵢ
Bend factor and outside diameter of each individual cable, mm for dᵢ
dmax
Largest cable outside diameter, mm, used to size the cavity
hi, Bi
Inner height and width of the carrier, mm
Σd
Sum of outside diameters in one row, mm

Use 1.2 for hydraulic hoses. In the industry example, five cables of 20, 30, 15, 20 and 15 mm use factor 1.15 for about 34.5 mm height and 115 mm width.

Lk = S/2 + ΔM + K, K ≈ π · R + 2T
Lk
Chain length, mm, round up to a whole link pitch
S
Travel, mm
ΔM
Fixed-end offset from the center of travel, mm
K
Extra length for the bend, mm. Use the series value or estimate πR plus two pitches.
T
Link pitch, mm

igus formula for straight travel with the fixed end near center. Use other manufacturer methods for rotary and most long gliding runs. For steel carriers, the Mechanical Design Handbook lists L = Ls/2 + πR + R.

H = 2R + HG (allow extra room for camber)
H
Installation height, mm
HG
Link outside height, mm

igus carriers can have factory camber that straightens when filled. Leave room above the unloaded run. Industry guidance suggests H = 2R + 1.2·HG.

Calculate bend radius, cavity, length, link count and sag in the wiring tool. Reuse cables entered on the duct fill tab.

06Installation, adjustment and operation

Three unsupported states
StateDefinitionImplication
Straight upper run (FLG)Sag at most half a link heightPreferred operating state
Permissible sag (FLB)Sag smaller than the carrier's minimum bend radiusUsable with speed and acceleration limits
Critical sagUpper run noticeably sags toward the lower runMajor reduction of life, speed and acceleration

igus unsupported design guide. For long spans, use a guide trough for gliding operation or add carrier support.

  • Strain relief. Secure round cables at both ends unless the installation guide specifies moving-end-only restraint. For most cables, igus cites a distance of 10~30 cable diameters from bend to clamp.
  • Unreel without twist. Rotate the reel and lay cables straight before installation.
  • Balance the fill mass. Keep heavy lines toward the outer plates and light ones near the middle.
  • Allow each cable to move. No ties inside the moving portion. Only use end restraints as specified.
  • Guide long gliding runs. The upper run slides on the lower run in a trough. Some systems reverse about three links near the moving end. Follow the chosen series instructions.

07Failure modes and maintenance

Common failures and remedies
SymptomCauseRemedy
Broken conductors or jacket wearRadius too small, unsuitable ordinary cable or crowded fillIncrease R, use continuous-flex cable and restore clearance.
Cable pulls out or bunchesMissing strain relief or internal tiesUse end restraint and leave the moving length free.
Upper run rubs on lower runExcess unsupported span or fill weightUse a higher capacity carrier or a guided gliding layout.
Cracked side plates or worn pin holesImpact, lateral load, speed or temperature outside limitsAdd guidance and follow speed and temperature limits. Change material or consider steel.
Carrier tips sidewaysNarrow carrier with a large radius or unsupported vertical standing installationUse a wider carrier, add guides, or reduce R only within all cable limits.
Crossbars pop offFill pushes covers outwardChoose a larger cavity.

Based on component reference notes, igus documentation and common selection and maintenance practice.

Inspect links for whitening or cracks, the upper run for increasing sag and cable jackets for wear at the bend. Replace damaged links as permitted by the manufacturer. Investigate routing and clearance before replacing a worn cable.

08Common design mistakes

  • Using the carrier radius alone. A carrier rated for R38 can still damage a cable that cannot accept R38.
  • Overfilling or stacking. Pressurized hoses can stiffen and squeeze cables. Use clearances and separators.
  • Tying cables together inside the moving chain. Each cable needs freedom to move under strain.
  • Omitting strain relief. Tension then acts on connectors, which can loosen.
  • Using unsupported installation for excessive spans. Contact between the runs wears links and cables.
  • Using ordinary cable. Repeated flexing can break the conductors. Use continuous-flex cables.
  • Sharing a compartment with pressurized hoses. A stiffened pneumatic or hydraulic hose can press on adjacent cables.

09Standards and manufacturer series

References and scope
SourceScope
Mechanical Design Handbook, Part 21, Chapter 9, Section 4TL and SLE steel-carrier sizes, length calculations and supports
igus e-chain design guidanceLength, fill, unsupported states and strain relief
UL94Material flammability. One industry reinforced-nylon carrier example is rated HB.

Use manufacturer dimensions and ratings for engineering-plastic carriers.

  • igus. E2 series, E6/E6.1 low-vibration high-speed systems and fully enclosed carriers, with chainflex cables.
  • MISUMI and YIHEDA. Order by inner height and width and bend radius, with end brackets.
  • Common domestic plastic carrier designations list inner height, inner width and radius, for example 35.75.100.
Continuous-flex cables, linear modules and servo motors for carrier installations.High-Flex Cable →Electric Linear Module →Ac Servo Motor →

—Sources

Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-20

ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN

Buying and using: calculators, sellers, uses

The notes below are specific to this entry. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.

TOOLS / CALCULATE

Related selection calculators

Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.

07 / SELLERS

Who sells it

The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. This entry also lists well-known makers; those outside the site directory are linked only when the official site was checked. Price comparison and ranking are not available yet.

08 / WHERE IT IS USED

Typical uses & where it sits in machines

Cable management on reciprocating slides, motion axes and moving tool heads.

BaseLinear guide & blocksRail clampServo motorMotor bracketCouplingFixed-end supportBall screwLocknutBearing pairCarriageBellows coverFloating-end supportHere: Cable carriersCable carrier
Ball-screw linear axisSchematic, not to scaleArrow: Cable carrier
Cable routing on linear modules and gantriesMachine tool feed axesRobot seventh axesCable routing along moving lift axesDress packs on six-axis robot arms (3D cable carriers)Transfer axes in cleanrooms (cleanroom cable carriers)Cable routing on rotary tables and axes (rotary cable carriers)

Related component entries: