Shaft Coupling Sizing Calculator

Calculate coupling design torque and check the selected torque and speed ratings. Confirm bore sizes and allowable shaft misalignment in the catalogue.

Loading the calculator…

How to use the calculator

  • At 2.2 kW and 1,450 r/min, nominal torque is 14.49 N·m. A service factor of 1.5 gives a design torque of 21.73 N·m.