Hydraulic Reservoir Heat Balance Calculator

Estimate hydraulic system heat loss, natural heat rejection from the reservoir and the resulting oil temperature rise.

Loading the calculator…

How to use the calculator

  • A 4 kW pump input and 80% system efficiency leave 0.8 kW as heat. With a 300 L reservoir and a 15 W/(m²·°C) heat-transfer coefficient, estimated equilibrium temperature is 48.3 °C at 30 °C ambient.