How to size an industrial shock absorber
Add the kinetic energy at contact and the work done during the absorber stroke. Check the selected model's limits for each impact, hourly duty, effective mass and impact speed.
Worked example for a horizontal stop with thrust
E1 = m·v²/2 = 6.25 J. E2 = F·S = 12.50 J. E = 18.75 J.
A moving mass of 50 kg reaches the stop at 0.5 m/s. The drive continues to apply 500 N during the 25 mm stroke. One absorber must take 18.75 J per impact. At 600 impacts per hour, its demand is 11,250 J/h. At that impact speed the effective mass is 150 kg.
An individual impact rating is one check. Also verify hourly duty, impact speed and the effective mass range at the expected operating conditions. Only divide the energy by the number of absorbers if the assembly actually shares the load.
Vertical drops and rotary stops
Free fall: E1 = m·g·H, E2 = m·g·S. Rotation: E1 = J·ω²/2, v = ω·Rs.
For a 10 kg mass falling 200 mm with a further 25 mm downward stroke, the absorber takes about 22.06 J per impact. Speed at contact is about 1.98 m/s. Gravity adds work throughout the stopping stroke.
Use the mass moment of inertia for rotary kinetic energy. For effective mass, use linear speed at the absorber's contact point. Check side load and permitted impact angle, as well as any torque that remains after stopping.
Check duty and mounting before choosing a model
Eh = E·N. me = 2·E/v².
Use the catalogue's energy and frequency data for the selected model and expected temperature. Check allowable reaction load with the manufacturer's data. The tool's estimate of 1.2·E/S depends on the assumed stopping characteristic.