Column Buckling Calculator

Estimate the axial buckling load from material stiffness, cross-section, unsupported length and end restraints.

Loading the calculator…

How to use the calculator

  • A 1000 mm pinned–pinned column with a solid 40 × 60 mm section, E = 206 GPa and yield strength 235 MPa has a slenderness of about 86.6. The parabolic model gives a critical load of about 441.8 kN before the safety factor.