COMPONENT / AC-SERVO-DRIVE

Ac Servo Drive

Ac Servo Drive · Leadshine
Manufacturer illustration · LeadshinePictured model: EL8-EC400FOriginal source
01 / INTRODUCTION

What is it?

A drive supplying controlled electrical power to a servo motor and executing motion commands.

02 / CONSTRUCTION

Construction & recognition

Must match the motor, feedback interface and controller communication. Appearance or rated power alone is insufficient for replacement.

03 / APPLICATIONS

Common applications

Servo positioning axes, automation equipment and robot control systems.

Browse this category

Image copyright belongs to the manufacturers or original authors. Brands and models identify illustrations; consult official documentation when selecting parts.

ENGINEERING GUIDE

Selection and design guide

Rectifies the AC supply into a DC bus and inverts it to drive the servo motor, with current, speed and position control loops inside. To select, choose the motor first and match the drive by current, set the command interface and electronic gear, decide whether an external regenerative resistor is needed, and after installation do inertia identification, gain tuning and notch filtering.

01Construction and how it works

The main circuit of a servo drive is rectifier → DC bus → inverter: the AC supply is rectified and filtered into a DC bus, and an IGBT inverter bridge outputs three-phase current to the motor using SVPWM (space vector pulse width modulation) (both the Delta ASDA-B2 and Leadshine L6N specification tables state SVPWM control). When the motor decelerates or is pulled down by a heavy load it becomes a generator, energy flows back into the bus and bus voltage rises; above a threshold the braking circuit dumps the energy into a regenerative resistor to be burned off.

The control part is three nested loops: the innermost current loop controls torque, the middle speed loop controls speed, and the outer position loop compares commanded position with encoder feedback, multiplying the error by the position gain to give the speed command. The faster the inner loops, the stiffer the outer loop can be tuned, so speed loop bandwidth is one of a drive's performance figures (Leadshine L8S series rated 3.5 kHz speed loop bandwidth, Delta ASDA-B2 rated up to 550 Hz speed control bandwidth; the two makers measure differently, so they cannot be compared directly). Part 23 of the Mechanical Design Handbook sums it up: a servo controller controls the motor in three ways, position, speed and torque, and its accuracy determines the accuracy of the whole servo system.

Leadshine L7EC-100S~1000S (EtherCAT bus type) connection to peripheral devices: single-phase 220 VAC supply → wiring circuit breaker (trips on overcurrent) → noise filter (prevents interference from the supply line) → magnetic contactor (switches servo power on/off) → drive L1C/L2C (control power) and L1/L2 (main power); regenerative braking resistor connected between P+ and Br; 24 VDC brake supply used when the motor has a brake; U/V/W/PE are the servo motor main circuit cable, PE the motor ground; CN2 encoder cable, CN3/CN4 EtherCAT in and out, CN1 I/O cable, CN5 divided pulse output, CN6 STO interface, Type-C port to PC commissioning software
Leadshine L7EC-100S~1000S (EtherCAT bus type) connection to peripheral devices: single-phase 220 VAC supply → wiring circuit breaker (trips on overcurrent) → noise filter (prevents interference from the supply line) → magnetic contactor (switches servo power on/off) → drive L1C/L2C (control power) and L1/L2 (main power); regenerative braking resistor connected between P+ and Br; 24 VDC brake supply used when the motor has a brake; U/V/W/PE are the servo motor main circuit cable, PE the motor ground; CN2 encoder cable, CN3/CN4 EtherCAT in and out, CN1 I/O cable, CN5 divided pulse output, CN6 STO interface, Type-C port to PC commissioning softwareImage source: Leadshine, AC Servo Systems General Catalogue (September 2026)
For selection of matching motors see their entries; the full servo motor sizing calculation is in the AC servo motor entryAc Servo Motor →Braked Low Voltage Servo Motor →Linear Motor →Direct Drive Torque Motor →

02Types and specification system

By command interface
InterfaceCommand methodMaker specification examplesCommon use
PulsePulse count sets position, frequency sets speed; three forms: pulse + direction, A/B quadrature, CW/CCW double pulseDelta ASDA-B2: differential 500 kpps (low speed) / 4 Mpps (high speed), open collector 200 kpps; Leadshine L7P-S: up to 4 MHzSingle or few axes controlled by a PLC
AnalogueVoltage corresponds to speed or torqueDelta ASDA-B2: 0 to ±10 VDC, input resistance 10 kΩTension and pressure control, position loop closed in the host
EtherCAT and other fieldbusesPosition, speed or torque sent cyclicallyLeadshine L6N: CSP, CSV, CST cyclic synchronous modes, PP, PV, PT profile modes, HM homing modeMulti-axis machines, motion controllers
RS485 / ModbusInternal positions plus communication triggerLeadshine L7P-S: RS485 communication, 16 built-in position commandsSimple point-to-point positioning

From Delta ASDA-B2 Series catalogue Specifications and the Leadshine AC Servo Systems General Catalogue L6N-S and L7P-S specification pages.

There are three control modes: position, speed and torque. Positioning axes on custom machines use position mode; screwdriving, winding/unwinding and press-fit pressure holding use torque mode; conveyor rollers and spindles use speed mode. Chapter 6 of the Inovance selection manual gives selection examples for both position and speed control; the method is the same, with position control adding a check of the electronic gear and droop pulses.

Current steps of 220 V drives (Leadshine L6N-S series example)
Rated powerRated output current ArmsMaximum output current ArmsRegenerative resistor
100 W1.24.8None built in, external possible
400 W3.59.5None built in, external possible
750 W5.516.6Built in
1000 W7.021.0Built in
1500 W9.531.1Built in
2000 W1236.0Built in

From Leadshine AC Servo Systems General Catalogue, L6N-S series specifications: only 750 W and above have a built-in regenerative resistor as standard, and all sizes can take an external one. Resistance and power of built-in resistors per the catalogue.

03Key parameters

Parameters to check when choosing a drive
ParameterMeaningValues and effect
Rated / maximum output currentCurrent available continuously and brieflyAt least the motor's rated and maximum current, or peak torque cannot be used
Main circuit supplySingle or three phase, voltage classDelta ASDA-B2 1.5 kW and below can use single-phase 200 to 255 VAC, 2 kW and 3 kW three phase only
Regenerative resistorResistance, power and processing capacity of the built-in resistorSee the method in "Selection steps"
Applicable load inertiaRange of load inertia the drive can tune stablyLeadshine L6N-S: less than 30 times motor inertia
Operating temperatureLeadshine L6N-S: 0 to 55 °CDerate above 45 °C
Altitude, vibrationLeadshine L6N-S: below 1000 m; vibration less than 0.5 g (10 to 60 Hz)Derate per the catalogue beyond these
Notch filtersSuppress mechanical resonanceLeadshine L6N-S: 3 sets, 50 to 4000 Hz; some series 4 sets, 50 to 8000 Hz
Dynamic brakingShorts the motor windings to dissipate energy and stop on fault or sudden power lossBuilt into Leadshine L6N-S; absent on some economy models
STOSafe torque off interfaceLeadshine L6N only on FS versions, standard on L7EC-S; the FESTO CMMS-AS listed in the handbook conforms to EN 61800-5-2

From Leadshine AC Servo Systems General Catalogue L6N-S and L7EC-S specifications, Delta ASDA-B2 Series catalogue, and Mechanical Design Handbook 23-488.

Leadshine L7EC-S drive interfaces: STO interface and divided pulse output at the top; on the front the display panel, Type-C commissioning port, CN1 general I/O interface (pin assignment in the table on the left: digital inputs 1 to 6, probes 1/2, digital outputs 1 to 3 positive and negative, built-in 24 V supply), EtherCAT ports and encoder interface; at the bottom the main power / regenerative resistor / motor power connector, ground terminal and encoder battery box slot
Leadshine L7EC-S drive interfaces: STO interface and divided pulse output at the top; on the front the display panel, Type-C commissioning port, CN1 general I/O interface (pin assignment in the table on the left: digital inputs 1 to 6, probes 1/2, digital outputs 1 to 3 positive and negative, built-in 24 V supply), EtherCAT ports and encoder interface; at the bottom the main power / regenerative resistor / motor power connector, ground terminal and encoder battery box slotImage source: Leadshine, AC Servo Systems General Catalogue (September 2026)

Position loop gain Kp and droop pulses: in position mode at constant speed, a number of pulses remain in the deviation counter, equal to the command pulse frequency divided by Kp. The larger Kp, the tighter the following, but with insufficient mechanical stiffness it oscillates. These droop pulses are worked off only when the axis stops, so Kp also sets the settling time after stopping.

ε = vs / Kp
ε
droop pulses in the deviation counter, pulse
vs
command pulse frequency, pps
Kp
position loop gain, 1/s

Inovance MS1-R Series Servo Motor Selection Manual section 6.1. Example: with vs = 25000 pps and Kp = 30 /s, ε = 833 pulse, which at 0.01 mm/pulse is a following lag of about 8.3 mm.

04Selection steps and calculation

  1. Choose the motor first, then match the drive by currentUse the maker's motor–drive matching table (chapter 1 of the Inovance selection manual is the matching list). Drive rated and maximum currents must be at least those of the motor; encoder protocols are not interchangeable, so mixing brands is essentially not feasible.
  2. Set interface and control modePulses from a PLC or a fieldbus; for pulses check the maximum frequency (open collector is usually only around two hundred kpps); where absolute encoders, full closed loop or gantry synchronisation are needed, confirm the drive supports them.
  3. Set electronic gear and command frequencyMake one command pulse correspond to a whole-number mechanical displacement, and check that command pulse frequency does not exceed the drive's limit.
  4. Decide whether an external regenerative resistor is neededCheck whether the drive has a built-in resistor and how many watts it can handle, then look at energy returned during deceleration and lowering.
  5. Safety circuitEmergency stop via STO plus contactor; for vertical axes match the brake output to the enable timing.
(PB / ΔL) × (B / A) = N_enc
PB
mechanical displacement per motor revolution (ballscrew lead), mm
ΔL
desired displacement per command pulse (position detection unit), mm/pulse
B/A
electronic gear ratio (numerator/denominator)
N_enc
encoder pulses per revolution

Inovance selection manual section 6.1. Example: lead 5 mm, required stopping accuracy ±0.01 mm, take ΔL = 0.01 mm/pulse, 500 command pulses per revolution; a 26-bit encoder gives 67108864 pulses per revolution, so B/A = 67108864/500. The Delta ASDA-B2 permitted electronic gear ratio is 1/50 < N/M < 25600 (catalogue text). The electronic gear changes only the command unit, not mechanical accuracy.

vs = 1000·VL / (60·ΔL)
vs
command pulse frequency, pps
VL
load speed, m/min
ΔL
position detection unit, mm/pulse

Inovance selection manual section 6.1: with VL = 15 m/min and ΔL = 0.01 mm, vs = 25000 pps. Under pulse control, vs must be below the limits of both controller output and drive input.

When a regenerative resistor is needed: decide in the three steps below.

  1. Check the drive's built-in capacitySmall drives often have no built-in resistor (Delta ASDA-B2 100 W and 200 W do not; Leadshine L6N-S below 750 W do not). Where there is one, the catalogue gives its processing capacity, such as 30 W for the Delta ASDA-B2 0.4 to 1.5 kW built-in resistor and 50 W for 2 to 3 kW.
  2. Calculate energy returned per decelerationUse the kinetic energy formula below to work out the energy released as motor and load decelerate from running speed to zero, which after friction losses enters the bus; on vertical axes the potential energy of the load is also returned when lowering, often far more than the kinetic energy. Multiplied by decelerations per minute, this gives average regenerative power.
  3. If exceeded, add an external resistor or change operating conditions firstInovance's order of measures: reduce the torque limit, lengthen deceleration time, lower maximum speed, and if the alarm persists add an external braking resistor; even with a built-in resistor, under some regenerative conditions the energy still exceeds its permissible loss and an external one is needed.
Ep = Jeq·(ω1² − ω0²) / 2
Ep
kinetic energy released by rotating masses during deceleration, J
Jeq
total inertia referred to the motor shaft (motor + load), kg·m²
ω1, ω0
angular speed at start and end of deceleration, rad/s, ω0 = 0 for a full stop

Mechanical Design Handbook table 7-4-2 (braking torque calculation, load torque term for horizontal braking). Used to estimate the upper limit of returned energy; what actually enters the bus is less after friction and motor copper losses.

Built-in regenerative resistors and minimum permissible resistance (Delta ASDA-B2 example)
Drive kWBuilt-in resistanceBuilt-in resistor powerBuilt-in processing capacityMinimum permissible resistance
0.1, 0.2———60 Ω
0.4, 0.75100 Ω60 W30 W60 Ω
1.0, 1.540 Ω60 W30 W30 Ω
2.0, 3.020 Ω100 W50 W15 Ω

From Delta ASDA-B2 Series catalogue, Selection of Regenerative Resistor. On ALE05 regeneration error, increase resistor capacity or reduce resistance, but never below the minimum permissible resistance; with several resistors in parallel the total must also not be below it. For other brands follow their manuals.

  1. Inertia identificationJog with no load or with load so the drive learns the load inertia ratio.
  2. Choose stiffness level, auto-tuneThe Leadshine L6N has one-key auto-tuning and stiffness parameters; start at low stiffness and step up, backing off one or two levels when vibration or squealing appears.
  3. Suppress resonanceFind the resonance frequency from the speed waveform or spectrum and set a notch filter; for timing belts and long cantilever tip sway use vibration suppression.
  4. Add feedforward to shorten settlingSpeed feedforward reduces following lag; too much causes overshoot.
  5. Export parameters for the recordImport them directly when replacing the drive.
Size the motor first with the ballscrew servo calculator, then match the drive once the motor is chosenPower, torque and speed conversion

05Installation, adjustment and use

Wiring and grounding points
ItemPracticeSource
Main circuitCircuit breaker → noise filter → magnetic contactor → drive L1/L2(/L3)Leadshine connection diagram
External regenerative resistorL7EC-100S~1000S between P+ and Br; 1.5 kW and above between P+ and B2, removing the B1/B2 jumperLeadshine connection diagram
Brake supplySeparate 24 VDC supply; the drive's built-in 24 V supply must not be used for the motor brakeLeadshine wiring diagram
FieldbusCat 5e double-shielded network cableLeadshine wiring note 1
Encoder divided outputTwisted shielded cable, shield connected to PE at both ends, GND reliably connected to the host signal groundLeadshine wiring note 3
DO outputsUser-supplied 12 to 24 V, each point maximum 30 VDC, 50 mALeadshine wiring note 2
STOWhen using STO remove the jumper and connect to the safety switchLeadshine wiring diagram
Motor groundThe PE terminal is the motor ground terminal and must be connectedLeadshine connection diagram

Terminal names differ between brands; wire per the manual of the drive used.

  • Mount the drive vertically in the cabinet with ventilation space above and below; derate per the catalogue above 45 °C in the cabinet.
  • Route power cables, encoder cables and signal cables separately, not bundled together.
  • Before power-up confirm motor direction, limits and home; jog with no load before connecting the load.
  • Bus capacitors stay charged after power-off; wait until the indicator goes out before disconnecting wires.

06Failure modes and maintenance

Common alarms, causes and remedies
AlarmMain causesRemedy
OvervoltageDeceleration too fast, large inertia ratio, vertical lowering; too much regenerative energyLengthen deceleration, lower maximum speed, add or enlarge the regenerative resistor
Regenerative braking error / braking rate too highRegenerative resistor not connected, wrong resistance or power, jumper not removedChoose the resistor per the catalogue, check the B1/B2 jumper
Undervoltage / phase lossInsufficient supply capacity, loose wiringCheck supply and terminals
OvercurrentU, V, W short-circuited or grounded, drive damagedPower off and measure insulation, replace cables
OverloadRMS torque above rated, mechanical jamming, brake not releasedRecalculate Trms, check mechanics and brake
Excessive position deviationLow gain, acceleration too high, load jammed, insufficient peak torqueRaise gain or slow acceleration, check mechanics, check drive maximum current
Encoder feedback errorCable broken, interference, low batteryCheck shielding and grounding, replace cable or battery
OverheatingHigh cabinet temperature, failed fanImprove ventilation, derate for temperature

Alarm types from the Leadshine L6N-S alarm function list (overvoltage, undervoltage, overcurrent, overload, overheating, overspeed, main supply phase loss, regenerative braking error, excessive position deviation, encoder feedback error, braking rate too high, travel limit exceeded, EEPROM error) and Delta ALE05; causes and remedies are a general compilation.

Maintenance: clean fans and heat sinks regularly; on multiturn absolute systems keep the drive powered while changing the battery; record parameter changes, and when problems arise compare parameters first.

07Common design mistakes

  • Matching the drive by power instead of current. With drive maximum current below the motor's, the motor's peak torque cannot be used and position deviation alarms occur during acceleration.
  • Not calculating regeneration on vertical axes. Potential energy is all returned when lowering; small drives without built-in resistors trip on overvoltage as soon as they run.
  • External resistor fitted without removing the jumper, or resistance below the permissible minimum. The braking transistor fails from overcurrent.
  • Powering the brake from the drive's built-in 24 V. Leadshine explicitly forbids this; brake current drags down the control supply.
  • Signal and power cables in the same trunking. Pulses are disturbed and position drifts gradually, which checking the mechanics never finds.
  • High speed on open-collector pulses. Delta open collector is only 200 kpps; with a fine electronic gear and high speed the pulse frequency is insufficient, so use differential or a fieldbus.
  • The higher the gain the better. With insufficient mechanical stiffness high gain causes squealing; do inertia identification and notch filtering first, then raise stiffness.
  • Emergency stop by removing servo enable only. Enable is not a safety circuit; where personnel safety is involved use STO and design to safety standards.

08Related standards and maker series

Standards cited in the sources
StandardSubjectSource
EN 61800-5-1, UL 61800-5-1Adjustable speed electrical power drive systems, safety requirements (electrical, thermal and energy)Inovance selection manual chapter 7
EN 61800-3Adjustable speed electrical power drive systems, EMC requirementsInovance selection manual chapter 7
EN 55011Radio disturbance limits for industrial equipmentInovance selection manual chapter 7
EN 61800-5-2Adjustable speed electrical power drive systems, functional safety requirementsMechanical Design Handbook 23-488 (FESTO CMMS-AS)
ISO 13849-1Safety of machinery, safety-related parts of control systemsMechanical Design Handbook 23-488

Use the current edition.

  • Inovance: SV630, SV660, SV670, SV680 series (matched to MS1-R motors by encoder).
  • Leadshine: L3, L5, L6, L7, L8 single-axis drives, 2L3/2L5/2L6 dual-axis, 4LF7EC/6LF7EC multi-axis, L6EC-L and L8ECL-S direct drive drives.
  • Delta: ASDA-B2 and other series.
  • FESTO: CMMS-AS (listed in part 23 of the Mechanical Design Handbook).

—Sources

  • Leadshine, AC Servo Systems General Catalogue (September 2026, Chinese) ↗Product positioning page (speed loop bandwidth, encoder bits); L7EC-S peripheral connection diagram and interface description; L7P-S wiring diagram (4 MHz pulses, STO, wiring notes); L6N-S specifications (current steps, regenerative resistor configuration, applicable load inertia, dynamic braking, notch filters, one-key auto-tuning, alarm functions, operating environment)
  • Delta, AC Servo Drive & Motor ASDA-B2 Series catalogue (English, 2021-10) ↗Selection of Regenerative Resistor (built-in resistor specifications, minimum permissible resistance, ALE05 handling); Specifications (supply, SVPWM, pulse types and frequency, electronic gear ratio range, analogue input, speed bandwidth); Wiring notes
  • Inovance, MS1-R Series Servo Motor Selection Manual B05 (Chinese) ↗Chapter 1 motor and drive matching list; section 3.5 overvoltage, overload and braking resistor when the permissible inertia ratio is exceeded; section 6.1 position control selection example (electronic gear, command pulse frequency, droop pulses in the deviation counter); chapter 7 certification standards
  • Mechanical Design Handbook, part 23: Pneumatics, chapter 11, 5.1 Servo motor controllersPrinted page 23-488: three control methods, CMMS-AS conforming to EN 61800-5-2 and ISO 13849-1
  • Mechanical Design Handbook, part 7: Shafts and their connections, chapter 4: Brakes, 2.2 Determining braking torquePrinted page 7-364: table 7-4-2 braking torque calculation (kinetic energy term of rotating masses)
  • Industry selection and calculation material (compiled)Servo commissioning notes: order of inertia identification, stiffness adjustment and resonance suppression

Tables and formulas are rearranged from the sources above. Verify against the current standard and the manufacturer catalogue before finalising a design. Updated 2026-11-17

ONLY ON MECHWIKI / SELECT · BUY · MAINTAIN

Buying and using: calculators, sellers, uses

The notes below cover the “Motor drives” category. MechWiki prepared these category notes from public standards and engineering references. Use the selected manufacturer’s catalog for ratings, life factors and dimensions.

TOOLS / CALCULATE

Related selection calculators

Use these calculators for a preliminary estimate, then verify the result against this entry, the manufacturer catalogue and installation limits. Results do not replace a specific model rating.

07 / SELLERS

Who sells it

The directory links to manufacturer selection and CAD resources and identifies the maker of the pictured example. Check stock and lead time with the supplier. Price comparison and ranking are not available yet.

Corresponding series by manufacturer

ManufacturerSeriesOfficial product page
Panasonic IndustryMINAS A6(A6S / A6N / A6B)Open product page
InovanceSV660NOpen product page
SiemensSINAMICS V90Open product page
BeckhoffAX5000Open product page

Representative series and official product pages; a manufacturer may offer other suitable series. Product ranges, availability and applicability are governed by manufacturer information. This is not a ranking, recommendation or equivalence judgment.

08 / WHERE IT IS USED

Typical uses & where it sits in machines

Servo positioning axes, automation equipment and robot control systems.

Cabinet doorEnclosure & panelPSU & breakersPLC & HMISafety relayRelays & terminalsFan & filterE-stopPilot lightsHMIHere: Motor drivesServo drives
Control cabinet (door and mounting panel)Schematic, not to scaleArrow: Servo drives
Servo and stepper axis controlSynchronised multi-axis machinesFieldbus-connected production linesMachines requiring drive safety functions

Equipment breakdowns on this site that use this component family: