What it does
Integrates material condition checks into the line, either by indentation or by electromagnetic comparison related to hardness.
How it works
Taking eddy current or magnetic induction comparison as an example, an AC coil induces eddy currents in the conductive part, and changes in conductivity, permeability and microstructure affect the received signal. The instrument compares each part's signal with a range set from known reference parts to screen heat treatment condition or mixed material; the signal cannot be read directly as a general hardness value.
Process sequence
- Prepare representative reference parts
- Confirm position and test conditions
- Set the acceptance range
- Pass parts through the coil or probe area
- Compare signals and sort
- Periodically recheck references and process changes
Key inputs
- Material grade and heat treatment
- Representativeness of reference parts
- Geometry and test position
- Temperature, surface and threshold validation
Common problems
- Geometry or position changes confused with hardness changes
- Reference parts not covering normal variation
- Temperature and material differences causing misjudgment
- Using only good samples without verifying separation of bad ones
Limits of application
- Electromagnetic comparison is not direct Vickers or Rockwell indentation measurement
- Each material and shape needs the relationship revalidated
- In-line indentation equipment must also consider indenter load and indent reading
Functional modules
Test coil or probe
Excites and receives the material response
Part locating and conveying
Holds the test position
Signal processing and reference range
Compares material condition
Sorting and traceability
Outputs results and abnormal positions
Manufacturer & technical sources
Continue with manufacturer product pages, operating principles and technical information for this equipment type.