Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.
ENGINEERING GUIDE
Selection and design guide
A plastic cable carrier uses linked reinforced-nylon segments to guide cables and hoses on a reciprocating axis. Choose bend radius and cavity from the cable data, calculate chain length from travel, and check unsupported span for the filled carrier.
01Construction and operating principle
A carrier consists of hinged links with side plates and crossbars or covers. Joint stops limit bending in one plane at a specified radius R. The fixed end attaches to the frame, and the moving end travels with the carriage. The bend moves along the chain between the upper and lower runs, holding the cables to the chosen bend geometry.
The carrier controls the cable bend path. Select a radius above the cables' dynamic requirements and allow the cables to move without rubbing, tangling or pulling on the ends. Cable selection and routing determine how well the installed system lasts.
Geometry of an unsupported cable carrier. MechWiki illustration based on the igus unsupported design guide.
Cable carrier components
Component
Function
Notes
Side plates
Carry weight and tension, and set bend radius
Reinforced nylon, commonly −40~+130 °C
Crossbars or covers
Form the cavity and retain the cables
Openable designs ease installation and maintenance.
Separators and shelves
Separate cables into compartments
Separate different cable sizes and cables from air hoses.
Brackets
Mount fixed and moving ends
Fixed or pivoting styles
Strain relief (clamps)
Restrain cables at the ends
Maintains cable length within the moving section.
Based on the igus unsupported design guide and industry reinforced-nylon carrier data.
02Types and size ranges
Configurations by construction and use
Open crossbar carrier
Openings between crossbars give ventilation and let operators see the cables. Crossbars can open on the inner or outer side.
Applications
Linear modules, gantries and general automation.
Selection tips
Set cavity height from the largest cable and width from the cable diameters. Use covers where there are chips or weld spatter.
JFLO catalog, J30Q.1.S series illustration
Enclosed carrier
Upper and lower covers enclose the cables against chips, weld spatter, dust and coolant.
Applications
Machine tools, welding, cutting and grinding.
Selection tips
At equal cavity height it is heavier and ventilates less, and may support a shorter free span. Choose openable covers for service.
JFLO catalog, J25F.1.S series illustration
Long-travel gliding carrier
The upper run glides over the lower one or in a guide trough. Rollers reduce sliding friction for heavy long-travel applications.
Applications
Gantry, crane and storage equipment with travel from tens to hundreds of meters.
Selection tips
Provide a guide trough. Use the manufacturer's gliding length and lowered moving-end height rules and check speed and acceleration.
igus catalog, P4 roller carrier
Low-noise, high-speed carrier
Short pitch and damped or flexible joints reduce vibration and noise.
Applications
Fast reciprocating axes, placement and inspection equipment, and noise-sensitive applications.
Selection tips
Check the load and unsupported span. igus E6.29 lists FLB at 1.75 m for a load of 3 kg/m.
igus E6.1 product page
Cleanroom carrier
Low-wear materials or flexible jointless bands limit particle generation.
Applications
Semiconductor, display, medical and laboratory equipment.
Selection tips
Check cleanroom certification, such as ISO Class 1. Band-style systems have short unsupported spans, about 1 m for e-skin SK28. Add support for longer runs.
igus catalog, e-skin cleanroom system
Three-dimensional robotic carrier
Round sections flex in several directions and allow torsion, with a retraction system to control slack.
Applications
Hose and cable packages on six-axis robot arms.
Selection tips
Select for the robot and bundle diameter. Use the manufacturer's torsion and retraction calculations.
igus triflex R TRC product page
Rotary carrier
Runs in an annular trough and travels through a defined angle in either direction.
Applications
Turntables, rotary axes and rotary workstations.
Selection tips
Size by angle and guide diameter using the supplier method.
igus twisterchain product page
Steel carrier
Galvanized or stainless side plates and aluminum or steel crossbars or rollers suit high loads, heat, chips and impact.
Applications
Heavy machine tools, metalworking and forging.
Selection tips
Include carrier weight in the drive load. Protect against corrosion outdoors or in damp areas.
TSUBAKI KABELSCHLEPP S/SX1802 product page
Product images are credited to JFLO, igus and TSUBAKI KABELSCHLEPP. Types follow manufacturer material and the steel-carrier section in Mechanical Design Handbook Part 21, Chapter 9, Section 4. Rotary and 3D layouts use their own manufacturer length calculations.
03Key parameters
Clearance for cables and hoses inside the carrier
Cable or hose
Minimum allowance relative to OD
Additional guidance
Round cable
10%
igus shows at least 1~2 mm clearance.
Flat cable
10%
Provide strain relief at both ends.
Pneumatic hose
5%~10%
Use 10% for rubber hose.
Hydraulic hose
20%
Pressure can lengthen and stiffen the hose.
Other media hose
15%~20%
—
From igus filling rules and industry selection notes. If d1 + d2 ≤ 1.2 times the cavity height, use a separator or shelf to prevent overlap. For similar cables sharing a compartment, keep height within 1.5 times the cable diameter. Above 0.5 m/s and 10,000 cycles per year, stacked cables need a shelf.
Approximate cable bend radius as a multiple of OD
Cable or hose type
Multiple
High-flex carrier cable (imported)
About 6~7.5
Domestic carrier cable
8~10
Pneumatic or water hose
10~12
Hydraulic hose
About 12
Steel carrier (handbook)
At least 10 times the largest hose or cable diameter
Industry selection notes, MechWiki carrier calculator and the SLE steel-carrier selection guidance in Mechanical Design Handbook Part 21. Use each cable's specified minimum moving bend radius and allow margin above the largest requirement. igus notes that a larger radius extends cable life.
Pitch. Small carriers about 20~30 mm. Medium carriers 45~65 mm. Shorter pitch improves smoothness and noise.
Speed and acceleration. One reinforced-nylon series lists 5 m/s, 5 m/s² and about 5,000,000 unsupported cycles. igus describes unsupported service life as generally at least 10,000,000 cycles. Ratings depend on the series.
Fill mass. ms = total cable mass / length, in kg/m. This value determines usable unsupported span.
04Unsupported span and sag
The upper run is supported by the chain's camber. A heavier fill or longer free span increases sag. Once the upper run touches the lower run, friction can wear out links and cables. Check unsupported span using cable mass after sizing radius and cavity.
Unsupported-length definitions
Designation
Meaning
When to use
FLG, straight unsupported length
Maximum span with the upper run essentially straight
Accurate positioning, high speed and acceleration, or where movement must stay stable
FLB, unsupported length with permissible sag
Maximum free span with some sag and no lower-run contact. Greater than FLG.
General applications
Above FLB
The upper run contacts the lower run.
Select a stronger series, use a guided gliding system, or add support rollers or a support plate.
FLG and FLB conventions follow igus and JFLO catalogs.
Plot cable mass per meter against required span on the selected series chart. Below the limit curve is usable. With the fixed end centered, the required unsupported span is about half the stroke plus any offset from center. Add the per-meter mass of each cable.
Unsupported-span examples from igus and JFLO catalogs
Manufacturer and series
Inner height, mm
Pitch, mm
Cable mass limit
Unsupported span
Source
igus E2.10
10.1
20
0.7 kg/m
FLB ≤ 0.75 m
igus printed page 42
JFLO J10Q.1
10
15
About 0.3 kg/m
Flat through 0.7 m, reaches zero near 1.0 m
JFLO page 3
igus E3.22
22
16.7
0.85 kg/m
FLB ≤ 1.2 m
igus printed page 54
igus E2/000 1400
21
33.3
2 kg/m
FLB ≤ 1.75 m
igus printed page 44
igus E4.21
21
30.5
4 kg/m
FLB ≤ 2.5 m
igus printed page 48
JFLO J25Q.1.S
25
46
About 6 kg/m
Flat through 1.2 m, reaches zero near 2.4 m
JFLO page 19
JFLO H30Q.1
30
46
About 4 kg/m
Flat through 1.2 m, reaches zero near 1.6 m
JFLO page 59
JFLO J30Q.1.S
30
46
About 8 kg/m
Flat through 1.4 m, reaches zero near 2.4 m
JFLO page 29
igus E2/000 2600
35
56
8 kg/m
FLB ≤ 2.75 m
igus printed page 44
igus E4.32
32
56
15 kg/m
FLB ≤ 3.3 m
igus printed page 48
igus E4.56
56
84
62.5 kg/m
FLB ≤ 5 m
igus printed page 48
JFLO J60Q.1.S
60
91
About 32 kg/m
Flat through 1.5 m, reaches zero near 3.5 m
JFLO page 45
The igus data are FLB values from the catalog overview. JFLO data are approximate chart readings. A similar cavity height can yield more than a twofold difference in span. Heavier fill reduces span. Filter by cable mass in the cable carrier tab of the wiring tool.
List the cables and hosesRecord OD, minimum dynamic bend radius and mass per meter for each cable and hose.
Choose bend radiusTake the largest cable requirement and round up to an available R.
Size internal height and widthAdd clearance to the largest diameter for height and to the side-by-side sum and separators for width.
Locate the fixed end and calculate lengthCenter it in the stroke for the shortest chain, or add the offset.
Check installation orientationCheck unsupported span for a horizontal run. Use a gliding guide trough if needed. Hanging, standing and side mounting have separate checks.
Set layout and strain reliefDistribute heavy cables symmetrically near the sides and use suitable end clamps.
R ≥ max(kᵢ · dᵢ), hi ≥ 1.1 · dmax, Bi ≥ 1.1 · Σd + separator thickness
R
Carrier bend radius, mm
kᵢ, dᵢ
Bend factor and outside diameter of each individual cable, mm for dᵢ
dmax
Largest cable outside diameter, mm, used to size the cavity
hi, Bi
Inner height and width of the carrier, mm
Σd
Sum of outside diameters in one row, mm
Use 1.2 for hydraulic hoses. In the industry example, five cables of 20, 30, 15, 20 and 15 mm use factor 1.15 for about 34.5 mm height and 115 mm width.
Lk = S/2 + ΔM + K, K ≈ π · R + 2T
Lk
Chain length, mm, round up to a whole link pitch
S
Travel, mm
ΔM
Fixed-end offset from the center of travel, mm
K
Extra length for the bend, mm. Use the series value or estimate πR plus two pitches.
T
Link pitch, mm
igus formula for straight travel with the fixed end near center. Use other manufacturer methods for rotary and most long gliding runs. For steel carriers, the Mechanical Design Handbook lists L = Ls/2 + πR + R.
H = 2R + HG (allow extra room for camber)
H
Installation height, mm
HG
Link outside height, mm
igus carriers can have factory camber that straightens when filled. Leave room above the unloaded run. Industry guidance suggests H = 2R + 1.2·HG.
Sag smaller than the carrier's minimum bend radius
Usable with speed and acceleration limits
Critical sag
Upper run noticeably sags toward the lower run
Major reduction of life, speed and acceleration
igus unsupported design guide. For long spans, use a guide trough for gliding operation or add carrier support.
Strain relief. Secure round cables at both ends unless the installation guide specifies moving-end-only restraint. For most cables, igus cites a distance of 10~30 cable diameters from bend to clamp.
Unreel without twist. Rotate the reel and lay cables straight before installation.
Balance the fill mass. Keep heavy lines toward the outer plates and light ones near the middle.
Allow each cable to move. No ties inside the moving portion. Only use end restraints as specified.
Guide long gliding runs. The upper run slides on the lower run in a trough. Some systems reverse about three links near the moving end. Follow the chosen series instructions.
07Failure modes and maintenance
Common failures and remedies
Symptom
Cause
Remedy
Broken conductors or jacket wear
Radius too small, unsuitable ordinary cable or crowded fill
Increase R, use continuous-flex cable and restore clearance.
Cable pulls out or bunches
Missing strain relief or internal ties
Use end restraint and leave the moving length free.
Upper run rubs on lower run
Excess unsupported span or fill weight
Use a higher capacity carrier or a guided gliding layout.
Cracked side plates or worn pin holes
Impact, lateral load, speed or temperature outside limits
Add guidance and follow speed and temperature limits. Change material or consider steel.
Carrier tips sideways
Narrow carrier with a large radius or unsupported vertical standing installation
Use a wider carrier, add guides, or reduce R only within all cable limits.
Crossbars pop off
Fill pushes covers outward
Choose a larger cavity.
Based on component reference notes, igus documentation and common selection and maintenance practice.
Inspect links for whitening or cracks, the upper run for increasing sag and cable jackets for wear at the bend. Replace damaged links as permitted by the manufacturer. Investigate routing and clearance before replacing a worn cable.
08Common design mistakes
Using the carrier radius alone. A carrier rated for R38 can still damage a cable that cannot accept R38.
Overfilling or stacking. Pressurized hoses can stiffen and squeeze cables. Use clearances and separators.
Tying cables together inside the moving chain. Each cable needs freedom to move under strain.
Omitting strain relief. Tension then acts on connectors, which can loosen.
Using unsupported installation for excessive spans. Contact between the runs wears links and cables.
Using ordinary cable. Repeated flexing can break the conductors. Use continuous-flex cables.
Sharing a compartment with pressurized hoses. A stiffened pneumatic or hydraulic hose can press on adjacent cables.
09Standards and manufacturer series
References and scope
Source
Scope
Mechanical Design Handbook, Part 21, Chapter 9, Section 4
TL and SLE steel-carrier sizes, length calculations and supports
igus e-chain design guidance
Length, fill, unsupported states and strain relief
UL94
Material flammability. One industry reinforced-nylon carrier example is rated HB.
Use manufacturer dimensions and ratings for engineering-plastic carriers.
igus. E2 series, E6/E6.1 low-vibration high-speed systems and fully enclosed carriers, with chainflex cables.
MISUMI and YIHEDA. Order by inner height and width and bend radius, with end brackets.
Common domestic plastic carrier designations list inner height, inner width and radius, for example 35.75.100.
JFLO cable carrier catalog ↗J and H series bend radii, pitch and load/span curves, appendix 2 FLG and FLB, and J30Q/J25F illustrations
igus E6.1, triflex R TRC and twisterchain series ↗Manufacturer images for low-noise, 3D and rotary types. triflex R TRC https://www.igus.com/product/triflex-TRC and twisterchain https://www.igus.eu/energy-chain/types/circular-movement/twisterchain-new-generation
Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-20
ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN
Buying and using: calculators, sellers, uses
The notes below are specific to this entry. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.
TOOLS / CALCULATE
Related selection calculators
Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.
The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. This entry also lists well-known makers; those outside the site directory are linked only when the official site was checked. Price comparison and ranking are not available yet.
igusPolymer cable carriers, continuous-flex cables and complete cable assemblies, with online sizing and 3D models.
Cable management on reciprocating slides, motion axes and moving tool heads.
Ball-screw linear axisSchematic, not to scaleArrow: Cable carrier
Cable routing on linear modules and gantriesMachine tool feed axesRobot seventh axesCable routing along moving lift axesDress packs on six-axis robot arms (3D cable carriers)Transfer axes in cleanrooms (cleanroom cable carriers)Cable routing on rotary tables and axes (rotary cable carriers)