What it does
Detects surface and near-surface discontinuities in conductive materials and can distinguish material conditions under calibrated settings.
How it works
An AC coil produces a changing magnetic field that induces eddy currents in the conductive part; cracks or changes in conductivity or permeability alter the response, and the instrument analyses signals such as coil impedance. Signals are also affected by probe lift-off and part geometry.
Process sequence
- Select probe and frequency
- Calibrate on reference parts
- Scan along the path
- Analyse the response
- Record or sort
Key inputs
- Material conductivity and magnetism
- Target defect depth and orientation
- Probe gap and surface condition
Common problems
- False calls need separating into lift-off, geometry and material effects
- No alarm does not mean all deep defects are absent
Limits of application
- Conventional eddy current mainly suits conductive materials and has limited depth
- It cannot substitute for ultrasonic volumetric inspection
Functional modules
Excitation and probe
Create the field and sense the response
Scanning and positioning
Control relative position of probe and part
Signal analysis
Reads features such as amplitude and phase
Reference parts and sorting
Set the comparison basis and organize output