What it does
Manages hot runner heating zone by zone so manifolds and nozzles stay at temperatures suited to resin flow.
How it works
Thermocouples in each heating zone report actual temperature, and the controller compares it with setpoint and adjusts that zone's heater power. Temperature stability depends on the algorithm and also on sensor position, heaters and heat loss paths; measurement interference makes the controller act on wrong data.
Process sequence
- Confirm zones match circuits
- Set temperatures the material needs
- Heat up under control
- Compare feedback and adjust power
- Hold and monitor for faults
- Cool and shut down per the process
Key inputs
- Resin processing window
- Zones and heater loads
- Thermocouple type and mapping
- Power supply and permission interface with the moulding machine
Common problems
- Miswired or noisy thermocouples giving wrong feedback
- Heater faults pulling zones off target
- Zone numbers mismatched
- Different heat losses making manifold temperature uneven
Limits of application
- The controller handles hot runner heating, unlike water or oil mould temperature units
- Manual output cannot replace valid temperature feedback
- Wiring and heat-up requirements follow the matching equipment
Functional modules
Zone temperature sensing
Reads thermocouple signals
Temperature control
Calculates each zone's power demand
Power output
Drives the matching heaters
Alarms and HMI
Show deviations and faults
Manufacturer & technical sources
Continue with manufacturer product pages, operating principles and technical information for this equipment type.